ACCESSORIES<br />

Model<br />

SI-TEMP+HUMEDAD<br />

Temperature and relative humidity sensor with display<br />

Independently <strong>co</strong>ntrols the temperature and the relative humidity of the air on the premises. Automatically<br />

activates the ventilation system when it detects a temperature or humidity greater than the pre-set value. Once the<br />

environmental temperature or humidity has descended below the pre-set point, the fan remains functioning for a<br />

pre-set period, which can be adjusted by means of the internal clock.<br />

Power<br />

Output Adjustments Height<br />

installation<br />

Working<br />

temperature<br />

SI-TEMP+HUMEDAD 24V ac 0-10V dc T = 0.5ºC and HR = 2% 1.5-2.5 m +10º +40º C<br />

SI-PRESIÓN<br />

Pressure transmission unit<br />

Controls the pressure in facilities with <strong>co</strong>nstant pressure ventilation, and transforms it into an electrical signal to<br />

regulate the ventilation system and <strong>co</strong>nstantly maintain the same pressure<br />

Model<br />

Power<br />

Output<br />

Maximum<br />

<strong>co</strong>nsumption (VA)<br />

Connectors<br />

Pressure<br />

range<br />

SI-PRESIÓN TPDA-3202 24V ac/24V dc 0-10V/4-20mA 4 6.2 mm 0-2500 Pa<br />

SI-PRESIÓN TPDA-3202 c/DISPLAY 24V ac/24V dc 0-10V/4-20mA 4 6.2 mm 0-2500 Pa<br />

SI-TIMER<br />

Timer<br />

Adjusts the operating time of the ventilation system to which it is <strong>co</strong>nnected. The ventilation system is<br />

automatically activated when the light switch goes on and <strong>co</strong>ntinues to function for a pre-set time which can be<br />

altered by means of the internal clock<br />

Model<br />

Power<br />

Output<br />

Maximum<br />

intensity (A)<br />

Adjustments<br />

Working<br />

temperature<br />

SI-TIMER 220-240V ac 220-240V dc 3.0 Timing 3min-20 min -20ºC +50ºC<br />

SI-FUENTE DE<br />

ALIMENTACIÓN<br />

Power supply 24V dc / ac<br />

Powers the intelligent 24V dc/ac sensors from an input voltage of 230V. single-phase<br />

SI-FUENTE DE<br />

ALIMENTACIÓN ac<br />

SI-FUENTE DE<br />

ALIMENTACIÓN dc<br />

Model<br />

Power<br />

Output<br />

Power<br />

(VA)<br />

SI-FUENTE DE ALIMENTACIÓN dc 230 V 24V dc 30<br />

SI-FUENTE DE ALIMENTACIÓN ac 230/400 V 24/48V ac 25<br />