12 OTC 20957<br />

Open-Cycle-<strong>OTEC</strong> <strong>Plantship</strong>: Two of Five 16 <strong>MW</strong>gross Modules<br />

14 m 28 m 11 m 30 m 10 m 30 m 11 m 28 m 14 m<br />

T-G<br />

T-G<br />

WW<br />

Sump<br />

Flash Evp<br />

Module<br />

RW<br />

Sump Cond Module CW<br />

Sump<br />

Cond Module<br />

RW<br />

Sump<br />

Flash Evp<br />

Module<br />

WW<br />

Sump<br />

24 m<br />

Pipe: 10 m i.d.<br />

Pipe: 10 m i.d.<br />

Pipe: 12.3 m i.d.<br />

Pipe: 12.3 m i.d.<br />

Global Volume (L x W x H) LBP: 176 m<br />

Flash Evaporator-module: 28 m x 28 m x 16 m<br />

Draft: 16 m<br />

Surface Condenser-module: 30 m x 30 m x 16 m<br />

Heigth: 24 m<br />

LP Steam TG-module: 11 m x 21 m x 21 m<br />

Beam: 90 m<br />

WW-Sumps: 2 x 14 m diameter<br />

Displacement: 247,400 tonnes<br />

CW-Sump: 1 x 13 m diameter<br />

Electricity: 414,400 <strong>MW</strong>h/year<br />

RW-Sumps: 2 x 17 m diameter Desalinated Water: 118,400 m^3/day<br />

Pipe: 8.7 m i.d.<br />

Figure 6.- <strong>50</strong> <strong>MW</strong> Open-Cycle-<strong>OTEC</strong> <strong>Plantship</strong>: Side View. Broken lines indicate space overlap.<br />

TopView Open-Cycle-<strong>OTEC</strong> <strong>Plantship</strong>: Five x 16<strong>MW</strong>gross Modules<br />

14 m 28 m 11 m 30 m 10 m 30 m 11 m 28 m 14 m<br />

Flash Evp<br />

Module<br />

T/G Cond Module Shops Live<br />

Bridge &<br />

Operations<br />

WW<br />

Sump<br />

Space<br />

Flash Evp<br />

Module<br />

T/G Cond Module<br />

CW<br />

Sump<br />

Cond Module<br />

T/G<br />

Flash Evp<br />

Module<br />

WW<br />

Sump<br />

Space<br />

90 m<br />

Flash Evp<br />

Module<br />

T/G Cond Module Cond Module T/G<br />

Flash Evp<br />

Module<br />

Global Volume (L x W x H) LBP: 176 m<br />

Flash Evaporator-module: 28 m x 28 m x 16 m<br />

Draft: 16 m<br />

Surface Condenser-module: 30 m x 30 m x 16 m<br />

Heigth: 24 m<br />

Pressure Steam TG-module: 11 m x 21 m x 21 m<br />

Beam: 90 m<br />

WW-Sumps: 2 x 14 m diameter<br />

Displacement: 247,400 tonnes<br />

CW-Sump: 1 x 13 m diameter<br />

Electricity: 414,400 <strong>MW</strong>h/year<br />

RW-Sumps: 2 x 17 m diameter Desalinated Water: 118,400 m^3/day<br />

Figure 7.- <strong>50</strong> <strong>MW</strong> Open-Cycle-<strong>OTEC</strong> <strong>Plantship</strong>: Top View. Broken lines indicate space overlap.