Narrow Multi-Deck Produce/Dairy/Deli Merchandiser<br />

ON6UM - 8’ & 12’<br />

Electrical Data<br />

Standard Fans<br />

High Efficiency<br />

Fans<br />

Anti-Condensate 1<br />

Heaters<br />

Defrost Heaters<br />

Fans<br />

per<br />

120 Volts 120 Volts 120 Volts 208 Volts 240 Volts<br />

Model<br />

Case Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts<br />

ON6UM 8’ 3 1.50 90 0.70 42 0.25 30 3.85 800 4.44 1065<br />

12’ 4 2.00 120 0.93 56 0.38 46 5.77 1200 6.67 1600<br />

Lighting Data<br />

Clearvoyant LED Lighting<br />

Fluorescent<br />

(Per Light Row)<br />

Lighting<br />

(Per Light Row)<br />

Standard Power<br />

(Cornice)<br />

High Power<br />

(Cornice)<br />

Lights<br />

per Light<br />

120 Volts 120 Volts 120 Volts<br />

Model Row Length Amps Watts Amps Watts Amps Watts<br />

ON6UM 8’ 2 4’ 0.47 56 0.20 23.8 0.44 52.4<br />

12’ 3 4’ 0.70 84 0.30 35.7 0.66 78.6<br />

Guidelines & Control Settings<br />

Model<br />

3 BTUH/ft<br />

Superheat<br />

Set Point @Bulb<br />

(oF)<br />

Evaporator<br />

(oF)<br />

Discharge<br />

Air<br />

(oF)<br />

Return<br />

Air<br />

(oF)<br />

Discharge 4<br />

Air Velocity<br />

(FPM)<br />

ON6UM 2 960 6-8 22 28 40 300<br />

Defrost Controls<br />

Model<br />

Defrosts<br />

per Day<br />

Run-Off<br />

Time (min)<br />

Electric Defrost Timed-Off Defrost Hot Gas Defrost Reverse Air Defrost<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (oF)<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (oF)<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (oF)<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (oF)<br />

ON6UM 4 6-8 35 48 --- 7 --- 26 45 --- ---<br />

1 Anti-condensate heater data for unlighted rear sill. For lighted rear sill, double the values.<br />

2 Model ON6UM only available for meat application with a thermopane-glass front or a curved plexiglass front.<br />

3 BTUH/ft notes:<br />

- Listed BTUH/ft indicate parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.11.<br />

- Listed case BTUH/ft indicates unlighted shelves. For T8 lighted shelves and 3rd row lighting, add 80 BTUH per 4’ lighted shelf and 60 BTUH per 3’ lighted shelf to determine Total<br />

Lighting BTUH Load, then divide the Total Lighting BTUH Load by the length of the case. For LED lighting, add 36 BTUH per 4’ lighted shelf and 27 BTUH per 3’ lighted shelf to<br />

determine Total Lighting BTUH Load, then divide the Total Lighting BTUH Load by the length of the case.<br />

- Standard fans increase refrigeration load by 96 BTUH/fan.<br />

4 Average discharge air velocity at peak of defrost.<br />

Medium Temperature Defrost Schedule<br />

Defrost per Day Time<br />

1 12 midnight<br />

2 12am - 12pm<br />

3 6am - 2pm - 10pm<br />

4 12am - 6am - 12pm - 6pm<br />

All measurements are taken per ARI 1200 - 2002 specifications.<br />