1 EC TYPE-EXAMINATION CERTIFICATE<br />
2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94/9/EC<br />
3 Certificate Number: Sira 99ATEX3199 Issue: 26<br />
4 Equipment: XL/FXL/AL/SL/RX Ranges of Terminal Boxes and Control Boxes<br />
5 Applicant: Pepperl+Fuchs GmbH<br />
6 Address: Lilienthalstrasse 200<br />
68307 Mannheim<br />
Germany<br />
7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and<br />
the documents therein referred to.<br />
8 Sira Certification Service, notified body number 0518 in accordance with Article 9 of Directive 94/9/EC<br />
of 23 March 1994, certifies that this equipment has been found to comply with the Essential Health and<br />
Safety Requirements relating to the design and construction of equipment intended for use in<br />
potentially explosive atmospheres given in Annex II to the Directive.<br />
The examination and test results are recorded in the confidential reports listed in Section 14.2.<br />
9 Compliance with the Essential Health and Safety Requirements, with the exception of those listed in<br />
the schedule to this certificate, has been assured by compliance with the following documents:<br />
EN 60079-0: 2009 EN 60079-7: 2007 EN 60079-11:2007 IEC 60079-31:2008<br />
EN 60079-0:2006<br />
10 If the sign ‘X’ is placed after the certificate number, it indicates that the equipment is subject to special<br />
conditions for safe use specified in the schedule to this certificate.<br />
11 This EC type-examination certificate relates only to the design and construction of the specified<br />
equipment. If applicable, further requirements of this Directive apply to the manufacture and supply of<br />
this equipment.<br />
12 The marking of the equipment shall include the following:<br />
II 1 G<br />
Ex ia IIC T Ga<br />
(Ta = -°C to °C)<br />
II 2 GD<br />
Ex e IIC T Gb<br />
Ex tb IIIC T°C Db IP66/67<br />
(Ta = -°C to °C)<br />
<br />
<br />
<br />
<br />
<br />
Other safety codings are applicable, ‘d’ and ‘mb’, dependent on any<br />
previously certified devices that are used in the construction of the<br />
junction box/control box, refer to condition of certification clause 17.4.<br />
T6, T5, T4 or T3 dependent on the maximum ambient temperature and<br />
specified maximum power limit, see Description of Equipment.<br />
T80°C, T95°C, T130°C or T160°C dependent on the maximum ambient<br />
temperature and specified maximum power limit, see Description of<br />
Equipment.<br />
-40°C or -50°C dependent on the type of gasket or earthing<br />
arrangement, other temperatures may be applied if previously certified<br />
components are fitted, refer to condition of certification clause 17.4..<br />
+40°C, +55°C, +85°C or +120°C, other temperatures may be applied if<br />
previously certified components are fitted, refer to condition of<br />
certification clause 17.4.<br />
Project Number 22828 D R Stubbings BA MIET<br />
C. Index 04 Certification Manager<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue 1<br />
Page 1 of 7<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com
CERTIFICATION<br />
SCHEDULE<br />
EC TYPE-EXAMINATION CERTIFICATE<br />
Sira 99ATEX3199<br />
Issue 26<br />
13 DESCRIPTION OF EQUIPMENT<br />
The XL/FXL/AL/SL/RX Ranges of Terminal Boxes and Control Boxes use an enclosure that is<br />
certified as an increased safety component under Certificate Number Sira 00ATEX3027U. These<br />
enclosures can be manufactured from either stainless steel, mild steel or aluminium sheet (the RX<br />
Terminal Boxes are only manufactured from stainless steel). Sealing between the lid/body and<br />
glandplate/body interfaces is achieved with a 5 mm one piece closed cell Neoprene or Silicone gasket.<br />
