Soft starters DS and DM - Moeller Electric Parts
Soft starters DS and DM - Moeller Electric Parts
Soft starters DS and DM - Moeller Electric Parts
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>DS</strong>4 soft <strong>starters</strong><br />
14/30<br />
Technical Data Technical Data<br />
<strong>Soft</strong> <strong>starters</strong> <strong>Soft</strong> <strong>starters</strong><br />
<strong>DS</strong>4 <strong>Moeller</strong> HPL0211-2007/2008<br />
http://catalog.moeller.net http://catalog.moeller.net<br />
<strong>Moeller</strong> HPL0211-2007/2008<br />
<strong>DS</strong>4<br />
General<br />
St<strong>and</strong>ards IEC/EN 60947-4-2 (-M(R))<br />
IEC/EN 60947-4-3 (-M)<br />
<strong>DS</strong>4-340-2K2-M(R) <strong>DS</strong>4-340-2K2-M(R)-DC <strong>DS</strong>4-340-4K0-M(R) <strong>DS</strong>4-340-5K5-M(R) <strong>DS</strong>4-340-7K5-M(R) <strong>DS</strong>4-340-11K-M(R)<br />
IEC/EN 60947-4-2 (-M(R))<br />
IEC/EN 60947-4-3 (-M)<br />
Approvals UL/CSA UL/CSA UL/CSA UL/CSA UL/CSA UL/CSA<br />
Climatic proofing Damp heat, constant according to IEC 60068-2-78;<br />
damp heat, cyclical, according to IEC 60068-2-10<br />
Damp heat, constant according to IEC 60068-2-78;<br />
damp heat, cyclical, according to IEC 60068-2-10<br />
Ambient temperature °C 0 – 40 0 – 40 0 – 40 0 – 40 0 – 40 0 – 40<br />
Ambient temperature, storage °C 25…55 25…55 25…55 25…55 25…55 25…55<br />
Altitude m 0 – 1000 0 – 1000 0 – 1000 0 – 1000 0 – 1000 0 – 1000<br />
Mounting position vertical vertical vertical vertical vertical vertical<br />
Degree of protection (Power connection) IP21 IP21 IP 20 (IP 00) IP 20 (IP 00) IP 20 (IP 00) IP 20 (IP 00)<br />
Protection against direct contact Finger <strong>and</strong> back-of-h<strong>and</strong> proof Finger <strong>and</strong> back-of-h<strong>and</strong> proof<br />
Overvoltage category/pollution degree II/2 II/2 II/2 II/2 II/2 II/2<br />
Shock resistance 8 g/11 ms 8 g/11 ms 8 g/11 ms 8 g/11 ms 8 g/11 ms 8 g/11 ms<br />
Vibration resistance to EN 60721-3-2 g 2M2 2M2 2M2 2M2 2M2 2M2<br />
Power loss at rated operational current e W – – – – – –<br />
Dimensions (W H D) mm 45 149 189.5 45 149 189.5 65 149 189.5 65 149 189.5 110 149 189.5 110 149 189.5<br />
Weight kg 0.8 0.8 1.0 1.0 1.7 1.7<br />
Radio interference level „A“ „A“ „A“ „A“ „A“ „A“<br />
Main conducting paths<br />
Rated operating voltage Ue V AC 110…500 110…500 110…500 110…500 110…500 110…500<br />
Supply frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60<br />
Control section power supply V AC internal via power connection internal via power connection<br />
Rated operational current<br />
AC–-51 Ie A 11 11 17 22 29 41<br />
AC-53 (inductive load) Ie A 6 6 9 12 16 23<br />
Assigned motor rating (st<strong>and</strong>ard connection)<br />
230 V kW 1.1 1.1 2.2 3 4 5.5<br />
400 V kW 2.2 2.2 4 5.5 7.5 11<br />
460 V HP 3 3 5 7 10 15<br />
500 V kW 3 3 5.5 5.5 7.5 11<br />
Overload cycle to IEC/EN 60947-4-2<br />
AC-51 (only for M types) 11A: AC-51: 1.5 – 1: 99 – 600 11A: AC-51: 1.5 – 1: 99 – 600 17A: AC-51: 1.5 – 1: 99 – 600 22A: AC-51: 1.5 – 1: 99 – 600 29A: AC-51: 1.5 – 1: 99 – 600 41A: AC-51: 1.5 – 1: 99 – 600<br />
