Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong><br />

A Water Based Acrylic <strong>Primer</strong><br />

for <strong>Metal</strong> Surfaces<br />

Composition: Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> is a<br />

waterbased, acrylic metal primer which provides<br />

a tough, flexible film for the protection of<br />

steel against corrosion. Tremlite <strong>Metal</strong> <strong>Primer</strong><br />

<strong>WB</strong> is asbestos free and VOC compliant.<br />

Basic Uses: Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> is<br />

designed for use on rusted surfaces as a component<br />

of the Tremlite <strong>Metal</strong> Roof Coating<br />

System. Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> is spot<br />

applied to rusted areas after surface preparation.<br />

Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> can also be<br />

applied in a full coat primer application for<br />

metal surfaces.<br />

Limitations:<br />

• Surface must be free of loose rust, coatings,<br />

dirt, oils and other contaminants which<br />

would inhibit good adhesion.<br />

• Application temperature must be 50° F and<br />

rising. Do not apply when rain is imminent.<br />

• Not recommended for immersion service in<br />

water, acids, alkalies, or solvents.<br />

• Not intended for use over Kynar or other<br />

PVDF resin coatings.<br />

Features<br />

Spot application over<br />

corrosion<br />

Excellent adhesion to<br />

most metals & generic<br />

coatings<br />

Product Advantages<br />

Benefits<br />

• Reduces labor costs<br />

• Easy to use<br />

• No concern over<br />

paint performance due<br />

to unknown existing<br />

surface<br />

Trial Area: Your <strong>Tremco</strong> Representative may<br />

suggest a trial area which will allow you to evaluate<br />

one or more <strong>Tremco</strong> systems under actual<br />

field conditions.<br />

Grade: Spray/brush/roll.<br />

Packaging: Available in 5 gallon units.<br />

Color: Gray<br />

Storage Life: One Year.<br />

EQUIPMENT<br />

Airless Spray Equipment: Use a 3/8” minimum<br />

I.D. fluid hose rated for airless operation, Graco<br />

30:1 ratio Bulldog or President pump,or equivalent,<br />

and 0.021” to 0.025” spray tip at 2,400<br />

psi minimum.<br />

APPLICATION DATA<br />

Coating performance is affected by proper<br />

product selection, application, and surface<br />

preparation. Coating integrity and service life<br />

will be reduced because of improperly prepared<br />

surfaces. Proper surface preparation ensures<br />

coating adhesion to the substrate<br />

Surface Preparation: Surface must be sound,<br />

clean, dry and free from dust, oil, chalk, and<br />

other contaminants. Prepare surface using<br />

SSPC-SP2.* Wire brush, scrape, or sand down<br />

rust and loose paint. Power wash metal surface<br />

with high pressure water blast, 2000 minimum<br />

psi. For power washing previously coated surfaces,<br />

use a biodegradable detergent to assist in<br />

cleaning, then rinse the surface with clean<br />

water. New galvanized panels must weather a<br />

minimum 6 months or be treated with phosphoric<br />

acid in order to obtain proper adhesion<br />

to the metal substrate.<br />

Rust inhibitors<br />

• Penetrates, bonds, and<br />

stops existing rust preserving<br />

metal integrity<br />

* Steel Structure Painting Council<br />

• Locks out air and mois-<br />

ture to prevent<br />

corrosion<br />

Low moisture vapor<br />

transmission rate.<br />

Roofing & Weatherproofing Peace of Mind


Application: Mix each container thoroughly<br />

prior to application. Spot apply Tremlite <strong>Metal</strong><br />

<strong>Primer</strong> <strong>WB</strong> to all rusted areas after proper surface<br />

preparation. If specified, Tremlite <strong>Metal</strong><br />

<strong>Primer</strong> <strong>WB</strong> may be applied to the metal substrate<br />

in a full coat primer application. When<br />

spray applied, take necessary precaution to<br />

avoid overspray. Allow Tremlite <strong>Metal</strong> <strong>Primer</strong><br />

