22.01.2015 Views

Suburban Furnace Service Manual - BR Wholesale RV & Marine

Suburban Furnace Service Manual - BR Wholesale RV & Marine

Suburban Furnace Service Manual - BR Wholesale RV & Marine

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NT ELECTRODE GAP SPECIFICATIONS<br />

AND POSITIONING<br />

To assure consistent ignition of the burner, it is important for the electrode to be positioned properly over the top of the burner.<br />

When replacing the electrode, or should you be experiencing ignition type problems, the electrode should be positioned as<br />

outlined in the drawing.<br />

1. 1/8" spark gap between electrode and ground.<br />

2. Maintain electrode position of 3/16" over burner ports.<br />

Figure 32<br />

LOCAL FLAME SENSE<br />

PARK MODEL ELECTRODE GAP SPECIFICATIONS<br />

AND POSITIONING<br />

To assure consistent ignition of the burner, it is important for the electrode to be positioned properly over the top of the burner.<br />

W hen replacing the electrode, or should you be experiencing ignition type problems, the electrode should be positioned as<br />

outlined in the drawing.<br />

1. 1/8" spark gap between electrode and ground.<br />

2. 1/4" spark gap between ground and flame sensor.<br />

3. Maintain electrode position of 3/16" over burner ports.<br />

Figure 33<br />

REMOTE FLAME SENSE<br />

38

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!