<strong>NSF</strong>/<strong>ANSI</strong> <strong>St<strong>and</strong>ard</strong> <strong>46</strong><br />

• Ultraviolet disinfection devices<br />

– Performance <strong>and</strong> evaluation<br />

• UV disinfection test<br />

– Criteria (<strong>46</strong>)<br />

» Individual fecal coliform effluent samples not to<br />

exceed 200 organisms/100 mL<br />

» All components designed to be exposed to wastewater<br />

<strong>and</strong> UV light shall be resistant to UV attack, corrosion<br />

<strong>and</strong> structural deformation<br />

385 - Geometric mean <strong>of</strong> all required effluent samples<br />

collected in final 10 weeks must meet the pass/fail<br />

criteria:<br />

» fecal coliform ≤ 200 organisms /100 mL<br />

» E. coli ≤ 126 organisms /100 mL<br />

» Enterococci ≤ 35 organisms /100 mL