<strong>WB</strong> to fully dry prior to application of surface<br />

coating.<br />

Coverage Rate: Apply in a spot application or<br />

single coat at approximately 5 m 2 /L (200<br />

ft 2 /gal.).<br />

Clean up: Clean equipment immediately with<br />

water.<br />

Precautions: Users must read container labels<br />

and Material Safety <strong>Data</strong> <strong>Sheet</strong>s for health and<br />

safety precautions prior to use.<br />

Availability and Cost: Contact your local<br />

<strong>Tremco</strong> Representative for pricing and availability.<br />

For the name and number of your representative<br />

call the Roofing Division at 416/421-<br />

3300 or 800/263-6046 or in the U.S. at<br />

216/292-5000 or 800/852-6013.<br />

Maintenance: Your local <strong>Tremco</strong> Roofing<br />

Representative can provide you with effective<br />

maintenance procedures which may vary,<br />

depending upon specific conditions. Periodic<br />

inspections, early repairs and preventive maintenance<br />

are all part of a sound roof program.<br />

Guarantee/Warranty: <strong>Tremco</strong> <strong>Inc</strong>. warrants<br />

Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> to be free of defects<br />

and to meet published physical properties<br />

when cured and tested according to ASTM and<br />

<strong>Tremco</strong> standards. Under this warranty, any<br />

Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> product that is<br />

proven to be defective when applied in accordance<br />

to our written instructions, and in applications<br />

recommended by <strong>Tremco</strong> as suitable for<br />

this product, will be replaced with like product<br />

at no charge. THIS IS BUYERS SOLE AND<br />

EXCLUSIVE REMEDY.<br />

All claims concerning product defects must be<br />

made in writing within twelve (12) months of<br />

shipment. The absence of such claims in writing<br />

during this period will constitute a waiver of<br />

all claims with respect to such product.<br />

This warranty shall be IN LIEU OF any other<br />

warranty, express or implied, including but not<br />

limited to, any implied warranty of MER-<br />

CHANTABILITY OR FITNESS FOR A PARTICULAR<br />

PURPOSE.<br />

Physical Performance Characteristics<br />

Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong><br />

Property Typical Value Test Method<br />

Density @ 77°F 1186 kg/m 3 ASTM D 1475-85<br />

(9.9 lb/gal)<br />

Asbestos content None ASTM D 276-87<br />

Volatile organic 159 g/L ASTM D 3960-89<br />

compound, mixed<br />

(less water, less<br />

exempt solvents)<br />

Nonvolatile content 46% ASTM D 1644-88<br />

Technical Services: Your local <strong>Tremco</strong><br />

Representative, working with the Technical<br />

Service Staff, can help analyze conditions and<br />

needs to develop recommendations for special<br />

applications. The services of the <strong>Tremco</strong><br />

Research Center, which has earned a unique<br />

reputation in weatherproofing technology,<br />

complement and extend the services of the<br />

<strong>Tremco</strong> Technical Service Staff.<br />

Statement of Policy and Responsibility:<br />

<strong>Tremco</strong> takes responsibility for furnishing quality<br />

materials and for providing specifications and<br />

recommendations for their proper installation.<br />

As neither <strong>Tremco</strong> itself nor its Representatives<br />

practice architecture or engineering, <strong>Tremco</strong><br />

offers no opinion on, and expressly disclaims<br />

any responsibility for the soundness of any<br />

structure on which its products may be applied.<br />

If questions arise as to the soundness of a structure<br />

or its ability to support a planned installation<br />

properly, the Owner should obtain the<br />

opinion of competent structural engineers<br />

before proceeding. <strong>Tremco</strong> accepts no liability<br />

for any structural failure or for resultant damages,<br />

and no <strong>Tremco</strong> Representative is authorized<br />

to vary this disclaimer.<br />

3735 Green Road<br />

Beachwood, OH 44122<br />

216-292-5000<br />

220 Wicksteed Ave<br />

Toronto, ONT M4H 1G7<br />

416-421-3300<br />

R00-327 8/03<br />

Printed in USA