what is what....<br />

Optional on board<br />

remote control Receiver<br />

Unswitched + 12V<br />

Power to RX<br />

Resettable fuse for<br />

auxiliary 12V (1Amax)<br />

ANT<br />

ANT(GND)<br />

RX +12V<br />

RX serial data<br />

RX 0V<br />

+12V<br />

Auxiliary 12V Power<br />

500 mA maximum Voltage free contacts for either<br />

- 220v ac courtesy light or<br />

- Electric lock<br />

0V<br />

N/C<br />

COM<br />

N/O<br />

M2<br />

M1<br />

16 17 18 19 20 21 22 23 24 25 26 27 28 29<br />

POWER IN<br />

30A main<br />

Fuse<br />

-<br />

+<br />

30A<br />

M2 MOSFET<br />

M2<br />

0 1 2 3<br />

Overload<br />

adjust<br />

M1<br />

0 1 2 3<br />

Overload<br />

adjust<br />

light/lock<br />

relay<br />

M1 MOSFET<br />

B<br />

T<br />

R<br />

A<br />

1 2 3 4 5 6 7 8<br />

1 8<br />

Dipswitch<br />

INPUT STATUS LEDS<br />

PCB version number<br />

Current Overload adjust<br />

0 1 2 3<br />

CLOSE<br />

RELAY<br />

20A M2<br />

Fuse<br />

M2 M2 M1 M1<br />

20A<br />

( Motors 1 and 2)<br />

0 1 2 3 0 1 2 3 0 1 2 3<br />

OPEN<br />

RELAY<br />

M2<br />

CLOSE<br />

RELAY<br />

M1<br />

connections<br />

to motors<br />

20A<br />

OPEN<br />

RELAY<br />

20A M1<br />

Fuse<br />

-<br />

Connections for<br />

extended status indication<br />

1 2 3 4 5 6 7 8 9 10 11 12 13<br />

+<br />

0V<br />

LS 2 OP<br />

LS 2 CL<br />

LS 1 OP<br />

LS 1 CL<br />

Inputs description<br />

Earth<br />

BEAM<br />

PED<br />

TRIG 2<br />

TRIG 1<br />

0V<br />

NICE-HANSA- 386B??<br />

LS 2 OP<br />

BUZZER<br />

LS 2 CL<br />

Magnetic<br />

limit switches<br />

connections<br />

LS 1 OP<br />

LS 1 CL<br />

BEAM<br />

PED<br />

TRIG 2<br />

TRIG 1<br />

LIGHTENING PROTECTION<br />

BOARD (OPTIONAL)<br />

DISABLE<br />

maximum<br />

current<br />

overload<br />

detection<br />

minimum<br />

current<br />

overload<br />

detection.<br />

FACTORY<br />

DEFAULT<br />

medium<br />

current<br />

overload<br />

detection<br />

high<br />

current<br />

overload<br />

detection<br />

EXTENDED STATUS INDICATIONS:<br />

with Gate moving:<br />

- Steady on = GATE OPEN<br />

- One pulse per second = GATE OPENING<br />

LIGHTNING PROTECTION BOARD<br />

This board provides extra lightning protection on each of the<br />

8 inputs for areas where lightning strikes are common.<br />

The board is fitted over the existing input connector.<br />

gas arrestors<br />

- Two pulses per second = GATE CLOSING<br />

with Gate closed:<br />

- Five pulses per second = safety beam interrupted<br />

- Permanently OFF = battery fully charged/ all normal<br />

- Slight flickering = battery low<br />

new connections<br />

Earth<br />

BUZZER STATUS INDICATIONS:<br />

1 BEEP = Maximum current M1<br />

3 BEEPS = Clutch Sensor M1<br />

2 BEEPS = Maximum current M2 4 BEEPS = Clutch Sensor M2<br />

P-4 X361-mami