ACCESSORIES<br />

INT<br />

On/off safety switches in ac<strong>co</strong>rdance with Standard UNE-EN 60204-1.<br />

Features:<br />

• Switch to be placed beside the fan, so<br />

that mains current can be cut without<br />

handling the fan<br />

• IP65 protection<br />

• For three-phase or two-speed fans,<br />

use 6-pole switch<br />

• For single-phase fans, use a 3-pole<br />

switch<br />

Model<br />

Current<br />

(A)<br />

(kW)<br />

Cable<br />

input<br />

(mm)<br />

INT-CA 10/3CA 20 5.5 19<br />

INT-KG 10/3CA 20 5.5 23<br />

INT-KG 20/3CA 25 7.5 29<br />

INT-KG 32/3CA 32 11 29<br />

INT-KG 41/3CA 40 15 37.5<br />

INT-KG 64/3CA 63 22 37.5<br />

INT-KG 80/3CA 80 30 37.5<br />

INT-KG 100/3CA 100 37 37.5<br />

Model<br />

Current<br />

(A)<br />

(kW)<br />

Cable<br />

input<br />

(mm)<br />

INT-CA 10/6CA 20 5.5 19<br />

INT-KG 10/6CA 20 5.5 23<br />

INT-KG 20/6CA 25 7.5 29<br />

INT-KG 32/6CA 32 11 29<br />

INT-KG 41/6CA 40 15 37.5<br />

INT-KG 64/6CA 63 22 37.5<br />

INT-KG 80/6CA 80 30 37.5<br />

INT-KG 100/6CA 100 37 37.5<br />

IAT<br />

On/off safety switches for 400ºC/2h and 200ºC/2h in ac<strong>co</strong>rdance with<br />

Standard UNE-EN 60204-1.<br />

Features:<br />

• 400ºC/2h and 200ºC/2h switches to be<br />

placed beside the fan, so that the mains<br />

current can be cut off before handling the fan.<br />

• Protection IP-65 model 400ºC/2h and IP-55<br />

model 200ºC/2h<br />

Model Current<br />

(A)<br />

IAT-400-20/3P 20<br />

IAT-400-32/3P 32<br />

IAT-400-63/3P 63<br />

IAT-400-125/3P 125<br />

IAT-400-20/6P 20<br />

IAT-400-32/6P 32<br />

Model Current<br />

(A)<br />

IAT-400-63/6P 63<br />

IAT-400-125/6P 125<br />

IAT-200/16 16<br />

IAT-200/32 32<br />

IAT-200/63 63<br />

CABLE BOX<br />

Features:<br />

• Electrical six-wire cable and ground<br />

<strong>co</strong>nnection, with length of 1.5 m and<br />

terminals at each end<br />

• Cast aluminium terminal board<br />

• Terminal Strip in ceramic material<br />

C2V<br />

Switch for two-speed motors<br />

Features:<br />

• 1-0-2 three-position switch to<br />

operate two-speed motors with<br />

Dahlander <strong>co</strong>nnection<br />

• IP67 protection<br />

Electrical cable and <strong>co</strong>nnection box kit 400ºC/2h for external <strong>co</strong>nnections<br />

to the motor in fire-fighting installations<br />

• Kit certified jointly with the CJBDT<br />

extractor series, with certification<br />

Number 0370-CPD-0580<br />

Model<br />

Current<br />

(A)<br />

(kW)<br />

Cable<br />

input<br />

(mm)<br />

C2V-CG10 A441 20 5.5 20<br />

Model Maximum power<br />

motor 3x400V (kW)<br />

CABLE BOX-1-400 5.5<br />

CABLE BOX-2-400 15.0<br />

RM<br />

Electronic speed <strong>co</strong>ntrollers<br />

Features:<br />

• Electronic speed <strong>co</strong>ntrollers especially<br />

designed for fans with single-phase<br />

motors, in ac<strong>co</strong>rdance with standard<br />

EN-60335<br />

• Models RM-1, RM-2 and RM-3, IP-54<br />

protection. Models RM-00, RM-01 and<br />

RM-02, IP-44 protection<br />

• In ac<strong>co</strong>rdance with Electromagnetic<br />

Compatibility Directives 92/31/EEC and<br />

93/68/EEC and in ac<strong>co</strong>rdance with Low<br />

Voltage Directive 73/23/EEC<br />

• On/off switch.<br />

• Minimum speed adjustment<br />

• With EMC filters in ac<strong>co</strong>rdance with<br />

standard EN-55014<br />

Model Input Protection Maximum<br />

voltage<br />

current<br />

(A)<br />

RM-00 230 V-50/60 Hz IP-44 0.5<br />

RM-01 230 V-50/60 Hz IP-44 1<br />

RM-02 230 V-50/60 Hz IP-44 2<br />

RM-1 230 V-50/60 Hz IP-54 3<br />

RM-2 230 V-50/60 Hz IP-54 5<br />

RM-3 230 V-50/60 Hz IP-54 10<br />

Model A B C<br />

RM-00 81 81 66<br />

RM-01 81 81 66<br />

RM-02 81 81 66<br />

RM-1 80 145 80<br />

RM-2 96 164 85<br />

RM-3 96 164 85<br />