ACCESSORIES<br />
INT<br />
On/off safety switches in ac<strong>co</strong>rdance with Standard UNE-EN 60204-1.<br />
Features:<br />
• Switch to be placed beside the fan, so<br />
that mains current can be cut without<br />
handling the fan<br />
• IP65 protection<br />
• For three-phase or two-speed fans,<br />
use 6-pole switch<br />
• For single-phase fans, use a 3-pole<br />
switch<br />
Model<br />
Current<br />
(A)<br />
(kW)<br />
Cable<br />
input<br />
(mm)<br />
INT-CA 10/3CA 20 5.5 19<br />
INT-KG 10/3CA 20 5.5 23<br />
INT-KG 20/3CA 25 7.5 29<br />
INT-KG 32/3CA 32 11 29<br />
INT-KG 41/3CA 40 15 37.5<br />
INT-KG 64/3CA 63 22 37.5<br />
INT-KG 80/3CA 80 30 37.5<br />
INT-KG 100/3CA 100 37 37.5<br />
Model<br />
Current<br />
(A)<br />
(kW)<br />
Cable<br />
input<br />
(mm)<br />
INT-CA 10/6CA 20 5.5 19<br />
INT-KG 10/6CA 20 5.5 23<br />
INT-KG 20/6CA 25 7.5 29<br />
INT-KG 32/6CA 32 11 29<br />
INT-KG 41/6CA 40 15 37.5<br />
INT-KG 64/6CA 63 22 37.5<br />
INT-KG 80/6CA 80 30 37.5<br />
INT-KG 100/6CA 100 37 37.5<br />
IAT<br />
On/off safety switches for 400ºC/2h and 200ºC/2h in ac<strong>co</strong>rdance with<br />
Standard UNE-EN 60204-1.<br />
Features:<br />
• 400ºC/2h and 200ºC/2h switches to be<br />
placed beside the fan, so that the mains<br />
current can be cut off before handling the fan.<br />
• Protection IP-65 model 400ºC/2h and IP-55<br />
model 200ºC/2h<br />
Model Current<br />
(A)<br />
IAT-400-20/3P 20<br />
IAT-400-32/3P 32<br />
IAT-400-63/3P 63<br />
IAT-400-125/3P 125<br />
IAT-400-20/6P 20<br />
IAT-400-32/6P 32<br />
Model Current<br />
(A)<br />
IAT-400-63/6P 63<br />
IAT-400-125/6P 125<br />
IAT-200/16 16<br />
IAT-200/32 32<br />
IAT-200/63 63<br />
CABLE BOX<br />
Features:<br />
• Electrical six-wire cable and ground<br />
<strong>co</strong>nnection, with length of 1.5 m and<br />
terminals at each end<br />
• Cast aluminium terminal board<br />
• Terminal Strip in ceramic material<br />
C2V<br />
Switch for two-speed motors<br />
Features:<br />
• 1-0-2 three-position switch to<br />
operate two-speed motors with<br />
Dahlander <strong>co</strong>nnection<br />
• IP67 protection<br />
Electrical cable and <strong>co</strong>nnection box kit 400ºC/2h for external <strong>co</strong>nnections<br />
to the motor in fire-fighting installations<br />
• Kit certified jointly with the CJBDT<br />
extractor series, with certification<br />
Number 0370-CPD-0580<br />
Model<br />
Current<br />
(A)<br />
(kW)<br />
Cable<br />
input<br />
(mm)<br />
C2V-CG10 A441 20 5.5 20<br />
Model Maximum power<br />
motor 3x400V (kW)<br />
CABLE BOX-1-400 5.5<br />
CABLE BOX-2-400 15.0<br />
RM<br />
Electronic speed <strong>co</strong>ntrollers<br />
Features:<br />
• Electronic speed <strong>co</strong>ntrollers especially<br />
designed for fans with single-phase<br />
motors, in ac<strong>co</strong>rdance with standard<br />
EN-60335<br />
• Models RM-1, RM-2 and RM-3, IP-54<br />
protection. Models RM-00, RM-01 and<br />
RM-02, IP-44 protection<br />
• In ac<strong>co</strong>rdance with Electromagnetic<br />
Compatibility Directives 92/31/EEC and<br />
93/68/EEC and in ac<strong>co</strong>rdance with Low<br />
Voltage Directive 73/23/EEC<br />
• On/off switch.<br />
• Minimum speed adjustment<br />
• With EMC filters in ac<strong>co</strong>rdance with<br />
standard EN-55014<br />
Model Input Protection Maximum<br />
voltage<br />
current<br />
(A)<br />
RM-00 230 V-50/60 Hz IP-44 0.5<br />
RM-01 230 V-50/60 Hz IP-44 1<br />
RM-02 230 V-50/60 Hz IP-44 2<br />
RM-1 230 V-50/60 Hz IP-54 3<br />
RM-2 230 V-50/60 Hz IP-54 5<br />
RM-3 230 V-50/60 Hz IP-54 10<br />
Model A B C<br />
RM-00 81 81 66<br />
RM-01 81 81 66<br />
RM-02 81 81 66<br />
RM-1 80 145 80<br />
RM-2 96 164 85<br />
RM-3 96 164 85<br />
198