--++----++++Ex appoval - 5335A:KEMA 03ATEX1508 X.................................. II 3 GD Ex nA [nL] IIC T6...T4 or. . II 3 GD Ex nL IIC T6...T4 or. . II 3 GD Ex nA [ic] IIC T6...T4 or. . II 3 GD Ex ic IIC T6...T4ATEX Installation Drawing No............... 5335QA02ConnectionsInput:RTD, 2-wire RTD, 3-wire RTD, 4-wire TC, internal CJC3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6Ex / I.S. approval - 5335D:KEMA 03ATEX1537..................................... II 1 G Ex ia IIC T4 or T6. . II 1 D Ex iaDMax. amb. temperature for T1...T4.............. 85°CMax. amb. temperature for T5 and T6 ....... 60°CATEX, applicable in zone............................. 0, 1, 2, 20, 21 or 22ATEX Installation Drawing No............... 5335QE01TC, external CJC3 4 5 6mV3 4 5 6- +Resistance, 2-wire Resistance, 3-wire3 4 5 6 3 4 5 6FM, applicable in......................................... IS, Class I, Div. 1, Group A, B, C, DIS, Class I, Zone 0, AEx ia IICFM Installation Drawing No.................. 5300Q502-+-+CSA, applicable in....................................... IS, Class I, Div. 1, Group A, B, C, D,Ex ia IICIS, Class I, Zone 0, AEx ia IICCSA Installation Drawing No................ 533XQC03RTD, differenceResistance, 4-wire or average3 4 5 6 3 4 5 6TC, differenceor average,with internal CJC3 4 5 6TC, differenceor average,with external CJC3 4 5 6INMETRO 09/UL-BRCO-0002..................... BR-Ex ia IIC T4 or T6 or-40°C ≤ T amb. ≤ +85°C, or-40°C ≤ T amb. ≤ +60°C212121Marine approval:Det Norske Veritas, Ships & Offshore.......... Standard for Certification No. 2.4GOST R approval:VNIIM & VNIIFTRI, Cert. no.......................... See www.prelectronics.comObserved authority requirements: Standard:EMC 2004/108/EC....................................... EN 61326-1ATEX 94/9/EC.............................................. EN 60079-0, EN 60079-11,EN 60079-15 and EN 60079-26.EN 61241-0 and EN 61241-11FM................................................................ 3600, 3611, 3610CSA, CAN / CSA.......................................... C22.2 No. 157, E60079-11, UL 913INMETRO..................................................... IEC 60079-0 and IEC 60079-11mV, differenceor average3 4 5 621Output:2-wire installation1 2+m A -22 23


Serial no:Tag no:Input range:Connection:PRetop 5331Pt100 DIN/IEC0.00 - 50.00 C Sensor e ror: Upscale3-wire--1.00 secSupply +8.0...35 VDC1Supply -2m A4...20 mAProgrammingPRetop 5335 can be configured in the following 3 ways:1. With PR electronics A/S’ communications interface Loop Link and PReset PCconfiguration software.2. With a <strong>HART</strong> ® modem and PReset PC configuration software.3. With a <strong>HART</strong> ® communicator with PR electronics A/S’ DDL driver.4 m AD / A0 . . . 1 6m A1: Loop LinkFor programming please refer to the drawing below and the help functions inPReset..Loop Link is not approved for communication with modules installed inhazardous (Ex) areas.C P UE E P R O M12BlackRedDisconnect* Yellow* GreenReceivingEquipment+VsupplyInputPRetop 5335ConnectorFile Product Input Output Communication Language Option 08:30:00Date: 2004-8-10043201594PRelectronicsAnalog input Analog outputInput type: Output type: 4 - 20mACold junction comp:Response time:LoopLink5909 - USB5905 - RS232* Connected only foron-line programmingmV RTD, lin. R- wire4 3 2+m V65Int.CJC5 3 3 543--A / DPGAM U X+TCInput gnd.Block diagramExt.CJCEx circuit, only 5335DComm.24 25


S e r i a l n o :T a g n o :I n p u t r a n g e :C o n n e c t i o n :P R e t o p 5 3 3 1P t 100 D I N / I E C0 . 0 - 50 . 0 C S e n s o r e r r o r :3 - w i r e-1 . 00 s e cU p s c a l e2: <strong>HART</strong> ® modemFor programming please refer to the drawing below and the help functions inPReset.P R e t o p 5 3 3 5<strong>HART</strong> ® modem123: <strong>HART</strong> ® communicatorFor programming please refer to the drawing below. To gain access to productspecificcommands, the <strong>HART</strong> ® communicator must be loaded with thePR electronics A/S DDL driver. This can be ordered either at the <strong>HART</strong> ®Communica.tion Foundation or at PR electronics A/S.1areaF i l e P r o d u c t I n p u t O u t p u t C o m m u n i c a t i o n L a n g u a g e O p t i o n 0 8 : 3 0 : 0 0D a t e : 1994 - 8 - 10943201594P R e l c t r o n i c sA n a l o g i n p u t A n a l o g o u t p u tI n p u t t y p e : O u t p u t t y p e : 4 - 2 0 m AC o l d j u c t i o n c o m p :R e s p o n s e t i m e :Safe areaRload > 250 Ω, < 1100 ΩReceivingEquipment+VsupplyInputReceivingEquipment+VsupplyConnection of transmitters inmultidrop modeThe <strong>HART</strong> ® communicator or a PC modem can be connected accross AB orBC.+Powersupply-The outputs of max. 15 transmitters can be connected in parallel for a digital<strong>HART</strong> ® communication on 2-wires.Before it is connected, each transmitter must be configured with a unique numberfrom 1 to 15. If 2 transmitters are configured with the same number, both willbe excluded. The transmitters must be programmed for multidrop mode (witha fixed output signal of 4 mA). Maximum current in the loop is therefore 60 mA.The communication is either by means of a <strong>HART</strong> ® communicator or a <strong>HART</strong> ®modem.The PReset PC configuration software can configure the individual transmitterfor multidrop mode and provide it with a unique polling address.Mechanical specificationsR+-ABRload > 250 Ω, < 1100 ΩCPRetop5335PRetop5335Max. 15 transmittersPRetop5335Mounting of sensor wires2InputRload > 250 Ω, < 1100 ΩP R e t o p 5 3 3 5Wires must be mounted between the metalplates.26 27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!