Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong><br />
A Water Based Acrylic <strong>Primer</strong><br />
for <strong>Metal</strong> Surfaces<br />
Composition: Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> is a<br />
waterbased, acrylic metal primer which provides<br />
a tough, flexible film for the protection of<br />
steel against corrosion. Tremlite <strong>Metal</strong> <strong>Primer</strong><br />
<strong>WB</strong> is asbestos free and VOC compliant.<br />
Basic Uses: Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> is<br />
designed for use on rusted surfaces as a component<br />
of the Tremlite <strong>Metal</strong> Roof Coating<br />
System. Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> is spot<br />
applied to rusted areas after surface preparation.<br />
Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> can also be<br />
applied in a full coat primer application for<br />
metal surfaces.<br />
Limitations:<br />
• Surface must be free of loose rust, coatings,<br />
dirt, oils and other contaminants which<br />
would inhibit good adhesion.<br />
• Application temperature must be 50° F and<br />
rising. Do not apply when rain is imminent.<br />
• Not recommended for immersion service in<br />
water, acids, alkalies, or solvents.<br />
• Not intended for use over Kynar or other<br />
PVDF resin coatings.<br />
Features<br />
Spot application over<br />
corrosion<br />
Excellent adhesion to<br />
most metals & generic<br />
coatings<br />
Product Advantages<br />
Benefits<br />
• Reduces labor costs<br />
• Easy to use<br />
• No concern over<br />
paint performance due<br />
to unknown existing<br />
surface<br />
Trial Area: Your <strong>Tremco</strong> Representative may<br />
suggest a trial area which will allow you to evaluate<br />
one or more <strong>Tremco</strong> systems under actual<br />
field conditions.<br />
Grade: Spray/brush/roll.<br />
Packaging: Available in 5 gallon units.<br />
Color: Gray<br />
Storage Life: One Year.<br />
EQUIPMENT<br />
Airless Spray Equipment: Use a 3/8” minimum<br />
I.D. fluid hose rated for airless operation, Graco<br />
30:1 ratio Bulldog or President pump,or equivalent,<br />
and 0.021” to 0.025” spray tip at 2,400<br />
psi minimum.<br />
APPLICATION DATA<br />
Coating performance is affected by proper<br />
product selection, application, and surface<br />
preparation. Coating integrity and service life<br />
will be reduced because of improperly prepared<br />
surfaces. Proper surface preparation ensures<br />
coating adhesion to the substrate<br />
Surface Preparation: Surface must be sound,<br />
clean, dry and free from dust, oil, chalk, and<br />
other contaminants. Prepare surface using<br />
SSPC-SP2.* Wire brush, scrape, or sand down<br />
rust and loose paint. Power wash metal surface<br />
with high pressure water blast, 2000 minimum<br />
psi. For power washing previously coated surfaces,<br />
use a biodegradable detergent to assist in<br />
cleaning, then rinse the surface with clean<br />
water. New galvanized panels must weather a<br />
minimum 6 months or be treated with phosphoric<br />
acid in order to obtain proper adhesion<br />
to the metal substrate.<br />
Rust inhibitors<br />
• Penetrates, bonds, and<br />
stops existing rust preserving<br />
metal integrity<br />
* Steel Structure Painting Council<br />
• Locks out air and mois-<br />
ture to prevent<br />
corrosion<br />
Low moisture vapor<br />
transmission rate.<br />
Roofing & Weatherproofing Peace of Mind
Application: Mix each container thoroughly<br />
prior to application. Spot apply Tremlite <strong>Metal</strong><br />
<strong>Primer</strong> <strong>WB</strong> to all rusted areas after proper surface<br />
preparation. If specified, Tremlite <strong>Metal</strong><br />
<strong>Primer</strong> <strong>WB</strong> may be applied to the metal substrate<br />
in a full coat primer application. When<br />
spray applied, take necessary precaution to<br />
avoid overspray. Allow Tremlite <strong>Metal</strong> <strong>Primer</strong><br />
<strong>WB</strong> to fully dry prior to application of surface<br />
coating.<br />
