Multi-Deck Self-Contained Produce/Dairy/Deli Merchandiser<br />

O5DMA - 4’, 6’ & 8’<br />

System Requirements<br />

Model Volts Phase Hz Wire<br />

Minimum<br />

Circuit<br />

Ampacity<br />

Maximum<br />

Overcurrent<br />

Protection<br />

O5DMA 4' 208 1 60 2 wire + ground 22.10 35<br />

6' 208 1 60 2 wire + ground 23.03 40<br />

8' 208 1 60 2 wire + ground 23.93 45<br />

Electrical Data<br />

Standard<br />

Fans<br />

Drain<br />

Pump<br />

Evaporator<br />

Pan Heater<br />

Maximum<br />

Lights<br />

Fans<br />

per<br />

120 Volts 120 Volts 120 Volts 120 Volts<br />

Model Case Amps Watts Amps Watts Amps Watts Amps Watts<br />

O5DMA 4' 2 1.00 60 1.10 66 7.21 1500 3.18 382<br />

6' 2 1.00 60 1.10 66 7.21 1500 4.59 551<br />

8' 3 1.50 90 1.10 66 7.21 1500 4.59 551<br />

Guidelines & Control Settings<br />

Model<br />

24hr Energy<br />

Usage<br />

(kWh)<br />

Suction Pressure<br />

@ Case Outlet<br />

(psig)<br />

Superheat<br />

Set Point @ Bulb<br />

(Fo)<br />

Discharge<br />

Air<br />

(Fo)<br />

Return<br />

Air<br />

(Fo)<br />

Discharge 1<br />

Air Velocity<br />

(FPM)<br />

O5DMA 52 6-8 30 44 250<br />

52 6-8 30 44 250<br />

52 6-8 30 44 250<br />

Condensing Unit Data<br />

Model Volts Phase<br />

Frequency<br />

(Hz) HP<br />

RLA 2<br />

(amps)<br />

LRA 3<br />

(amps) Refrig.<br />

Lbs. of<br />

Refrig.<br />

O5DMA 208 1 60 1 9.6 46 R404A 4.5<br />

208 1 60 1-3/4 10.9 56 R404A<br />

208 1 60 2-1/4 12.4 61 R404A 9.7<br />

Defrost Controls<br />

Model<br />

Defrosts<br />

Per Day<br />

Electric Defrost Timed Off Defrost Hot Gas Defrost Reverse Air Defrost<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (°F)<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (°F)<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (°F)<br />

Fail-Safe<br />

(min)<br />

Termination<br />

Temp (°F)<br />

O5DMA 4 - - - 4 - - - 42 47 - - - - - - - - - - - -<br />

1 Average discharge air velocity at peak of defrost.<br />

2 RLA = Running Load Amps<br />

3 LRA = Locked Rotor Amps<br />

4 NOTE: “- - -” not an option on this case model.<br />

Medium Temperature Defrost Schedule<br />

Defrost per Day Time<br />

1 12 midnight<br />

2 12am - 12pm<br />

3 6am - 2pm - 10pm<br />

4 12am - 6am - 12pm - 6pm<br />

All measurements are taken per ARI 1200 - 2002 specifications.<br />