02.01.2015 Views

Basic Concrete w/Poured Beams - BlazeFrame

Basic Concrete w/Poured Beams - BlazeFrame

Basic Concrete w/Poured Beams - BlazeFrame

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Project Submittal –<strong>Basic</strong> <strong>Concrete</strong> w/<strong>Poured</strong> <strong>Beams</strong><br />

DT3 - Wall Centered Under Beam Overlap Mineral Wool<br />

Joint Movement Capabilities (MC) / Profile Series design based on UL: HW-D-0498 & 0499<br />

1/2” up to 4" MC - (Stock Series)<br />

"Double Tee"<br />

<strong>Concrete</strong> Deck<br />

Fastener Attachment 24" O/C max.<br />

<strong>BlazeFrame</strong> Composite<br />

Track/Fire Stop<br />

Inverted between Substrate<br />

and Deflection Track<br />

Min. 4 pcf Mineral Wool<br />

Compress 33% between<br />

<strong>Concrete</strong> Flange and <strong>BlazeFrame</strong><br />

Deflection Track<br />

1" to 4"<br />

(See Notes)<br />

5/8" Type X<br />

Gypsum Wallboard<br />

Steel Stud<br />

Max 24" O/C<br />

1. Deflection (compression only) = Install gypsum to cover <strong>BlazeFrame</strong> profile<br />

2. Deflection (compress + extension) = Install gypsum ½ of MC requirement above <strong>BlazeFrame</strong><br />

3. Attach to substrate with approved fastener max 24” O.C or per E.O.R.<br />

4. Do not screw drywall or stud to <strong>BlazeFrame</strong> profile<br />

5. Min. 4 pcf mineral wool compressed 33% between substrate flange and <strong>BlazeFrame</strong><br />

6. Drywall fasteners 1” to 4" below Deflection Track to accommodate MC<br />

UL, ASTM & Code Standards<br />

Leed Points<br />

UL2079 & ULC S115-M95<br />

MR 2.1 & 2.2 - Construction Waste: up to 2pts<br />

ASTM E814, E1966, E2837<br />

MR 4.1 & 4.2 - Recycled Content: up to 2 pts<br />

A1003, A653, A924, C645, C754, C955 MR 5.1 & 5.2 - Regional Proximity<br />

AISI 2004 NAS<br />

EQ 4.1 - Low Emitting Materials<br />

2009 IBC & 2010 CBC EQ 9 - Enhanced Acoustical<br />

Phone: (425) 869-2811 Fax: (425) 869-2300<br />