The enclosures may be used in an ambient temperature range of –40°C to +85°C when fitted with a<br />
Neoprene gasket or –50°C to +120°C when fitted with a Silicone gasket, however, there is the option<br />
to replace the main enclosure earth connection; this arrangement is limited to an ambient temperature<br />
range of -40°C to 120°C.<br />
The XL range of enclosures are provided with a hinged cover and are either designated XLM when<br />
manufactured from mild steel or XLS when manufactured from stainless steel. The larger sizes can be<br />
provided with gland plates. The use of a gasket on the lid and gland plates provides the size XL*1 to<br />
XL*10D enclosures with ingress protection ratings of IP66, IP67 and IP68. The XL*11 enclosures have<br />
an ingress protection rating of IP54 and are not be used for Terminal Boxes and Control Boxes<br />
intended for dust applications. The FXL enclosures are similar to the XL enclosures having a different<br />
sealing arrangement of the cover and the RX enclosures are also similar to the XL enclosures, although<br />
are only provided in stainless steel.<br />
The SL range of enclosures are provided with a bolt on cover and are designated either SLM when<br />
manufactured from mild steel or SLS when manufactured from stainless steel or AL when<br />
manufactured from aluminium. There is no provision for gland plates and the walls are provided with<br />
plain holes for cable entries.<br />
A variety of electrical devices are then fitted in these enclosures to form the XL/FXL/ SL/AL Ranges of<br />
Terminal Boxes and Control Boxes, these include:<br />
• Increased safety terminals selected in accordance with condition of certification clause 17.3 (the<br />
RX range of terminal boxes only uses increased safety terminals and is not fitted with any of the<br />
following items).<br />
• The ‘MFT’ type terminals manufactured by Pepperl+Fuchs and certified under PTB 07ATEX1004U.<br />
• Busbar certified to DEMKO 03 ATEX 136028 U.<br />
• Ammeter certified to Sira 02ATEX3380U.<br />
• Indicator Lamp certified to Sira 04ATEX5056U.<br />
• Contact Block certified to Sira 03ATEX1269U.<br />
• Control Components certified to PTB 97ATEX1068U.<br />
• Control Components certified to PTB 98ATEX1010U.<br />
• Temperature Transmitters certified to Baseefa08ATEX0030X.<br />
• Plugs/Sockets certified to LCIE 99 ATEX 6027 X.<br />
• Plugs/Sockets certified to LCIE 00 ATEX 6010 X.<br />
• Plugs/Sockets certified to LCIE 02 ATEX 6029 X.<br />
The dissipated power in Watts for the enclosure is to be calculated in accordance with<br />
EN 60079-7:2007, Annex E, the table below contains the maximum dissipated power ratings for each<br />
Terminal Box:<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue1<br />
Page 2 of 7<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com
CERTIFICATION<br />
SCHEDULE<br />
EC TYPE-EXAMINATION CERTIFICATE<br />
Sira 99ATEX3199<br />
Issue 26<br />
Dimensions (mm)<br />
Length x width x height<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue1<br />
Designation<br />
229 x 152 x 130 XL*1/FXL*1 15<br />
260 x 260 x 150 XL*2/FXL*2 15<br />
260 x 260 x 200 XL*2D/FXL*2D 15<br />
306 x 306 x 150 XL*3/FXL*3 21<br />
306 x 306 x 200 XL*3D/FXL*3D 21<br />
380 x 260 x 150 XL*4/FXL*4 15<br />
380 x 260 x 150 XL*4D/FXL*4D 15<br />
458 x 382 x 150 XL*5/FXL*5 29<br />
458 x 382 x 200 XL*5D/FXL*5D 29<br />
480 x 480 x 150 XL*6/FXL*6 30<br />
480 x 480 x 200 XL*6D/FXL*6D 30<br />
500 x 350 x 150 XL*7/FXL*7 21<br />
500 x 350 x 200 XL*7D/FXL*7D 21<br />
620 x 450 x 150 XL*8/FXL*8 30<br />
620 x 450 x 200 XL*8D/FXL*8D 30<br />
762 x 508 x 150 XL*9/FXL*9 41.7<br />
762 x 508 x 200 XL*9D/FXL*9D 41.7<br />
914 x 610 x 200 XL*10/FXL*10 93.4<br />
