gas chromatography<br />

Preconfigured SRI <strong>GC</strong>s<br />

Enjoy the Convenience of Ordering a System<br />

Already Optimized for Your Application<br />

Preconfigured <strong>GC</strong>s are designed with inlet systems,<br />

detectors, and accessories required for a specific application.<br />

The preconfigured <strong>GC</strong>s are also supplied with an internal data<br />

acquisition system and PeakSimple for Windows ® software<br />

to control the <strong>GC</strong> and acquire and analyze the data.<br />

Educational <strong>GC</strong> – 310 Chassis<br />

Gasless with CCD (built-in air compressor)<br />

• Standard on-column injector<br />

• Detects combustible (hydrocarbon) molecules<br />

• Packed <strong>GC</strong> column included<br />

Multiple Gas Analyzer—8610C Chassis<br />

Separates H2, O2, N2, CH4, CO2, and Hydrocarbons.<br />

Model 1—Fixed Gases and C1 to C6 Hydrocarbons<br />

• Two columns—MoleSieve 13x and silica gel<br />

• Sensitivity for CO and CO2 to ppm level<br />

• 10-port gas sampling automatic valve and loop<br />

Model 1—Multiple Gas Analyzer<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

Model 1 with TCD Single Channel 8610022 8610512<br />

Model 1 with TCD/FID* 8610023 8610513<br />

Model 1 with TCD/HID* 8610501 8610514<br />

*Four-channel PeakSimple data system.<br />

Model 310 with CCD<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

Gasless with CCD with cooling 31001105 310502<br />

Gasless with CCD without cooling 8611252 8611305<br />

TCD System (fast and manual cool down)<br />

• Universal detector sensitive from 100% to 200ppm<br />

• Can analyze room air, human breath<br />

• Packed <strong>GC</strong> column included<br />

Model 310 with TCD<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Model 310 with TCD 8610001 310501<br />

Models 1 and 2 Plus Sulfur<br />

Multiple gas and sulfur analysis in one unit. Detects low sulfur<br />

concentrations.<br />

• TCD, FID-methanizer and FPD/FID detectors<br />

• Uses just one gas sampling valve with Silcosteel ®<br />

• 2-meter MoleSieve and silica gel columns<br />

• 60-meter capillary column<br />

• Built-in air compressor<br />

• Four-channel PeakSimple data system<br />

Models 1 and 2 Plus Sulfur—Multiple Gas Analyzer<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Model 1 Plus Sulfur 8611271 8611325<br />

Model 2 Plus Sulfur 8611274 8611307<br />

gc instruments<br />

FID System<br />

• Carrier and combustion gas<br />

• Packed <strong>GC</strong> column included<br />

Model 310 with FID<br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Model 310 FID with cooling 8611251 8611306<br />

Basic Capillary FID <strong>GC</strong>—8610C Chassis<br />

• Hydrocarbon selective from 100% to 1ppm<br />

• Built-in air compressor<br />

• 30-meter x 0.53mm capillary column included<br />

Basic Capillary FID <strong>GC</strong><br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Basic Capillary FID <strong>GC</strong> 8610523 8610524<br />

Model 2 Fixed Gases and C1 to C20 Hydrocarbons<br />

• Heated 10-port gas sampling valve (electrically actuated)<br />

• Column switching<br />

• Also measures water and alcohol<br />

• Two packed <strong>GC</strong> columns<br />

Model 2—Multiple Gas Analyzer<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Description<br />

Model 2 with TCD 8610503 8612232<br />

Model 2 with TCD/FID/Methanizer 8610504 8612233<br />

Model 2 with TCD/HID 8611273 8610514<br />

Sulfur <strong>GC</strong>—8610C Chassis<br />

For the analysis of H2S in natural gas, total reduced sulfur<br />

analysis, mercaptans, and sulfur containing pesticides.<br />

• FID/FPD combination detector<br />

• Built-in air compressor<br />

• 1-meter PTFE Hayesep ® D column<br />

• 10-port gas sampling valve with nickel loop<br />

• Four-channel PeakSimple data system<br />

Sulfur <strong>GC</strong><br />

Description<br />

110V<br />

Part No.<br />

220V<br />

Part No.<br />

Sulfur <strong>GC</strong> 8610525 8610517<br />