Tank Intelligence - Rosemount TankRadar
Tank Intelligence - Rosemount TankRadar
Tank Intelligence - Rosemount TankRadar
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
uses, such as Foundation fieldbus and Profibus, via our<br />
proprietary TRL/2 bus, or by emulation of other vendors’<br />
fieldbuses.<br />
Via the fieldbus, the gauge is connected to a Field Communication<br />
Unit (FCU), which continuously polls and stores<br />
tank content data from groups of radar tank gauges, and<br />
DAUs. The FCU delivers tank content data to the <strong>Rosemount</strong><br />
<strong>Tank</strong>Master inventory management software. This ensures<br />
that the system is continuously updated with fast and reliable<br />
tank data.<br />
If you prefer, data can also be delivered directly to your<br />
DCS/SCADA system or plant host computer via various<br />
protocols.<br />
Wireless installation<br />
The <strong>Rosemount</strong> <strong>Tank</strong> Gauging system offers different<br />
options for wireless communication: between each tank and<br />
the control room, or between the FCU and <strong>Tank</strong>Master.<br />
<strong>Tank</strong>Radar Rex and Pro gauges support Emerson’s Smart<br />
Wireless concept. It utilizes self-organizing (mesh) networks<br />
to ensure that your measurement information will always be<br />
available. Self-organizing networks automatically optimize<br />
connectivity to achieve the highest data reliability.<br />
Unlike other approaches to in-plant wireless, which<br />
require direct line-of-sight between the instrument and the<br />
communication gateway, Emerson’s Smart Wireless concept<br />
ensures maximum network integrity by allowing devices<br />
to communicate with each other. Every device serves as<br />
a network connector, which means there is no single point<br />
of failure.<br />
Should a temporary obstruction block a direct connection,<br />
the network automatically reroutes the signal to an adjacent<br />
device, ensuring network reliability and data integrity.<br />
5