FWS 1206<br />

Fail-To-Safe Standstill Monitors<br />

Features<br />

• <strong>Co</strong>nfirmation of standstill using 1 or 2<br />

impulse sensors<br />

• Uses additional standstill signal, e.g. PLC<br />

as second input channel<br />

• PL d per EN ISO 13849-1, <strong>Co</strong>ntrol Category<br />

3 to EN 954-1<br />

• Operational voltage 24 VDC<br />

• Reset input<br />

• 2 short-circuit proof semiconductor outputs<br />

• Integral System Diagnostics (ISD)<br />

• 2 channel microprocessor control<br />

• Customer-specific standstill frequencies<br />

possible<br />

• 2 enabling paths<br />

Dimensions<br />

22.5 x 75 x 110 mm<br />

ISD<br />

The following faults are recognized by the safety<br />

controller and indicated by means of ISD<br />

• Interruption of the connections to one of the<br />

inductive proximity switches<br />

• Failure of the proximity switches<br />

• Failure of one channel being evaluated<br />

• Failure of the unit’s internal safety relay to pull-in or<br />

drop-out<br />

• Faults on input or relay control circuits of the safety<br />

controller<br />

Model<br />

Designation<br />

FWS 1206A-24VDC (Execution A)<br />

FWS 1206C-24VDC (Execution C)<br />

Standstill<br />

Frequencies<br />

Execution A<br />

Execution C<br />

Function<br />

Table<br />

Additional<br />

transistor output Y<br />

Function of<br />

output Y<br />

Input X1 1Hz 1Hz<br />

Input X2 2Hz 1Hz<br />

Y1<br />

Y2<br />

Enable, Enabling<br />

circuits closed<br />

Fault, high signal<br />

Approvals BG UL CSA<br />