4.1.3 Short-circuit measurements (Figure 6 and Figure 7)<br />
With the generator output terminals short-circuited to the generator circuit common, the<br />
magnitudes of the currents (I SA and I SB ) following through each output terminal shall not<br />
exceed 24.0 mA for either binary state.<br />
| I SA | ≤ 24.0 mA<br />
| I SB | ≤ 24.0 mA<br />
STEADY STATE<br />
LOGIC INPUT<br />
(1 OR 0)<br />
G<br />
A<br />
I SA<br />
B<br />
I SB<br />
C<br />
= Measured Parameter<br />
Figure 6 - Short-circuit measurements to circuit common<br />
With the generator output terminals short-circuited to each other, the magnitude of the<br />
current (I SAB ) following through the output terminals shall not exceed 12.0 mA for either<br />
binary state.<br />
| Isab | ≤ 12.0 mA<br />
STEADY STATE<br />
LOGIC INPUT<br />
(1 OR 0)<br />
G<br />
A<br />
I SAB<br />
B<br />
C<br />
= Measured Parameter<br />
Figure 7 - Short-circuit measurements<br />
9 of 31