BULB REPLACEMENT<br />

The supplied 10 watt quartz Halogen lamp is a projection quality bulb. Operating<br />

the lamp at full brightness for long periods reduces the bulb's life. Using the<br />

dimmer will extend both bulb life and battery life.<br />

If you suspect the bulb is burned out:<br />

Check if the lamp will light by connecting the AC charger/adapter and powering<br />

it. If the dimmer is set halfway and the bulb won't light it probably needs to<br />

be replaced.<br />

A Phillips screwdriver is the only tool required to replace the bulb; (replacement<br />

bulb Vector part# VEC193). The replacement procedure is as follows:<br />

1. Make sure the lamp switch is turned OFF.<br />

2. Using the Phillips screwdriver, unscrew four screws that hold the shade<br />

assembly to the base.<br />

3. Set the screws aside.<br />

4. Remove the shade and set it aside.<br />

5. Using a clean soft cloth, grasp the bulb and pull the bulb straight up and remove<br />

it. Set the bulb aside.<br />

6. Using the clean cloth, grasp the new bulb and remove it from it's packaging.<br />

Avoid touching the new bulb with bare skin.<br />

7. Note the positions of the bulb's two metal pins and the small holes on the bulb<br />

socket.<br />

8. Insert the two pins of the new bulb into the socket and make sure they are fully<br />

seated in the socket.<br />

9. Turn on the dimmer and test operation of the bulb.<br />

10. Turn off the lamp and place the shade assembly on the top of the base.<br />

11. Loosely replace the four shade retaining screws.<br />

12. Using the screwdriver, carefully tighten the screws to secure the shade<br />

(clockwise). DO NOT OVERTIGHTEN.<br />

13. Dispose of the burned out bulb in a responsible manner.<br />

CLEANING<br />

Over time, there may be dust or fingerprints on the lamp. If necessary clean the<br />

lamp with, a soft clean oil-free cloth moistened with household window cleaner.<br />

Do not use alcohol based cleaners on plastic surfaces. This will eventually cause<br />

surface clouding. If the inside of the shade becomes dirty, disassemble as you<br />

would for bulb replacement and clean with window cleaner as above.<br />

BATTERY CARE<br />

Lead-acid batteries require recharging on a regular basis to maintain a full charge<br />

and to ensure good battery life. All lead-acid batteries suffer from self-discharge<br />

over time and more rapidly when they are stored at higher temperatures. Therefore,<br />

these types of batteries need periodic charging to replace energy lost through<br />

self-discharge. When the lamp is not in use, Vector recommends that the battery is<br />

recharged at least every 60 days. All batteries must be recharged as soon as possible<br />

after each use. If a battery remains in a discharged state, battery life will be<br />

reduced.<br />