GC - Teknolab AS
GC - Teknolab AS
GC - Teknolab AS
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
gas chromatography<br />
gc instruments<br />
SRI Inlet Systems<br />
Every SRI <strong>GC</strong> is equipped with an unheated on-column inlet<br />
system. On a Model 310 chassis, you can replace that with<br />
any one of the other four inlet systems available—headspace,<br />
split/splitless, purge and trap, and flash. On a Model 8610C<br />
chassis, you can mount any of the inlet systems to a total<br />
of five.<br />
On-Column Inlet Systems<br />
Suitable for 0.53mm capillary and 1/8" packed columns.<br />
Includes EPC carrier gas controller and molecular sieve filter.<br />
On-Column Inlet Systems<br />
Description<br />
Part No.<br />
Additional On-Column Injector 8690023<br />
Heated Static Headspace Inlet System<br />
Ideal for the analysis of volatiles, especially where the sample<br />
matrix is dirty. Sample is heated and injected via a sample<br />
loop and gas sampling valve. Vial sleeve can be heated to<br />
90°C. Requires 10–20mL of sample for operation.<br />
Heated Static Headspace Inlet Systems<br />
Description<br />
Part No.<br />
Heated Static Headspace Injector 8690045<br />
SRI Detectors<br />
The SRI <strong>GC</strong> allows you to choose the detector(s) you want<br />
installed. The chassis can accommodate as many as four<br />
detectors to give you maximum flexibility.<br />
Table 1 – Detector Specifications<br />
Detector Selectivity Sensitivity (Approx.)<br />
CCD Hydrogen and hydrocarbons 500ppm<br />
TCD Universal 200-500ppm<br />
FID Hydrocarbons 1ppm<br />
DELCD Chlorinated and brominated 10ppb<br />
molecules<br />
FID/DELCD Hydrocarbons, chlorinated and 10ppm<br />
brominated molecules<br />
HID Universal with exception of neon 10ppm<br />
PID<br />
Aromatics and molecules with double 10ppb<br />
carbon bonds<br />
NPD Nitrogen and phosphorus 10ppm<br />
NPD/DELCD Nitrogen, phosphorus, chlorinated 100ppb<br />
and brominated<br />
TID Nitro functional groups (TNT etc.) 1ppb, 50ppb<br />
ECD Electronegative compounds 10ppb<br />
RGD Reducing gases (such as H2 and CO) 10ppb<br />
FPD Sulfur and phosphorus 200ppb and 10ppb<br />
FPD/FID Sulfur, phosphorus, and<br />
hydrocarbons<br />
200ppb, 10ppb, and<br />
100ppm<br />
Dual FPD Sulfur and phosphorus<br />
simultaneously<br />
200ppb and 10ppb<br />
FID Dual FPD<br />
Hydrocarbons, sulfur, phosphorus<br />
simultaneously<br />
100ppm, 200ppb,<br />
and 10ppb<br />
Heated Split/Splitless Injector<br />
Permits the use of narrow-bore capillary columns (0.32mm i.d.<br />
and smaller) in either split or splitless modes. Allows 0.53mm<br />
capillary columns and 1/8" packed columns to be used in<br />
split, splitless or on-column modes. Injector temperature is<br />
adjustable or programmable to 300°C.<br />
Heated Split/Splitless Injector<br />
Description<br />
Part No.<br />
Heated Split/Splitless Injector 8690034<br />
Heated Split/Splitless Injector with PTV 8611303<br />
Heated Flash Vaporization Injector<br />
Vaporizes the sample prior to the column. Ideal for desorption<br />
of SPME fibers or injection of extremely dirty samples. The<br />
injector heater block can be heated to 300°C.<br />
Heated Flash Vaporization Injector<br />
Description<br />
Part No.<br />
Heated Flash Vaporization Injector 8690025<br />
SRI <strong>GC</strong> Detectors (choose up to four per chassis)<br />
Description<br />
Part No.<br />
CCD (Catalytic Combustion Detector) 86902007<br />
TCD (Thermal Conductivity) 8690107<br />
FID (Flame Ionization) 8690010<br />
DELCD (Dry Electrolytic Conductivity) 86901026<br />
FID/DELCD Simultaneous 8692026<br />
HID (Helium Ionization Detector) 8690030<br />
PID (Photo-Ionization) 8690040<br />
NPD (Nitrogen-Phosphorus) 8690015<br />
NPD/DELCD (Series Detector) 8611299<br />
TID (Thermionic Ionization Detector) 8690017<br />
ECD (Electron Capture) 8690020<br />
RGD (Reduction Gas Detector) 8611293<br />
FPD (Flame Photometric) 8690080<br />
FPD/FID Simultaneous 8691080<br />
DFPD (Dual Flame Photometric) 8690085<br />
related products<br />
Need septa<br />
See pages 289–292.<br />
204 www.discoverysciences.com