Coverage Rate: Apply in a spot application or<br />
single coat at approximately 5 m 2 /L (200<br />
ft 2 /gal.).<br />
Clean up: Clean equipment immediately with<br />
water.<br />
Precautions: Users must read container labels<br />
and Material Safety <strong>Data</strong> <strong>Sheet</strong>s for health and<br />
safety precautions prior to use.<br />
Availability and Cost: Contact your local<br />
<strong>Tremco</strong> Representative for pricing and availability.<br />
For the name and number of your representative<br />
call the Roofing Division at 416/421-<br />
3300 or 800/263-6046 or in the U.S. at<br />
216/292-5000 or 800/852-6013.<br />
Maintenance: Your local <strong>Tremco</strong> Roofing<br />
Representative can provide you with effective<br />
maintenance procedures which may vary,<br />
depending upon specific conditions. Periodic<br />
inspections, early repairs and preventive maintenance<br />
are all part of a sound roof program.<br />
Guarantee/Warranty: <strong>Tremco</strong> <strong>Inc</strong>. warrants<br />
Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> to be free of defects<br />
and to meet published physical properties<br />
when cured and tested according to ASTM and<br />
<strong>Tremco</strong> standards. Under this warranty, any<br />
Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong> product that is<br />
proven to be defective when applied in accordance<br />
to our written instructions, and in applications<br />
recommended by <strong>Tremco</strong> as suitable for<br />
this product, will be replaced with like product<br />
at no charge. THIS IS BUYERS SOLE AND<br />
EXCLUSIVE REMEDY.<br />
All claims concerning product defects must be<br />
made in writing within twelve (12) months of<br />
shipment. The absence of such claims in writing<br />
during this period will constitute a waiver of<br />
all claims with respect to such product.<br />
This warranty shall be IN LIEU OF any other<br />
warranty, express or implied, including but not<br />
limited to, any implied warranty of MER-<br />
CHANTABILITY OR FITNESS FOR A PARTICULAR<br />
PURPOSE.<br />
Physical Performance Characteristics<br />
Tremlite <strong>Metal</strong> <strong>Primer</strong> <strong>WB</strong><br />
Property Typical Value Test Method<br />
Density @ 77°F 1186 kg/m 3 ASTM D 1475-85<br />
(9.9 lb/gal)<br />
Asbestos content None ASTM D 276-87<br />
Volatile organic 159 g/L ASTM D 3960-89<br />
compound, mixed<br />
(less water, less<br />
exempt solvents)<br />
Nonvolatile content 46% ASTM D 1644-88<br />
Technical Services: Your local <strong>Tremco</strong><br />
Representative, working with the Technical<br />
Service Staff, can help analyze conditions and<br />
needs to develop recommendations for special<br />
applications. The services of the <strong>Tremco</strong><br />
Research Center, which has earned a unique<br />
reputation in weatherproofing technology,<br />
complement and extend the services of the<br />
<strong>Tremco</strong> Technical Service Staff.<br />
Statement of Policy and Responsibility:<br />
<strong>Tremco</strong> takes responsibility for furnishing quality<br />
materials and for providing specifications and<br />
recommendations for their proper installation.<br />
As neither <strong>Tremco</strong> itself nor its Representatives<br />
practice architecture or engineering, <strong>Tremco</strong><br />
offers no opinion on, and expressly disclaims<br />
any responsibility for the soundness of any<br />
structure on which its products may be applied.<br />
If questions arise as to the soundness of a structure<br />
or its ability to support a planned installation<br />
properly, the Owner should obtain the<br />
opinion of competent structural engineers<br />
before proceeding. <strong>Tremco</strong> accepts no liability<br />
for any structural failure or for resultant damages,<br />
and no <strong>Tremco</strong> Representative is authorized<br />
to vary this disclaimer.<br />
3735 Green Road<br />
Beachwood, OH 44122<br />
216-292-5000<br />
220 Wicksteed Ave<br />
Toronto, ONT M4H 1G7<br />
416-421-3300<br />
R00-327 8/03<br />
Printed in USA