FWS 2106<br />

Typical<br />

Applications<br />

10<br />

Typical<br />

Wiring<br />

Diagram<br />

Application<br />

Notes<br />

• The solenoid interlock can be<br />

opened when the FWS 2106 has<br />

registered standstill of the motor by<br />

means of the two PNP inductive<br />

prox imity switches and the additional<br />

standstill signal H7. The coil of the<br />

solenoid interlock is then energized<br />

by operation of the pushbutton E<br />

• The AES guard door controller<br />

checks the position of the guard<br />

device.<br />

• Monitoring of the guard device<br />

using a solenoid interlock.<br />

• To achieve PL d or control category 3<br />

the exclusion of faults due to<br />

“Breakage or release of the actuator,<br />

fault in the solenoid interlock” is to be<br />

substan tiated and documented.<br />

• Release is only possible when the<br />

run-down movement has come to<br />

an end.<br />

• When 1 sensor is used, the<br />

standstill frequencies must be<br />

identical and inputs X2 and X4<br />

must be bridged.<br />

• The wiring diagram is with the<br />

guard device closed and<br />

shows the de-energized<br />

condition.<br />

381