914 x 610 x 300 XL*10D/FXL*10D 93.4<br />
1177 x 777 x 210 XL*11/FXL*11 100<br />
1171 x 777 x 300 XL*11D/FXL*11D 100<br />
>1177 x >777 x >210 XL*11S/FXL*11S 100<br />
110 x 110 x 65 SL*1/AL1 9<br />
120 x 120 x 80 SL*2/AL2 9<br />
150 x 120 x 80 SL*3/AL3 9<br />
150 x 150 x 90 SL*4/AL4 11<br />
190 x 150 x 90 SL*5/AL5 11<br />
190 x 190 x 100 SL*6/AL6 13<br />
100 x 100 x 60 RX1 4<br />
150 x 100 x 60 RX2 9<br />
150 x 150 x 80 RX3 9<br />
200 x 100 x 60 RX4 9<br />
200 x 200 x 80 RX5 11<br />
200 x 200 x 120 RX6 13<br />
200 x 200 x 160 RX7 13<br />
300 x 150 x 80 RX8 11<br />
300 x 200 x 80 RX9 11<br />
300 x 200 x 120 RX10 13<br />
300 x 200 x 200 RX11 15<br />
Page 3 of 7<br />
Maximum power limit (W) (For temperature class,<br />
maximum surface temperature and applicable<br />
ambient temperature, see Table below)<br />
II 1G, II 2G & II 2GD<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com
CERTIFICATION<br />
SCHEDULE<br />
EC TYPE-EXAMINATION CERTIFICATE<br />
Sira 99ATEX3199<br />
Issue 26<br />
Dimensions (mm)<br />
Length x width x height<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue1<br />
Designation<br />
300 x 300 x 120 RX12 15<br />
300 x 300 x 160 RX13 15<br />
300 x 300 x 200 RX14 15<br />
380 x 380 x 160 RX15 21<br />
380 x 380 x 200 RX16 15<br />
400 x 150 x 80 RX17 11<br />
400 x 200 x 120 RX18 15<br />
400 x 200 x 160 RX19 15<br />
400 x 200 x 200 RX20 15<br />
400 x 300 x 160 RX21 15<br />
400 x 300 x 200 RX22 15<br />
500 x 300 x 160 RX23 21<br />
500 x 300 x 200 RX24 15<br />
500 x 400 x 160 RX25 29<br />
500 x 400 x 200 RX26 29<br />
600 x200 x120 RX27 15<br />
600 x2 00 x 160 RX28 15<br />
600 x 200 x 200 RX29 15<br />
600 x 400 x 200 RX30 21<br />
600 x 600 x200 RX31 21<br />
Page 4 of 7<br />
Maximum power limit (W) (For temperature class,<br />
maximum surface temperature and applicable<br />
ambient temperature, see Table below)<br />
II 1G, II 2G & II 2GD<br />
Temperature class for gas and maximum surface temperature for dust applicable to<br />
specific maximum ambient temperature<br />
Maximum ambient temperature Temperature class for gas Maximum surface temperature for dust<br />
+40°C T6 T80°C<br />
+55°C T5 T95°C<br />
+85°C T4 T130°C<br />
+120°C T3 T160°C<br />
Variation 1 (2 October 2009) - This variation introduced the following changes:<br />
i. The recognition of the RX Range of Terminal Boxes, these are similar to the XL Range, but are<br />
only made from stainless steel and are only fitted with terminals; the Description has been<br />
modified to include these devices.<br />
Variation 2 - This variation introduced the following changes:<br />
i. Correction of marking details for Category 1.<br />
ii. Following appropriate re-assessment to demonstrate compliance with the requirements of<br />
EN 60079-0:2009 and IEC 60079-31 the standards listed in section 9 were updated.<br />
iii. Condition of certification preventing intrinsically safe and non-intrinsically safe circuits in the<br />
same enclosure removed as this is considered under installation requirements EN 60079-14.<br />
iv. Updating of the Conditions of certification.<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com
CERTIFICATION<br />
SCHEDULE<br />
EC TYPE-EXAMINATION CERTIFICATE<br />
Sira 99ATEX3199<br />
Issue 26<br />
Variation 3 - This variation introduced the following change:<br />
i. The following applicant company name and address change:<br />
ii.<br />
iii.<br />
From:<br />
<strong>Walsall</strong> Limited.<br />
Cornwallis Road<br />
West Bromwich<br />
West Midlands<br />
B70 7DX<br />
To:<br />
Pepperl+Fuchs GmbH<br />
Lilienthalstrasse 200<br />
68307 Mannheim<br />
Germany<br />
The use of alternative label materials.<br />
