gas chromatography<br />

Heliflex ® USP 467<br />

Capillary Kits<br />

premium<br />

• Tested for organic volatile impurities<br />

• Kits for Method I and V for Method 467<br />

• Guard columns plus connector<br />

USP Method 467 deals with the determination of organic<br />

volatile impurities in pharmaceuticals, which results from<br />

solvents commonly used in the manufacturing process.<br />

Method I Kit Contains:<br />

AT-5, (USP G27) 30m x 0.53mm x 5.00μm; 5 x Universal<br />

FSOT Connectors; and 5 x 5m Deactivated Guard Columns<br />

(0.53mm i.d.).<br />

Method V Kit Contains:<br />

AT-624, (USP G43) 30m x 0.53mm x 3.00μm; 5 x Universal<br />

FSOT Connectors; and 5 x 5m Deactivated Guard Columns<br />

(0.53mm i.d.).<br />

Method I Kit Specifications<br />

Phase:<br />

(5% Phenyl)-95% Methylpolysiloxane<br />

Polarity: Non-Polar<br />

Temp. Limit: -60–350°C<br />

USP Code: G27<br />

Ideal For: Drug Analysis<br />

3<br />

5<br />

USP 467 - Trace Volatiles<br />

8<br />

1797<br />

1. Ethylene Oxide<br />

2. Impurity<br />

3. Methylene Chloride<br />

4. Chloroform<br />

5. Benzene<br />

6. Trichloroethylene<br />

7. 1,4-Dioxane<br />

8. Dimethyl Sulfoxide<br />

Method V Kit Specifications<br />

Phase:<br />

(6% Cyanopropylphenyl)-94% Methylpolysiloxane<br />

Polarity: Intermediate<br />

Temp. Limit: 20–260°C<br />

USP Code: G43<br />

Ideal For: Drug Analysis<br />

USP 467 - Method V<br />

1866<br />

4<br />

1. Ethylene Oxide<br />

2. Methylene Chloride<br />

2<br />

3. Chloroform<br />

4. Benzene<br />

5. Trichloroethylene<br />

6. 1,4-Dioxane<br />

5 6<br />

gc columns | capillary<br />

7<br />

1<br />

12<br />

4<br />

6<br />

3<br />

0 3 6 9 12 15 18 Min.<br />

Column: Heliflex ® AT-5, 30m x 0.53mm x 5.00μm<br />

(Part No. 16859)<br />

Temp: 35°C (5 min hold) to 175°C at 8°C/min<br />

Carrier Gas: Helium at 35cm/sec<br />

Detector: FID at 260°C<br />

0 4 8 12 16 20 Min.<br />

Column: Heliflex ® AT-624, 30m x 0.53mm x 3.00μm<br />

(Part No. 16889)<br />

Temp: 40°C<br />

Carrier Gas: Helium at 35cm/sec<br />

Detector: FID<br />

more info<br />

For more information on Pharmaceutical analysis,<br />

request brochure #470.<br />

USP 467 Capillary Kits<br />

Description<br />

Part No.<br />

Capillary Kits<br />

USP 467/Method I Capillary Kit 13963<br />

USP 467/Method V Capillary Kit 13971<br />

Replacement Components<br />

AT-5, 30m x 0.53mm x 5.0μm 16859<br />

AT-624, 30m x 0.53mm x 3.0μm 16889<br />

Universal FSOT Connectors, 5/pk 20400<br />

Deactivated Guard Columns, 5m x 0.53mm, 5/pk 13990<br />

www.discoverysciences.com<br />

229