AC-53a (without bypass) 6A: AC-53a: 6 – 0.5: 99 – 600 6A: AC-<br />
53a: 6 – 5: 99 – 20<br />
Terminal capacities<br />
Cable lengths<br />
Solid mm2 1 (1.5 – 6)<br />
2 (1.5 – 4)<br />
Flexible with ferrule mm2 1 (1.5 – 6)<br />
2 (1.5 – 2.5)<br />
Str<strong>and</strong>ed mm2 1 (1.5 – 6)<br />
2 (1.5 – 4)<br />
Solid or str<strong>and</strong>ed AWG 1 (16 – 8)<br />
2 (16 – 12)<br />
6A: AC-53a: 6 – 0.5: 99 – 600 6A: AC-<br />
53a: 6 – 5: 99 – 20<br />
1 (1.5 – 6)<br />
2 (1.5 – 4)<br />
1 (1.5 – 6)<br />
2 (1.5 – 2.5)<br />
1 (1.5 – 6)<br />
2 (1.5 – 4)<br />
1 (16 – 8)<br />
2 (16 – 12)<br />
9A: AC-53a: 6 – 0.5: 99 – 600 9A: AC-<br />
53a: 6 – 5: 99 – 20<br />
1 (1.5 – 35)<br />
2 (1.5 – 10)<br />
1 (1.5 – 25)<br />
2 (1.5 – 6)<br />
1 (1.5 – 35)<br />
2 (1.5 – 10)<br />
1 (16 – 4)<br />
2 (16 – 10)<br />
12A: AC-53a: 6 – 0.5: 99 – 600 12A:<br />
AC-53a: 6 – 5: 99 – 20<br />
1 (1.5 – 35)<br />
2 (1.5 – 10)<br />
1 (1.5 – 25)<br />
2 (1.5 – 6)<br />
1 (1.5 – 35)<br />
2 (1.5 – 10)<br />
1 (16 – 4)<br />
2 (16 – 10)<br />
16A: AC-53a: 6 – 0.5: 99 – 600 16A:<br />
AC-53a: 6 – 5: 99 – 20<br />
1 (2.5 – 50)<br />
2 (2.5 – 16)<br />
1 (2.5 – 35)<br />
2 (2.5 – 10)<br />
1 (2.5 – 50)<br />
2 (2.5 – 16)<br />
1 (14 – 2)<br />
2 (14 – 8)<br />
23A: AC-53a: 6 – 0.5: 99 – 600 23A:<br />
AC-53a: 6 – 5: 99 – 20 41A: AC-53b:3 –<br />
5:360 (-M only)<br />
2 (2.5 – 50)<br />
3 (2.5 – 16)<br />
2 (2.5 – 35)<br />
3 (2.5 – 10)<br />
2 (2.5 – 50)<br />
3 (2.5 – 16)<br />
2 (14 – 2)<br />
3 (14 – 8)<br />
Tightening torque Nm 1.7 1.7 3 3 3.5 3.5<br />
Screwdriver (PZ: Pozidriv) mm PZ2 or 1 6 mm PZ2 or 1 6 mm PZ2 or 1 6 mm PZ2 or 1 6 mm PZ2 or 1 6 mm PZ2 or 1 6 mm<br />
Control cables<br />
Notes<br />
Solid mm2 1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
Flexible with ferrule mm2 1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
Str<strong>and</strong>ed mm2 1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
Solid or str<strong>and</strong>ed AWG 1 (18 – 12)<br />
2 (18 – 16)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (18 – 12)<br />
2 (18 – 16)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (18 – 12)<br />
2 (18 – 16)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (18 – 12)<br />
2 (18 – 16)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (18 – 12)<br />
2 (18 – 16)<br />
Tightening torque Nm 0.8 0.8 0.8 0.8 0.8 0.8<br />
Screwdriver (PZ: Pozidriv) mm 0.5 3.5 0.5 3.5 0.5 3.5 0.5 3.5 0.5 3.5 0.5 3.5<br />
Rated impulse withst<strong>and</strong> voltage:<br />
•1.2 ms/50 ms (rise time/fall time of the pulse to IEC/EN 60947-2 or -3)<br />
• Applies for control circuit/power section/enclosure<br />
For <strong>Moeller</strong> <strong>Electric</strong> Sales <strong>and</strong> Support call KMparts.com (866) 595-9616<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (0.75 – 2.5)<br />
2 (0.75 – 1.5)<br />
1 (18 – 12)<br />
2 (18 – 16)<br />
14/31<br />
<strong>DS</strong>4 soft <strong>starters</strong>