ACCESSORIES<br />
AR<br />
Soft starters for three-phase motors.<br />
Features:<br />
• Especially designed to reduce the current peak caused during start-up of fans with three-phase motors.<br />
• Power Voltage 400V + - 10% 50/60Hz<br />
• Mounted in box for DIN-35 rail<br />
• Possibility of adjusting the starting torque, acceleration time and deceleration time.<br />
Model AR-2 AR-4 AR-7.5 AR-10 AR-15 AR-20 AR-30<br />
Supplied voltage<br />
400 V ±10% 50/60 Hz<br />
Motor power in kW at 400 V 1.5 3 5.5 7.5 11 15 22<br />
Minimum motor power 40% of the motor’s nominal power 20% of the motor’s nominal power<br />
External fuses (quick-action) in (A) 16 25 35 25 35/40 50 63<br />
Nominal current in (A) 3.5 6.5 12 17 25 32 45<br />
Adjustment range of start-up torque From 0 to 80%<br />
Adjustment range of start-up time From 0.5 to 12 s From 0.5 to 10 s<br />
Braking torque Level set at 70%<br />
Adjustment range of deceleration time From 0.5 to 12 s From 0.5 to 10 s<br />
Setup time<br />
200 ms<br />
Working temperature<br />
0ºC….45ºC<br />
Storage temperature<br />
-25ºC….75ºC<br />
Protection level<br />
IP20<br />
Environmental <strong>co</strong>nditions Overpressure category III. Pollution level 2<br />
Power reduced with max. temperature<br />
1% for every 1ºC increase in the maximum temperature<br />
Maximum height for mounting<br />
Up to 1000 m<br />
Power reduced with max. height 0.5% for every 100 m over 1000 m.<br />
Humidity<br />
93% maximum without <strong>co</strong>ndensation<br />
Maximum cycles per hour (3 x I nom. 10 sec) 90/h 60/h 30/h 60/h 40/h 30/h 20/h<br />
Weight in kg. 0.4 1.0<br />
Measurements Width (W) mm 45 45 52.5<br />
Height (H) mm 73 173 178<br />
Depth (D) mm 122 152 158<br />
Assembly Fixing A x B On DIN guide rail<br />
RFT RFM<br />
Features:<br />
• The RFT <strong>co</strong>nverter series are suitable to vary the<br />
speed, via voltage and frequency, of axial and<br />
centrifugal fans with 400V three-phase motors.<br />
Converter power supply: 400V three-phase.<br />
50/60 Hz.<br />
• In ac<strong>co</strong>rdance with Electromagnetic Compatibility<br />
Directives 92/31/EEC and 93/68/EEC and in<br />
ac<strong>co</strong>rdance with Low Voltage Directive 73/23/EEC<br />
Frequency <strong>co</strong>nverter for 400V three-phase motors.<br />
Features:<br />
• The RFM <strong>co</strong>nverter series are suitable to vary the<br />
speed, via voltage and frequency, of axial and<br />
centrifugal fans with 230V three-phase motors.<br />
Converter power supply: 230V single-phase.<br />
50/60 Hz.<br />
• In ac<strong>co</strong>rdance with Electromagnetic Compatibility<br />
Directives 92/31/EEC and 93/68/EEC and in<br />
ac<strong>co</strong>rdance with Low Voltage Directive 73/23/EEC<br />
Model RFT-0.5 RFT-1 RFT-2 RFT-3 RFT-5.5 RFT-7.5 RFT-10 RFT-15 RFT-20 RFT-25 RFT-30<br />
Motor (CV) 0.5 1 2 3 5.5 7.5 10 15 20 25 30<br />
(kW) 0.37 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22<br />
Current (A) 1.25 2.5 4 6 9 12 16 24 30 39 45<br />
kVA 0.95 1.9 3 4.5 6.9 9.1 12.2 19.1 23.9 31.1 35.9<br />
Input<br />
Three-phase<br />
Voltage (V) 3 x 380…480 V (-15% +10%)<br />
Frequency (Hz) 50 – 60 Hz (± 5%)<br />
Output<br />
Three-phase<br />
Voltage (V) 3 x 380…480 V<br />
Frequency (Hz) 0….400 Hz 0...120 Hz<br />
Braking torque 20% (with external resistance: 100%. 150%)<br />
Braking unit In<strong>co</strong>rporated in the equipment Optional<br />
Size Width (W1) mm 70 70 100 140 140 180 180 200 250 250 304<br />
Height (H1) mm 128 128 128 128 128 220 220 284 385 385 460<br />
Depth (D1) mm 130 130 130 155 155 170 170 182 201 201 234<br />
Weight (Kg) 0.76 0.77 1.12 1.84 1.89 3.66 3.66 6 12.5 13 20<br />
Method of refrigeration<br />
Forced air<br />