increasing the void volume <strong>of</strong> the substrate without involving into the biochemical<br />

process <strong>of</strong> composting due to its inert properties.<br />

4.2.1. Pretreatment and preparation <strong>of</strong> the composting raw material<br />

Green waste was being shredded using a shredding device in order to minimize the<br />

size <strong>of</strong> waste and to increase the porosity <strong>of</strong> the substrate and to ease the agitation <strong>of</strong><br />

the composting raw material. All the materials used as feedstock to supply the<br />

bioreactor were weighted, according to the composting recipe <strong>of</strong> each composting<br />

trial, and packed in order to be ready to be fed into the bioreactor.<br />

4.2.2. Feeding the in-vessel bioreactor<br />

The feeding <strong>of</strong> the bioreactor was performed via the conveyor belt on which the<br />

feedstock was loaded manually using shovels.<br />

4.3. Composting process control<br />

Composting process control involves all the actions that had been planned and carried<br />

out with respect to the operational conditions <strong>of</strong> the in-vessel bioreactor.<br />

4.3.1. Programming the plc <strong>of</strong> the in-vessel bioreactor<br />

The operation <strong>of</strong> the agitation, hydration and aeration systems is being performed by<br />

the PLC (Programming Logic Controller) automatic control system. These operations<br />

can also be performed manually. The specifications <strong>of</strong> each operation are given<br />

below:<br />

Programming the frequency and duration <strong>of</strong> the substrate’s agitation<br />

The electric monitor can operate X times per day for a duration <strong>of</strong> Y minutes per<br />

hour. The maximum set values are Χmax = 12 times/day and Ymax = 15 minutes<br />

while the minimum ones are Χmin = 0 times/day and Ymin = 0 minutes.<br />

Programming the frequency and duration <strong>of</strong> the substrate’s aeration<br />

24