<strong>DS</strong>4 soft <strong>starters</strong><br />

14/4<br />

Description<br />

<strong>Soft</strong> <strong>starters</strong><br />

<strong>DS</strong>4<br />

<strong>Soft</strong> starter for three-phase motor:<br />

• <strong>DS</strong>4-340-…-M(R)<br />

• <strong>DS</strong>4-340-…-MX(R)<br />

<strong>DS</strong>4-340-…-M(R)<br />

Two-phase-controlled soft <strong>starters</strong> rated 2.2 to 11 kW for three-phase AC motors.<br />

Devices with type suffix “R” are equipped with an additional built-in reversing<br />

function.<br />

Used as semiconductor contactor (DOL starter) the “DOL actuation” causes the<br />

motor to be switched on at the ideal point <strong>and</strong> suppresses closing transients that<br />

cause current <strong>and</strong> torque oscillations of up to 20 times the motor’s rated current.<br />

<strong>DS</strong>4-340-…-MX(R)<br />

Two-phase controlled soft starter with internal bypass for three-phase motors 7.5<br />

… 15 kW.<br />

Devices with part no. suffix “R” have an additional built-in reversing function (7.5<br />

… 15 kW). A special drive method suppresses the DC component that usually occurs<br />

in two-phase control systems. The <strong>DS</strong>4 can therefore be used to start applications<br />

which previously required three-phase soft <strong>starters</strong>. The <strong>DS</strong>4 versions MX(R) are laid<br />

out for normal duty cycle requirements.<br />

L1 L2 L3<br />

T1 T2 T3<br />

<strong>Moeller</strong> HPL0211-2007/2008<br />

<strong>DS</strong>4-340-M <strong>DS</strong>4-340-MR<br />

L1 L2 L3<br />

T1 T2 T3<br />

<strong>DS</strong>4-340-MX<br />

<strong>DS</strong>4-340-MXR<br />

Part no. overview Application examples<br />

L1 L2 L3<br />

T1 T2 T3<br />

http://catalog.moeller.net<br />

L1 L2 L3<br />

T1 T2 T3<br />

• Frequent <strong>and</strong> silent switching of motors including reversing<br />

• Application examples<br />

• Replacement of reversing contactor combinations<br />

• Pump drives: <strong>Soft</strong> starting prevents sudden pressure surges. The mechanical<br />

load on the whole plant is reduced <strong>and</strong> its service life increases.<br />

• Fan drives: <strong>Soft</strong> starting prevents drive belt slippage <strong>and</strong> premature wear. The<br />

plant’s lifespan is increased.<br />

• Conveyor belts: the belt starts smoothly <strong>and</strong> the transported goods do not fall<br />

over. The mechanical load on the whole system is reduced <strong>and</strong> its lifespan<br />

increases.<br />

Documentation<br />

You can download the documentation for the <strong>DS</strong>4 soft <strong>starters</strong> from the Internet:<br />