ON6UM<br />

(5” BASEFRAME)<br />

EXTENDED STANDARD FRONT<br />

12" INTERNATIONAL DELI<br />

STYLE FRONT<br />

3" INTERNATIONAL DELI<br />

STYLE FRONT<br />

10"<br />

LOAD LIMIT<br />

LINE<br />

72 5/8 in<br />

[184.5 cm]<br />

10"<br />

12"<br />

14"<br />

51 3/8 in<br />

[130.5 cm]<br />

STANDARD<br />

FRONT<br />

19 15/16 in<br />

[50.7 cm]<br />

4" SOLID FRONT<br />

24 1/8 in<br />

[61.4 cm]<br />

8 15/16 in<br />

[22.6 cm]<br />

26 1/16 in<br />

[66.1 cm]<br />

6" THERMOPANE FRONT<br />

8 15/16 in<br />

[22.6 cm]<br />

18 15/16 in<br />

[48.1 cm]<br />

6" PLEXIGLAS FRONT<br />

16"<br />

24 15/16 in<br />

[63.3 cm]<br />

COIL<br />

PLENUM<br />

17 in<br />

[43.2 cm]<br />

21 3/16 in<br />

[53.8 cm]<br />

17 in<br />

[43.2 cm]<br />

25 7/16 in<br />

[64.6 cm]<br />

17 in<br />

[43.2 cm]<br />

27 5/16 in<br />

[69.3 cm]<br />

17 in<br />

[43.2 cm]<br />

27 1/8 in<br />

[68.9 cm]<br />

5 1/8 in [13.1 cm]<br />

4 in [10. cm]*<br />

24 3/16 in [61.4 cm]<br />

29 3/8 in [74.7 cm]<br />

35 13/16 in [91.0 cm]<br />

REAR REFRIGERATION<br />

(12 1/4" off of floor)<br />

35 13/16 in<br />

[91.0 cm]<br />

24 3/16 in<br />

[61.4 cm]<br />

8 9/16 in<br />

[21.8 cm]<br />

26 3/16 in<br />

[66.5 cm]<br />

**<br />

4 in<br />

[10.2 cm]<br />

23 1/4 in<br />

[59.1 cm]<br />

29 3/8 in<br />

[74.7 cm]<br />

WIRING-TO-TRAY<br />

(STANDARD)<br />

(Connection must be<br />

flexible to front of case)<br />

1 1/2" PVC DRAIN<br />

CONNECTION<br />

C<br />

FRONT<br />

L<br />

OF CASE<br />

96 in [243.8 cm] {8' case}<br />

144 in [365.8 cm] {12' case}<br />

KICK PLATE<br />

LOCATION<br />

REFRIGERATION<br />

1 1/2 in [3.8 cm]<br />

{END}<br />

8 11/16 in [22.1 cm]<br />

NOTES:<br />

* STUB-UP AREA<br />

** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS<br />

• FRONT AND REAR SILL HEIGHTS VARY WITH BASEFRAME HEIGHT<br />

• ENDS ADD APPROXIMATELY 1 INCH TO CASE HEIGHT<br />

• A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND A WALL<br />

• AVAILABLE SHELF SIZES: 10", 12", 14" & 16"<br />

• DASHED LINES SIGNIFY AREA INSIDE BASE RAIL BEHIND KICK-PLATE<br />

COMPONENT<br />

92 05/10