NT ELECTRODE GAP SPECIFICATIONS<br />
AND POSITIONING<br />
To assure consistent ignition of the burner, it is important for the electrode to be positioned properly over the top of the burner.<br />
When replacing the electrode, or should you be experiencing ignition type problems, the electrode should be positioned as<br />
outlined in the drawing.<br />
1. 1/8" spark gap between electrode and ground.<br />
2. Maintain electrode position of 3/16" over burner ports.<br />
Figure 32<br />
LOCAL FLAME SENSE<br />
PARK MODEL ELECTRODE GAP SPECIFICATIONS<br />
AND POSITIONING<br />
To assure consistent ignition of the burner, it is important for the electrode to be positioned properly over the top of the burner.<br />
W hen replacing the electrode, or should you be experiencing ignition type problems, the electrode should be positioned as<br />
outlined in the drawing.<br />
1. 1/8" spark gap between electrode and ground.<br />
2. 1/4" spark gap between ground and flame sensor.<br />
3. Maintain electrode position of 3/16" over burner ports.<br />
Figure 33<br />
REMOTE FLAME SENSE<br />
38