lokring connections
lokring connections
lokring connections
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
LEAK DETECTION METHODS<br />
LEAK DETECTION USING TRACER GAS<br />
ADVANTAGES OF LEAK DETECTION USING TRACER GAS<br />
During tracer gas leak detection, the empty air-conditioning<br />
system is charged with commercially available tracer gas. Any<br />
escaping gas is traced by a leak detection unit especially developed<br />
for the application.<br />
No cross sensitiveness to other gases.<br />
On account of the small molecule size, even the tiniest of<br />
leaks can be found<br />
The evaporator can easily be checked through the ventilation<br />
slots in the passenger compartment.<br />
Thanks to the straightforward and reliable method, you save<br />
valuable time on every leak detection.<br />
LOKBOX: TLD.500 | Tracer gas leak detection set<br />
LOKBOX tracer gas leak detection set<br />
This set contains all you need for leak detection<br />
using tracer gas in a sturdy plastic case.<br />
Scope of supply<br />
Tracer gas leak detector LOKtracer 500<br />
Tracer gas pressure regulator PR-TG<br />
1-valve manifold with gauge<br />
Connecting hoses<br />
Quick coupler (red)<br />
Article no. Article name Description<br />
L13004583 LOKbox TLD.500 Tracer gas leak<br />
detection set<br />
LOKTOOL: LOKTRACER 500 | Tracer gas leak detector<br />
LOKTOOL tracer gas leak detector<br />
The LOKTRACER 500 was especially developed for tracer gas leak<br />
detection in vehicle air-conditioning systems. The unit reacts<br />
exclusively to tracer gas, so that cross sensitiveness to other gases<br />
can be almost completely excluded. The extra-long and highly<br />
flexible measuring probe also allows components in the engine<br />
compartment which are difficult to access to be checked. The size<br />
of the leak is indicated by 3 LEDs.<br />
Green LED: No leak<br />
Yellow LED: Leak > 1.4 g/year<br />
Red LED: Leak > 14 g/year (major leak)<br />
The intermediate range is indicated by an increasingly loud<br />
acoustic signal (can be switched off).<br />
Article no. Article name Description<br />
L14003015 LOKtracer 500 Tracer gas leak detector<br />
Technical data<br />
Sensitivity<br />
< 1 g/year<br />
Response time<br />
< 1 sec.<br />
Warm-up time<br />
< 2 min.<br />
Measuring probe<br />
500 mm<br />
Working range –15 °C – 40 °C<br />
Voltage supply<br />
4 x mignon cell LR6/AA 1.2 V<br />
L x W x H in mm 70 x 100 x 28<br />
Weight<br />
154 g<br />
VULKAN LOKRING