The addition of a Datamatrix code on the label.<br />
Variation 4 - This variation introduced the following changes:<br />
i. The ‘MFT’ type terminals manufactured by Pepperl+Fuchs and certified under PTB 07ATEX1004U<br />
were approved to be fitted within the enclosures.<br />
14 DESCRIPTIVE DOCUMENTS<br />
14.1 Drawings<br />
Refer to Certificate Annexe.<br />
14.2 Associated Sira Reports and Certificate History<br />
Issue Date File/Report no. Comment<br />
0 15 March 2000 R51X6418A The release of the prime certificate.<br />
1 25 May 2000 53V6953 The introduction of Variation 1 later re-issued 6 June<br />
2000.<br />
2 5 June 2000 53V6913 The introduction of Variation 2.<br />
3 25 May 2000 53V6964 The introduction of Variation 3.<br />
4 29 March 2001 53V7628 The introduction of Variation 4.<br />
5 16 May 2001 53V7819 The introduction of Variation 5.<br />
6 25 February 2003 R53A9491A The introduction of Variation 6.<br />
7 11 April 2003 53V10200 The prime certificate dated 15 March 2000 was re-issued<br />
to permit it to be rationalised, this includes the<br />
incorporation of the previous Variations 1 to 6.<br />
8 9 June 2003 53V10441 The certificate dated 11 April 2003 was re-issued to allow<br />
the correction of the description of the equipment.<br />
9 18 July 2003 R53A10485B The introduction of Variation 1 subsequently re-issued<br />
11 January 2005.<br />
10 16 April 2004 R53V11775A The introduction of Variation 2.<br />
11 16 November 2004 R53V11444A The introduction of Variation 3.<br />
12 9 February 2005 R51V12833A The introduction of Variation 4.<br />
13 24 May 2005 R53A11745A The introduction of Variation 5.<br />
14 1 September 2005 R51A13790A The introduction of Variation 6.<br />
15 20 October 2005 R51A14026A The introduction of Variation 7.<br />
18 23 May 2006 R51A14262A The introduction of Variation 8.<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue1<br />
Page 5 of 7<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com
CERTIFICATION<br />
SCHEDULE<br />
EC TYPE-EXAMINATION CERTIFICATE<br />
Sira 99ATEX3199<br />
Issue 26<br />
Issue Date File/Report no. Comment<br />
19 6 September 2006 R51A15302A The introduction of Variation 9.<br />
20 11 October 2006 R51A15299A The introduction of Variation 10.<br />
21 24 November 2006 R51A15714A The introduction of Variation 11.<br />
22 9 May 2007 R51A16162A The introduction of Variation 12.<br />
23 8 June 2009 R51A16981R3BB This Issue covers the following changes:<br />
• Following appropriate re-assessment to demonstrate<br />
compliance with the requirements of the EN 60079<br />
series of standards and to review the product design:<br />
• The name of the Equipment, previously E600/E700<br />
Series Junction Boxes, was changed and new box<br />
sizes in the range were acknowledged.<br />
• The documents originally listed in section 9,<br />
EN 50014:1997 (A1 to A2), EN 50020:2002,<br />
EN 50019:2000 and EN 50281-1-1:1998 (A1), were<br />
replaced by those currently listed.<br />
• The markings in section 12 were updated<br />
accordingly.<br />
• The Description of Equipment was replaced.<br />
• All previously certified drawings were removed and<br />
a new drawing list was included.<br />
• The conditions were rationalised.<br />
• All previously issued certification was compiled as a<br />
single certificate, Issue 23, Issues 0 to 22 referenced<br />
above are only intended to reflect the history of the<br />
previous certification and have not been issued as<br />
documents in this format (Because the information in Issue<br />
23 comprehensively describes the products in their present form,<br />
for clarity, the modifications associated with the above Variations<br />
