MEASURING AND DIAGNOSIS DEVICES<br />
FOR REFRIGERANT ANALYSIS<br />
LOKTOOL: DSG.600 | Air-conditioning diagnosis sight glass<br />
LOKTOOL air-conditioning diagnosis sight glass<br />
This sight glass guarantees you insight into the air-conditioning<br />
system for the first time. You can make up to 100 ml refrigerant<br />
visible and thus evaluable in the sight glass.<br />
Article no. Article name Description<br />
L13004594 LOKtool DSG.600 Air-conditioning diagnosis<br />
sight glass<br />
The following tests can be carried out:<br />
Miscibility of the oil<br />
Oil quantity (to a certain extent)<br />
Humidity share<br />
UV dye quantity (to a certain extent)<br />
Chips and other external material<br />
Technical data<br />
Capacity<br />
ca. 100 ml<br />
Max. operating pressure<br />
25 bar<br />
Working range 10 °C – 49 °C<br />
Length<br />
230 mm<br />
Weight<br />
1 kg<br />
Scope of supply<br />
Quick coupler (red)<br />
Quick coupler (blue)<br />
Service hose (red)<br />
Service hose (blue)<br />
LOKTOOL: GA500PLUS | Refrigerant analysis device<br />
LOKTOOL refrigerant analysis device<br />
The share of air-conditioning systems with contaminated<br />
refrigerant is increasing all the time. This is why it is important<br />
to check the purity of the refrigerant before every recovery process,<br />
in order to protect your refrigerant supply and thus your<br />
customers’ air-conditioning systems from contaminated refrigerant.<br />
The GA500Plus determines the degree of purity of R12,<br />
R22 and R134a quickly and easily. The result measured can be<br />
printed out and presented to the customer.<br />
Scope of supply<br />
Article no. Article name Description<br />
L14001200 LOKtool GA500Plus Refrigerant analysis device<br />
L14001851 NT-GA500Plus 230 V mains adapter for<br />
LOKtool GA500Plus<br />
Technical data<br />
Accuracy + 1 %<br />
Resolution 0.1 %<br />
Measurement time<br />
< 60 Sek.<br />
Working range 10 °C – 49 °C<br />
12 V connection for the vehicle battery<br />
Connection hose<br />
Quick coupler for R134a air-conditioning systems<br />
Quick coupler for R12 air-conditioning systems<br />