11.01.2015 Views

FLAMMABLE GAS DETECTOR - Omni Instruments

FLAMMABLE GAS DETECTOR - Omni Instruments

FLAMMABLE GAS DETECTOR - Omni Instruments

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>FLAMMABLE</strong> <strong>GAS</strong><br />

<strong>DETECTOR</strong><br />

CAPTEX<br />

Flame proof sensor<br />

Quick response time<br />

Low cost<br />

www.omniinstruments.co.uk<br />

Your environment, your safety,<br />

let’s manage them together


CELLULECF 939 CERTIFIE EExd IC T6<br />

SENSORCF 939 APPROVEDEExd IIC T6<br />

T amb : -20°C 70°C<br />

INERIS 94. Y 9001 U<br />

62 033 ARRAS CEDEX<br />

Made in France<br />

Let’s secure your activities together<br />

Reliable and safe operation<br />

The flammable gas detector CAPTEX is designed to<br />

preserve small and middle premises from any<br />

explosion risk. It meets your quality and commercial<br />

requirements.<br />

The sensor of the CAPTEX is flame proof and the<br />

detector can be placed in hazardous areas. It is<br />

connected to an OLDHAM gas monitor.<br />

Manufacturer :<br />

Function :<br />

Range :<br />

Casing :<br />

Ingress protection :<br />

Sensor :<br />

Type of sensor :<br />

Cable entry :<br />

Wiring Connection :<br />

Output :<br />

Power consumption<br />

and loop impedance :<br />

Approval :<br />

• OLDHAM SA<br />

• Flammable gas detector<br />

TECHNICAL CHARACTERISTICS<br />

• 0-100% LIE of the measured gas<br />

• PVC<br />

• IP55<br />

• Aluminium<br />

• Catalytic<br />

• PVC gland<br />

• 3 active wires<br />

• Bridge<br />

Connection<br />

• Refer to the gas monitor<br />

• EEx IId CT6 (for the sensor)<br />

INERIS 94 Y 9001U<br />

UK / Europe Office<br />

Tel: +44 (0)8700 434040<br />

Fax: +44 (0)8700 434045<br />

info@omniinstruments.co.uk<br />

www.omniinstruments.co.uk<br />

OLDHAM gas monitor<br />

The basic component of a detector is its sensor, based<br />

on the catalytic oxidation principle and with a flame<br />

proof construction, it consists of pellistors in a<br />

wheatstone bridge.<br />

The detecting filaments, when heated and exposed to<br />

gas, unbalance the weatstone bridge and cause a<br />

voltage variation proportional to the concentration of<br />

gas. This signal is transmitted to the control unit. The<br />

compensating filament prevents the effects of humidity<br />

variations or temperature variations.<br />

C A PT E X<br />

CAPTEX<br />

Conformity : • CEM<br />

Dimensions : • 105 x 89 x 50 mm<br />

Operating<br />

temperature : • -15 °C to +55 °C<br />

Operating humidity : • 0-95 % RH<br />

Pressure : • Atm +/-10%<br />

T(90) :<br />

• 15s<br />

Precision : • 3%<br />

Life span :<br />

• › 4 years<br />

guarantee :<br />

• 1 year<br />

105<br />

Australia / Asia Pacific Office<br />

Tel +61 (0)282 442 363<br />

Fax +61 (0)294 751 278<br />

info@omniinstruments.com.au<br />

www.omniinstruments.com.au<br />

89<br />

C A P T E X<br />

CELLULECF939 CERTIFIEEEExd IIC T6<br />

SENSORCF939 APPROVEDEExd IIC T6<br />

T amb : -20°C 70°C<br />

INERIS 94. Y 9001 U<br />

62 033 ARRAS CEDEX<br />

Made in France<br />

50<br />

USA / Canada Office<br />

Tel +1-866-849-3441<br />

Fax +1-866-628-8055<br />

info@omniinstruments.net<br />

www.omniinstruments.net<br />

▲<br />

OLDHAM<br />

This is not a contractually binding document. OLDHAM SA reserves the right to make any changes, without notice, to the technical characteristics of its equipement. Designed and created by Audace 33 3 21 135 600. Edition ref.: CAPTEXGB02