Instruction Manual SMC 186-188/TSMC 188
Instruction Manual SMC 186-188/TSMC 188
Instruction Manual SMC 186-188/TSMC 188
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Compressor data for reciprocating compressor<br />
CMO 4, CMO 24-28, TCMO 28, <strong>SMC</strong> 104-116,<br />
T<strong>SMC</strong> 108-116, <strong>SMC</strong> <strong>186</strong>-<strong>188</strong>, T<strong>SMC</strong> <strong>188</strong><br />
Operating limits<br />
SABROE prescribes operating limits within which the compressor and any additional equipment<br />
must operate. These limits for R717 and R22 are shown in the following tables, together with<br />
the main data for the compressor.<br />
0171-496-EN 02.01<br />
Compressor<br />
type<br />
Number of<br />
cylinders<br />
Bore<br />
mm<br />
Stroke<br />
mm<br />
Max/min<br />
Speed<br />
RPM<br />
Swept<br />
volume<br />
max RPM*<br />
m 3 /h<br />
Weight<br />
(max.)<br />
compr. block<br />
kg<br />
CMO 4 4 65 65 1800/900 93,2 200<br />
CMO 24 4 70 70 1800/900 116 340<br />
CMO 26 6 70 70 1800/900 175 380<br />
CMO 28 8 70 70 1800/900 233 410<br />
TCMO 28 2+6 70 70 1800/900 175 410<br />
<strong>SMC</strong> 104S 4 100 80 1500/700 226 580<br />
<strong>SMC</strong> 106S 6 100 80 1500/700 339 675<br />
<strong>SMC</strong> 108S 8 100 80 1500/700 452 740<br />
<strong>SMC</strong> 112S 12 100 80 1500/700 679 1250<br />
<strong>SMC</strong> 116S 16 100 80 1500/700 905 1350<br />
T<strong>SMC</strong> 108S 2+6 ♦ 100 80 1500/700 339 775<br />
T<strong>SMC</strong> 116S 4+12 ♦ 100 80 1500/700 679 1400<br />
<strong>SMC</strong> 104L 4 100 100 1500/700 283 580<br />
<strong>SMC</strong> 106L 6 100 100 1500/700 424 675<br />
<strong>SMC</strong> 108L 8 100 100 1500/700 565 740<br />
<strong>SMC</strong> 112L 12 100 100 1500/700 848 1250<br />
<strong>SMC</strong> 116L 16 100 100 1500/700 1131 1350<br />
T<strong>SMC</strong> 108L 2+6♦ 100 100 1500/700 424 775<br />
T<strong>SMC</strong> 116L 4+12♦ 100 100 1500/700 757 1400<br />
<strong>SMC</strong> 104E 4 100 120 1500/700 339 600<br />
<strong>SMC</strong> 106E 6 100 120 1500/700 509 700<br />
<strong>SMC</strong> 108E 8 100 120 1500/700 679 770<br />
<strong>SMC</strong> 112E 12 100 120 1500/700 1018 1300<br />
<strong>SMC</strong> 116E 16 100 120 1500/700 1357 1400<br />
T<strong>SMC</strong> 108E 2+6♦ 100 120 1500/700 509 800<br />
T<strong>SMC</strong> 116E 4+12♦ 100 120 1500/700 1018 1450<br />
<strong>SMC</strong> <strong>186</strong> 6 180 140 1000/450 1283 2560<br />
<strong>SMC</strong> <strong>188</strong> 8 180 140 1000/450 1710 2840<br />
T<strong>SMC</strong> <strong>188</strong> 8 180 140 1000/450 1283 2900<br />
✶<br />
♦<br />
The maximum speed permitted can be lower than stated here depending on operating<br />
conditions and refrigerant; please see the following diagrams.<br />
Two - stage compressors (High Stage cylinders and Low Stage cylinders)<br />
0178-900-EN 21