04.03.2015 Views

Centrifugal Fans Brochure - Flextraction.co.uk

Centrifugal Fans Brochure - Flextraction.co.uk

Centrifugal Fans Brochure - Flextraction.co.uk

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

KIT SOBREPRESIÓN<br />

The system of pressurisation of staircases, escape routes or of<br />

<strong>co</strong>nfinement enables to <strong>co</strong>ntrol the airflow automatically and<br />

to maintain a differential pressure of 50 Pa in a single stage,<br />

ac<strong>co</strong>rding to standard UNE EN 12101-6-2006.<br />

Stairwell kit sobrepresión<br />

Differential pressure transmission set (TPDA), frequency <strong>co</strong>nverter (RFM) and outlet units<br />

(CJHCH or CJBD) , for the pressurisation of the stairwells and escape routes.<br />

Kit Sobrepresión with reserve fan<br />

Differential pressure set which in<strong>co</strong>rporates a system of automatic switching to keep the<br />

overpressure in the case of a stop by the main fan. The set <strong>co</strong>nsists of a probe of differential<br />

pressure TPDA, an automatic switching board ARM (varier, sine filter and <strong>co</strong>ntrol manoeuvre)<br />

and TWIN air outlet units.<br />

Technical characteristics<br />

STAIRWELL KIT SOBREPRESIÓN<br />

Pressure transmission unit (TPDA):<br />

• 24 Vac/Vdc supply, directly from the frequency <strong>co</strong>nverter.<br />

• Output signal 4...20 mA<br />

• Adjustment of differential pressure 0...100 Pa<br />

• Includes accessories and <strong>co</strong>nnecting tube.<br />

• Models –LED, with digital differential pressure display<br />

Frequency <strong>co</strong>nverter to change the fan speed<br />

(RFM)<br />

• Converter supply, single-phase 230V. 50 Hz<br />

• Converter output voltage, three-phase 230V. 50 Hz<br />

(RFT)<br />

• Converter supply, three-phase 400V. 50 Hz<br />

• Converter output voltage, three-phase 400V. 50 Hz<br />

Switching <strong>co</strong>ntrol panel:<br />

(ARM)<br />

• It in<strong>co</strong>rporates a frequency <strong>co</strong>nverter, sinusoidal filter, <strong>co</strong>ntrol and switching manoeuvres<br />

• Converter supply, single-phase 230V. 50 Hz<br />

KIT SOBREPRESIÓN WITH<br />

RESERVE FAN<br />

Pressurisation units:<br />

• Soundproof pressurisation units designed for impulsion of air and to pressurise stairwells or<br />

emergency exits.<br />

• Fan supply, three-phase 230V. 50 Hz, directly from the frequency <strong>co</strong>nverter<br />

• For technical and manufacturing characteristics of the fan, please see the CJHCH, CJBD<br />

and TWIN series in the general catalogue.<br />

On request:<br />

• Possibility of other designs depending on the needs in the building.<br />

Order <strong>co</strong>de<br />

KIT SOBREPRESIÓN 7.100 (LED)<br />

Kit Sobrepresión:<br />

Overpressure set for<br />

staircases<br />

Kit Sobrepresión II:<br />

Overpressure set with<br />

reserve fan<br />

Maximum Airflow<br />

Reference with LED:<br />

Digital visualisation of<br />

the pressure<br />

93