Centrifugal Fans Brochure - Flextraction.co.uk
Centrifugal Fans Brochure - Flextraction.co.uk
Centrifugal Fans Brochure - Flextraction.co.uk
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ACCESSORIES<br />
Model RFM-0.5 RFM-1 RFM-2 RFM-3<br />
Motor (CV) 0.5 1 2 3<br />
(kW) 0.37 0.75 1.5 2.2<br />
Current (A) 2.5 5 8 12<br />
kVA 0.95 1.9 3 4.5<br />
Input<br />
Single-phase<br />
Voltage (V) 2 x 200 ÷ 230 V (±10%)<br />
Frequency (Hz) 50 – 60 Hz (± 5%)<br />
Output<br />
Three-phase<br />
Model RFM-0.5 RFM-1 RFM-2 RFM-3<br />
Voltage (V) 3 x 200 ÷ 230 V<br />
Frequency (Hz) 0-200 Hz 0-400 Hz 0-400 Hz 0-400 Hz<br />
RFI Filter<br />
Built in<br />
Size Width (W1) mm 68 79 156 156<br />
Height (H1) mm 128 143 143 143<br />
Depth (D1) mm 115 143 143 143<br />
Weight (Kg) 0.95 0.97 1.94 2.00<br />
Method of refrigeration Radiator Forced air Forced air Forced air<br />
1. In general, all SODECA fans with a threephase<br />
motor under normal operating <strong>co</strong>nditions<br />
are suitable for working supplied with a static<br />
frequency <strong>co</strong>nverter (in ac<strong>co</strong>rdance with IEC<br />
60034-17). Nevertheless, some motors require<br />
special measures.<br />
The maximum operating frequency or speed must<br />
never exceed that for which the fan has been<br />
designed. In applications with quadratic torques<br />
such as fans and pumps, when the speed varies<br />
the absorbed power is directly proportional to the<br />
cube of the rotating speed: Pa 2<br />
= Pa 1<br />
(n 2<br />
/ n 1<br />
) 3<br />
2. The insulation of motors <strong>co</strong>upled to fans is<br />
sufficient to work without restrictions with a<br />
frequency <strong>co</strong>nverter up to voltages of < 500 V.<br />
The use of sinusoidal filters at the <strong>co</strong>nverter<br />
output will help the motor to operate properly,<br />
reducing breakdowns and increasing the fan’s<br />
service life.<br />
It is re<strong>co</strong>mmended that, for motors of sizes > 225,<br />
they be ordered with special windings to work<br />
with a frequency <strong>co</strong>nverter.<br />
3. The length of the wires running from the<br />
<strong>co</strong>nverter to the fan have a particular influence<br />
on voltage characteristics at the motor terminals.<br />
The definition of "long wires" will depend on<br />
the nominal value and the <strong>co</strong>nverter type. The<br />
manufacturer’s technical documentation must be<br />
<strong>co</strong>nsulted.<br />
4. EEx-d flame-resistant motors must be ordered<br />
for operation using a frequency <strong>co</strong>nverter. The<br />
motor manufacturer will request information about<br />
the application via a questionnaire in order to<br />
establish the working parameters. These motors<br />
must also be fitted with PTC probes.<br />
5. EEx-e increased safety motors cannot be<br />
operated with a frequency <strong>co</strong>nverter (a joint<br />
motor-<strong>co</strong>nverter certification would be required<br />
for this).<br />
KME - 10K<br />
Features:<br />
• On/Off by button<br />
• Display by means of LED of the position of On or Off<br />
• Memory of the latest position for speed regulation<br />
External <strong>co</strong>ntrol kit for On/Off and velocity <strong>co</strong>ntrol for RFM and RFT<br />
frequency <strong>co</strong>nverters<br />
• Possibility of installation on the surface or built-in<br />
GMP<br />
Electrical starter panel and protection of fans with three-phase motor, with On/Off buttons<br />
Features:<br />
• On/Off by button<br />
• In<strong>co</strong>rporates fully-cabled <strong>co</strong>ntactor and adjustable thermal relay for protection of the motor<br />
• The Off button is used to reset the thermal relay, in case it should go off due to overload<br />
• For assembly on the surface, IP-55 protection<br />
For fan with three-phase motor 230V<br />
Model<br />
Current<br />
of regulation (A)<br />
Power motor<br />
3x230V (kW)<br />
GMP-0.2-0.33/230 1.2-1.8 0.25<br />
GMP-02-0.75/230 1.8-2.8 0.37 / 0.55<br />
GMP-02-1/230 2.8-4 0.75<br />
GMP-02-1.5/230 4-6.3 1.10<br />
GMP-02-2/230 5.6-8 1.50<br />
GMP-04-3/230 7-10 2.20<br />
GMP-04-4/230 8-12.5 3.00<br />
GMP-04-5.5/230 11-17 4.00<br />
GMP-04-7.5/230 15-23 5.50<br />
GMP-04-10/230 22-32 7.50<br />
GMP-06-12.5/230 25-40 9.20<br />
GMP-06-15/230 25-40 11.00<br />
For fan with three-phase motor 400V<br />
Model<br />
Current<br />
of regulation (A)<br />
Power motor<br />
3x400V (kW)<br />
GMP-0,2-0,33/400 0,56-0,8 0,25<br />
GMP-02-0,5/400 0,8-1,2 0,37<br />
GMP-02-0,75/400 1,2-1,8 0,55<br />
GMP-02-1,5/400 1,8-2,8 1,10<br />
GMP-02-2/400 2,8-4 1,50<br />
GMP-02-3/400 4-3 2,20<br />
GMP-02-4/400 5,6-8 3,00<br />
GMP-04-5,5/400 7-10 4,00<br />
GMP-04-7,5/400 8-12,5 5,50<br />
GMP-04-10/400 11-17 7,50<br />
GMP-06-12,5/400 15-23 9,20<br />
GMP-06-15/400 15-23 11,00<br />
GMP-06-20/400 22-32 15,00<br />
GMP-06-25/400 25-40 18,50<br />
200