gas chromatography<br />
gc instruments<br />
Preconfigured SRI <strong>GC</strong>s<br />
BTU Gas Analyzer—8610C Chassis<br />
For the analysis of natural gas and computing the BTU rating.<br />
Measures nitrogen, methane, carbon dioxide, ethane, water,<br />
propane, iso and normal butanes, iso and normal pentanes,<br />
and C6 plus hydrocarbons.<br />
• Thermal conductivity detector<br />
• 10-port gas sampling valve<br />
• Packed <strong>GC</strong> column<br />
• 30 meter capillary column<br />
BTU Gas Analyzer<br />
Description<br />
110V<br />
Part No.<br />
220V<br />
Part No.<br />
BTU Gas Analyzer 86103070 8610518<br />
Environmental <strong>GC</strong>—8610C Chassis<br />
Ideal for laboratory or field-testing applications where space,<br />
price, and versatility are crucial. The Environmental <strong>GC</strong> is<br />
designed for EPA methods 5030, 5030/5035. It will easily<br />
generate certification quality data for EPA Methods 8021,<br />
8010, 8015, TO-14, and many others.<br />
• FID, PID, and DELCD detectors<br />
• Equipped with the method 5030/5035 compliant purge<br />
and trap<br />
• Built-in air compressor<br />
• 60 meter capillary column<br />
• Four-channel PeakSimple data system<br />
Environmental <strong>GC</strong><br />
Description<br />
110V<br />
Part No.<br />
220V<br />
Part No.<br />
Environmental <strong>GC</strong> 8610058 8612258<br />
PCB <strong>GC</strong>—8610C Chassis<br />
Detects PCBs in soil and other solids. Also used for analysis<br />
of pesticides, PAHs, JP-4, kerosene, and diesel. Accepts<br />
1-gram samples.<br />
• FID/DELCD combination detector<br />
• Built-in thermal desorber<br />
• Built-in air compressor<br />
• Four-channel PeakSimple data system<br />
PCB <strong>GC</strong><br />
Description<br />
110V<br />
Part No.<br />
220V<br />
Part No.<br />
PCB <strong>GC</strong> 8611265 8611308<br />
BTEX <strong>GC</strong>—8610C Chassis with FID/PID<br />
Designed for the analysis of benzene, toluene, ethylbenzene,<br />
and xylenes.<br />
• Method 5030/5035 compliant purge and trap<br />
• Built-in air compressor<br />
• 60 meter capillary column<br />
• Four-channel PeakSimple data system<br />
BTEX <strong>GC</strong><br />
110V<br />
Part No.<br />
220V<br />
Part No.<br />
Description<br />
BTEX <strong>GC</strong> 8612250 8610510<br />
5030/5035 Compliant Upgrade 8611267 8611309<br />
TO-14 <strong>GC</strong>—8610C Chassis<br />
Designed for the TO-14 or an ambient air analysis.<br />
• PID and FID/DELCD detectors<br />
• Dual trap sample concentrator<br />
• Built-in air compressor<br />
• Vacuum pump interface<br />
• 60 meter capillary column<br />
• Four-channel PeakSimple data system<br />
TO-14 <strong>GC</strong><br />
Description<br />
110V<br />
Part No.<br />
220V<br />
Part No.<br />
TO-14 <strong>GC</strong> 8610502 8610515<br />
Mud-Logging <strong>GC</strong>—8610C Chassis<br />
Reports the total hydrocarbons of a gas stream as well as<br />
performing separations.<br />
• Flame ionization and catalytic combustion detector<br />
• Packed <strong>GC</strong> column<br />
• Built-in air compressor<br />
• 10-port gas sampling valve<br />
• Four-channel PeakSimple data system<br />
Mud-Logging <strong>GC</strong><br />
Description<br />
110V<br />
Part No.<br />
220V<br />
Part No.<br />
Mud-Logging <strong>GC</strong> 8610500 8610511<br />
TOGA <strong>GC</strong> System—8610C Chassis<br />
This portable unit determines the gases dissolved in<br />
transformer oil.<br />
• HID and/or TCD detectors<br />
• MoleSieve and silica gel-packed columns<br />
• Syringe pump for industry standard 50mL syringes<br />
• Dual 10-port gas sampling valves<br />
• Gas extraction loop<br />
TOGA <strong>GC</strong> System<br />
110V<br />
Part No.<br />
220V<br />
Part No.<br />
Description<br />
TOGA with TCD Detector 8611326 8611327<br />
TOGA with HID Detector 8611328 8611329<br />
TOGA with TCD and HID Detector 8611330 8611331<br />