have not been detailed in this Issue, if necessary, please refer to<br />
the original documents).<br />
24 2 October 2009 R51L19705a The introduction of Variation 1.<br />
25 17 August 2010 R19705B/00<br />
R22473A/R22474A<br />
The introduction of Variation 2.<br />
The introduction of Variation 3.<br />
26 26 January 2011 R22828A/00 The introduction of Variation 4.<br />
15 SPECIAL CONDITIONS FOR SAFE USE (denoted by X after the certificate number)<br />
None<br />
16 ESSENTIAL HEALTH AND SAFETY REQUIREMENTS OF ANNEX II (EHSRs)<br />
The relevant EHSRs that are not addressed by the standards listed in this certificate have been<br />
identified and individually assessed in the reports listed in Section 14.2.<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue1<br />
Page 6 of 7<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com
CERTIFICATION<br />
SCHEDULE<br />
EC TYPE-EXAMINATION CERTIFICATE<br />
Sira 99ATEX3199<br />
Issue 26<br />
17 CONDITIONS OF CERTIFICATION<br />
17.1 The use of this certificate is subject to the Regulations Applicable to Holders of Sira Certificates.<br />
17.2 Holders of EC type-examination certificates are required to comply with the production control<br />
requirements defined in Article 8 of directive 94/9/EC.<br />
17.3 This certificate does not cover terminals that may be fitted to the enclosure. Any terminals that are<br />
fitted shall be suitably certified by a notified body and installed in accordance with their certification<br />
requirements.<br />
17.4 The products covered by this certificate incorporate previously certified devices, it is therefore the<br />
responsibility of the manufacturer to continually monitor the status of the certification associated with<br />
these devices, and the manufacturer shall inform Sira of any modifications of the devices that may<br />
impinge upon the explosion safety design of their products. In addition, when a previously certified<br />
device is fitted in a Junction Box/Control Box, the marking of the final product shall be determined<br />
taking into account the marking and any limiting special conditions for safe use associated with the<br />
previously certified device. The manufacturer shall also provide the user/installer with a copy of the<br />
EC-Type Examination Certificate that is associated with these products and the instructions supplied<br />
with the Junction Box/Control Box shall make reference to the special conditions for safe use and the<br />
electrical parameters that are defined in these certificates.<br />
17.5 When the Junction Box/Control Box is prewired, it shall be subjected to a routine electric strength test<br />
carried out as follows, no breakdown shall occur:<br />
An electrical strength test of 2U + 1000 V (where U is the supply voltage) with a minimum of<br />
1500 V ac, shall be applied between each terminal way and earth, and between adjacent terminal ways<br />
for at least 60 seconds and no more than 63 seconds as required by clause 7.1 (a) of EN 60079-7:<br />
2007.<br />
Alternatively, an electrical strength test of 1.2 x the above test voltage shall be applied as above, for at<br />
least 3 seconds and no more than 5 seconds as required by clause 7.1(b) of EN 60079-7: 2007.<br />
17.6 When a junction box is manufactured to an intermediate size that is not recognised as a standard size<br />
in the tables associated with this certification, then any given dimension shall not be larger than the<br />
respective dimension of the largest enclosure or smaller than the respective dimension of the smallest<br />
enclosure. The power rating applied to a junction box of intermediate size shall be that of the next<br />
smallest enclosure.<br />
