gas chromatography<br />

Alltech ® <strong>GC</strong> Packed Columns<br />

Custom Deactiglas ® Glass<br />

• Silane treated for inertness<br />

• Precision bore glass for reproducibility<br />

• Brass fittings and vespel/graphite ferrules included<br />

• Available packed or empty<br />

Key to Configurations for Glass Columns<br />

A1 (Arm 1)<br />

S (Span)<br />

A2 (Arm 2)<br />

A1 (Arm 1)<br />

gc columns | packed<br />

Alltech ® Deactiglas ® <strong>GC</strong> Columns are fabricated from<br />

precision-bore (2mm ±0.05mm or 4mm ±0.1mm i.d.) glass.<br />

All columns are 1/4" o.d. unless otherwise specified. Columns<br />

longer than 2 meters may have joints. Several additional<br />

services such as stainless steel fittings and preconditioning<br />

of the packing are available. Certain expensive stationary<br />

phases and packings may require a surcharge.<br />

Due to space limitations we are not able to list all of the<br />

different manufacturers columns in our catalog. However,<br />

they are still available and can be specified at time of order<br />

placement. If you do not see your instrument on the following<br />

pages, please call Customer Service.<br />

Special Services for Glass Columns<br />

Description<br />

Part No.<br />

Stainless Steel Fittings (Per Column)<br />

C-14010N<br />

Preconditioned Packing (Per Column) C-14005<br />

5290<br />

A1 (Arm 1)<br />

A2 (Arm 2)<br />

A2 (Arm 2)<br />

S (Span)<br />

S (Span)<br />

Deactiglas ® Column Ordering Instructions:<br />

1. Choose column configuration part no. below.<br />

2. Choose either a pretested packing (p247–248) or create a custom<br />

packing (refer to p249–250) by specifying information below:<br />

Stationary Phase A<br />

% Loading<br />

Stationary Phase B<br />

% Loading<br />

Stationary Phase C<br />

% Loading<br />

0043<br />

Deactiglas ® Glass <strong>GC</strong> Columns<br />

Chromatograph Configuration Length i.d.<br />

Agilent 5830, 5840, 5985<br />

2513<br />

Packed<br />

Part No.<br />

Empty<br />

Part No.<br />

On-Column Injection<br />

A1 = 10.72" (272mm) 3ft 2mm 131122 131121<br />

A2 = 7.18" (182mm) 6ft 2mm C6067 6067<br />

S = 6" (152mm) 6ft 4mm C6076 6076<br />

4691<br />

Not On-Column Injection<br />

A1 = 8.95" (227mm) 3ft 2mm C6564 6564<br />

A2 = 9.25" (235mm) 6ft 2mm C6568 6568<br />

S = 6" (152mm) 6ft 4mm C6572 6572<br />

On-Column Injection<br />

A1 = 10.72" (272mm) 6ft 2mm C6055 6055<br />

A2 = 7.18" (182mm) 6ft 4mm C6061 6061<br />

S = 9" (229mm)<br />

2514<br />

Not On-Column Injection<br />

A1 = 8.95" (227mm) 6ft 2mm C6578 6578<br />

A2 = 9.25" (235mm) 6ft 4mm C6580 6580<br />

S = 9" (229mm)<br />

4695<br />

240 www.discoverysciences.com