07.01.2015 Views

Engineering Reference Manual 2010 - Hillphoenix

Engineering Reference Manual 2010 - Hillphoenix

Engineering Reference Manual 2010 - Hillphoenix

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

International Style Self-Contained Mobile Dual Temp. Merchandiser<br />

OSIOZA-4’<br />

System Requirements<br />

Plug Cord<br />

Model Volts Phase Hz Style Length<br />

OSIOZA 120 1 60 NEMA 5-20 10 ft<br />

Guidelines & Control Settings<br />

Model<br />

24hr Energy<br />

Usage<br />

(kWh)<br />

Suction Pressure<br />

@ Case Outlet<br />

(psig)<br />

Superheat<br />

Set Point @ Bulb<br />

(Fo)<br />

Discharge<br />

Air<br />

(Fo)<br />

Return<br />

Air<br />

(Fo)<br />

Discharge 1<br />

Air Velocity<br />

(FPM)<br />

OSIOZA 25.0 12-14 3-4 -24 -10 220<br />

Condensing Unit Data<br />

Frequency<br />

RLA 2<br />

LRA 3<br />

Lbs. of<br />

Model Volts Phase (Hz) HP (amps) (amps) Refrig. Refrig.<br />

OSIOZA 120 1 60 3/4 10.9 85.5 R404A 3.75<br />

Defrost Controls<br />

Electric Defrost Timed Off Defrost Hot Gas Defrost Reverse Air Defrost<br />

Defrosts Fail-Safe Termination Fail-Safe Termination Fail-Safe Termination Fail-Safe Termination<br />

Model Per Day (min) Temp (°F) (min) Temp (°F) (min) Temp (°F) (min) Temp (°F)<br />

OSIOA-P 2 45 45 - - - 4 - - - - - - - - - - - - - - -<br />

1 Average discharge air velocity at peak of defrost.<br />

2 RLA = Running Load Amps<br />

3 LRA = Locked Rotor Amps<br />

4 NOTE: “- - -” not an option on this case model.<br />

Medium Temperature Defrost Schedule<br />

Defrost per Day Time<br />

1 12 midnight<br />

2 12am - 12pm<br />

3 6am - 2pm - 10pm<br />

4 12am - 6am - 12pm - 6pm<br />

All measurements are taken per ARI 1200 - 2002 specifications.<br />

346 05/10