17.7 Terminals for T5 temperature classifications shall be suitable for 120°C, terminals for T4 temperature<br />
classifications shall be suitable for 145°C, terminals for T3 temperature classifications shall be suitable<br />
for 180°C.<br />
17.8 When the optional main earth connection is used as per drawing number XL/NB/503, the first nut on<br />
the opposite side of the enclosure to the seal shall be tightened onto a clean dry surface to provide a<br />
good enclosure earth contact and an IP66/67 seal.<br />
17.9 The type XL*11, FXL*11, XL*11, FXL*11D, XL*11 and FXL*11S enclosures have been afforded an<br />
ingress protection level IP54 and therefore they shall not bear any dust markings, in addition, they<br />
shall not display a rating other than IP54.<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue1<br />
Page 7 of 7<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com
Certificate Annexe<br />
Certificate Number:<br />
Equipment:<br />
Applicant:<br />
Sira 99ATEX3199<br />
XL/FXL/AL/SL/ Ranges of Terminal Boxes<br />
and Control Boxes<br />
Pepperl+Fuchs GmbH<br />
CERTIFICATION<br />
Issues 0 to 22 - The drawings listed with these Issues were rationalised and have been superseded by those<br />
detailed in Issue 8.<br />
Issue 23<br />
Drawing No. Sheet Rev. Date Description<br />
XL/NB/521 1 of 1 0 20 Oct 08 XL/FXL/SL/AL Range Enclosure Certification Label for<br />
Increased Safety Ex e Application<br />
XL/NB/522 1 of 1 0 20 Oct 08 XL/FXL/SL/AL Range Enclosure certification Label for<br />
Intrinsically Safe Ex ia Application<br />
XL/NB/524 1 of 1 0 20 Oct 08 General Assembly of XL/FXL/AL/SLType Junction Box<br />
XL/NB/525 1 of 1 0 21 Oct 08 XL/FXL Range fitment of Earth or Neutral Busbar.<br />
Busbar certification is out of date<br />
XL/NB/527 1 of 1 0 20 Oct 08 General Assembly of XL/FXL/SL/AL Type Enclosure fitted with<br />
Meter Window and Ammeter<br />
XL/NB/528 1 of 1 0 20 Oct 08 General assembly of AL/FXL/SL/AL type enclosure fitted with<br />
Indicator Lamp<br />
XL/NB/529 1 of 1 0 20 Oct 08 General Assembly of XL/FXL/SL/AL Type Enclosure fitted with<br />
Pushbuttons(s)<br />
XL/NB/530 1 of 1 0 20 Oct 08 General Assembly of XL/FXL/SL/AL Type Enclosure fitted with<br />
position switch<br />
XL/NB/531 1 of 1 0 20 Oct 08 General Assembly of XL/FXL/SL/AL type Enclosure fitted with<br />
Control Components<br />
XL/NB/532 1 of 1 0 20 Oct 08 XL/FXL/SL/AL range Enclosures fitted with Marechal Plugs and<br />
sockets or Rosemount approved temperature transmitters<br />
XL/NB/535 1 of 1 - 20 Oct 08 XL/FXL Style Enclosure fitted with Switch for Dust only<br />
application<br />
XL/NB/536 1 of 1 0 20 Oct 08 XL/FXL/SL/AL Range Certification Label for Dust only<br />
application<br />
XL/NB/537 1 of 1 0 20 Oct 08 XL/FXL/SL/AL Range with alternative method of wall<br />
mounting<br />
XL/NB/538 1 of 1 0 20 Oct 08 SL Style Enclosure used in Break Glass Application<br />
Issue 24<br />
Drawing No. Sheets Rev. Date (Sira stamp) Description<br />
RX/NB/01 1 of 1 - 24 Aug 09 RX Enclosures<br />
RX/NB/02 1 of 1 0 24 Aug 09 XL/FXL/AL/SL Enclosure<br />
Issue 25<br />
Drawing No. Sheets Rev. Date (Sira stamp) Description<br />
260-5412 1 of 1 - 17 Aug 2010 Example certification label<br />
Issue 26<br />
Drawing No. Sheets Rev. Date (Sira stamp) Title<br />
XL/NB/539 1 of 1 - 24 Jan 11 XL/FXL/SL fitted with MFT terminals<br />
This certificate and its schedules may only be<br />
reproduced in its entirety and without change.<br />
Form 9400 Issue 1<br />
Page 1 of 1<br />
Sira Certification Service<br />
Rake Lane, Eccleston, Chester, CH4 9JN, England<br />
Tel: +44 (0) 1244 670900<br />
Fax: +44 (0) 1244 681330<br />
Email: info@siracertification.com<br />
Web: www.siracertification.com