Description for technical specifications<br />
The EVP wind/rain control unit automatically and independently controls and closes the frames in case of<br />
emergency through wind and rain sensors, that is when the preset values have been exceeded. The rain sensor connected to the EVP is<br />
the low voltage RPR heated version (12V). The unit allows the connection of 230V actuators. If a higher number of actuators are<br />
necessary than the standard, the system can be implemented with more motors, by presetting the equipment with<br />
a proper powerful relay or by using one or more M5 modules. Every module is controlled by the same wind and rain sensor.<br />
An AL24 feeder, preset to receive the motor’s opening and closing pulse from the EVP, is required for the power going to the low voltage<br />
24V actuators. CE marked device complying with the following regulations: EEC 89/336, EEC 73/23 and following amendments.<br />
Technical characteristics<br />
EVP<br />
Power supply voltage<br />
230V-50Hz<br />
<strong>Max</strong> output power<br />
500 W<br />
<strong>Max</strong> absorbed current<br />
2,2 A<br />
Service type<br />
S1-continuous<br />
Preset for<br />
Wind/rain sensors, manual control and/or thermostat*<br />
Operating temperature - 5 + 50°C<br />
Dimensions (<strong>mm</strong>)<br />
113x107x45<br />
C20 that can be connected<br />
2 pcs<br />
ACK4 that can be connected<br />
6 pcs<br />
C30 that can be connected<br />
6 pcs<br />
C40 that can be connected<br />
9 pcs<br />
SL60 that can be connected<br />
6 pcs<br />
(* not compatible with the C20 actuator)