gas chromatography<br />
Alltech ® <strong>GC</strong> Packed Columns<br />
Custom Deactiglas ® Glass<br />
• Silane treated for inertness<br />
• Precision bore glass for reproducibility<br />
• Brass fittings and vespel/graphite ferrules included<br />
• Available packed or empty<br />
Key to Configurations for Glass Columns<br />
A1 (Arm 1)<br />
S (Span)<br />
A2 (Arm 2)<br />
A1 (Arm 1)<br />
gc columns | packed<br />
Alltech ® Deactiglas ® <strong>GC</strong> Columns are fabricated from<br />
precision-bore (2mm ±0.05mm or 4mm ±0.1mm i.d.) glass.<br />
All columns are 1/4" o.d. unless otherwise specified. Columns<br />
longer than 2 meters may have joints. Several additional<br />
services such as stainless steel fittings and preconditioning<br />
of the packing are available. Certain expensive stationary<br />
phases and packings may require a surcharge.<br />
Due to space limitations we are not able to list all of the<br />
different manufacturers columns in our catalog. However,<br />
they are still available and can be specified at time of order<br />
placement. If you do not see your instrument on the following<br />
pages, please call Customer Service.<br />
Special Services for Glass Columns<br />
Description<br />
Part No.<br />
Stainless Steel Fittings (Per Column)<br />
C-14010N<br />
Preconditioned Packing (Per Column) C-14005<br />
5290<br />
A1 (Arm 1)<br />
A2 (Arm 2)<br />
A2 (Arm 2)<br />
S (Span)<br />
S (Span)<br />
Deactiglas ® Column Ordering Instructions:<br />
1. Choose column configuration part no. below.<br />
2. Choose either a pretested packing (p247–248) or create a custom<br />
packing (refer to p249–250) by specifying information below:<br />
Stationary Phase A<br />
% Loading<br />
Stationary Phase B<br />
% Loading<br />
Stationary Phase C<br />
% Loading<br />
0043<br />
Deactiglas ® Glass <strong>GC</strong> Columns<br />
Chromatograph Configuration Length i.d.<br />
Agilent 5830, 5840, 5985<br />
2513<br />
Packed<br />
Part No.<br />
Empty<br />
Part No.<br />
On-Column Injection<br />
A1 = 10.72" (272mm) 3ft 2mm 131122 131121<br />
A2 = 7.18" (182mm) 6ft 2mm C6067 6067<br />
S = 6" (152mm) 6ft 4mm C6076 6076<br />
4691<br />
Not On-Column Injection<br />
A1 = 8.95" (227mm) 3ft 2mm C6564 6564<br />
A2 = 9.25" (235mm) 6ft 2mm C6568 6568<br />
S = 6" (152mm) 6ft 4mm C6572 6572<br />
On-Column Injection<br />
A1 = 10.72" (272mm) 6ft 2mm C6055 6055<br />
A2 = 7.18" (182mm) 6ft 4mm C6061 6061<br />
S = 9" (229mm)<br />
2514<br />
Not On-Column Injection<br />
A1 = 8.95" (227mm) 6ft 2mm C6578 6578<br />
A2 = 9.25" (235mm) 6ft 4mm C6580 6580<br />
S = 9" (229mm)<br />
4695<br />