<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong><br />

®<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

1. Product Name<br />

Exposed Fastener <strong>Metal</strong> Wall Panels<br />

2. Manufacturer<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

1500 Hamilton Road<br />

Bossier City, LA 71111<br />

(800) 562-3576<br />

(318) 747-8000<br />

Fax: (318) 747-8099<br />

E-mail: marketing@mcelroymetal.com<br />

www.mcelroymetal.com<br />

3. Product Description<br />

BASIC USE<br />

<strong>McElroy</strong> <strong>Metal</strong> manufactures a wide range of<br />

exposed fastener wall panels suitable for residential,<br />

commercial and industrial applications.<br />

The panels are formed into a variety of<br />

ribbed configurations appropriate for multiple<br />

project applications. See Table 1 below.<br />

COMPOSITION & MATERIALS<br />

The standard substrate for <strong>McElroy</strong> products is<br />

aluminum-zinc alloy coated Galvalumeª steel<br />

sheet conforming to ASTM A792. Galvanized<br />

TABLE 1 <strong>WALL</strong> PANEL APPLICATIONS<br />

<strong>McElroy</strong>'s Mega-Rib (7.2 panel) installed horizontally.<br />

steel sheet substrate conforming to ASTM A653<br />

and aluminum sheet conforming to ASTM B209<br />

are also available on some products.<br />

Most panels are manufactured from 24 , 26<br />

or 29 gage steel depending on the product.<br />

TYPES<br />

<strong>McElroy</strong> <strong>Metal</strong> offers a variety of exposed fastener<br />

panels with different longitudinal ribbed<br />

profiles, as detailed below:<br />

Application 5V-Crimp Mega-Rib Mini-Rib Multi-Cor M-Cor Max-Rib Ultra<br />

Residential X - X X X X<br />

Commercial X X X X X X<br />

Agricultural X - - X X X<br />

Industrial - X - X X -<br />

Post-frame - - - - - X<br />

Soffit X - X - - -<br />

Liner X - X X X X<br />

Fascia - - X - - -<br />

Roof X X - X X X<br />

Wall X X X X X X<br />

Pre-engineered buildings - X - X X -<br />

Liner panel X X X X X X<br />

Application Multi-Rib Multi-V R-Panel U-Panel Mesa<br />

Residential X - X X X<br />

Commercial X X X X X<br />

Agricultural X - X - X<br />

Industrial X X X X -<br />

Post-frame X - - - X<br />

Soffit - - - - -<br />

Liner X X X X X<br />

Fascia - - - - -<br />

Roof X - X X X<br />

Wall X X X X X<br />

Pre-engineered buildings X X X X -<br />

Liner panel X - X X X<br />

• 5V-Crimp Panel - Incorporates a classic<br />

design that will add beauty to any residential<br />

structure<br />

• Max-Rib Panel - This panel (3/4") is well suited<br />

for commercial, agricultural and residential<br />

applications<br />

• Mega-Rib (7.2) Panel - Provides optimum<br />

strength and spanning capabilities and<br />

is equally well suited for industrial and<br />

commercial applications<br />

• Mesa Panel - Features a nearly invisible lap,<br />

presenting a monolithic appearance; it is<br />

designed for post-frame and residential<br />

applications<br />

• Mini-Rib Panel - The symmetrical design<br />

makes this an appealing profile for soffit,<br />

liner and fascia applications<br />

• Multi-Cor Corrugated Panel - Designed and<br />

engineered for greater than normal spans<br />

and load-carrying characteristics, it is equally<br />

well suited for roof or wall applications<br />

• M-Cor Corrugated Panel - Like the Multi-Cor<br />

panel, this panel is also equally well suited<br />

for roof or wall applications. However, the<br />

M-Cor panel has a more subtle rib height<br />

configuration<br />

• Multi-Rib Panel - This multi-use wall and roof<br />

panel is used primarily in pre-engineered<br />

metal building applications<br />

• Multi-V Panel - This panel is designed for<br />

fastener placement in the panel valleys,<br />

making them visually less apparent<br />

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style<br />

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.


<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong><br />

®<br />

• R-Panel - A multi-use wall and roof panel<br />

used primarily in pre-engineered metal<br />

building applications<br />

• U-Panel -This wall and roof panel is also used<br />

extensively as a liner or partition panel<br />

SIZES<br />

Panel cover widths of 36" (914 mm) are standard<br />

for most wall panel products, with the exception<br />

of 5V Crimp, Multi-Cor and M-Cor. See Table 5.<br />

COLOR, FINISHES<br />

Colors shown in Table 2 are supplied standard<br />

or optional according to panel model. Consult<br />

the manufacturer’s color chart online at<br />

www.mcelroymetal.com.<br />

Galvalumeª panels are available with the<br />

Kynar 500ª/Hylar 5000ª based fluoropon 70%<br />

polyvinylidene fluoride (PVDF) paint system,<br />

which has been shown to perform better than<br />

polyester, siliconized polyester and plastisol<br />

coatings with regard to chalking and color<br />

change. See Table 3 to compare finish options<br />

by product.<br />

ACCESSORIES<br />

<strong>McElroy</strong> offers a complete selection of components<br />

and accessories, including trim, fasteners,<br />

translucent panels, closures, tape sealants, pop<br />

rivets, door track covers and roof and soffit<br />

panels. Visit www.mcelroymetal.com or consult<br />

<strong>McElroy</strong> <strong>Metal</strong> for details.<br />

LIMITATIONS<br />

Design consideration must be given to structural<br />

support, flashing and drainage systems.<br />

Consult manufacturer’s literature for detailed<br />

information on load and span tables, construction<br />

recommendations and installation<br />

procedures.<br />

4. Technical Data<br />

APPLICABLE STANDARDS<br />

American Iron and Steel Institute (AISI) - 2004<br />

Edition of the Cold Formed Steel Design Manual<br />

ASTM International<br />

• ASTM A653/A653M Standard Specification<br />

for Steel Sheet, Zinc-Coated (Galvanized)<br />

or Zinc-Iron Alloy-Coated (Galvannealed)<br />

by the Hot-Dip Process<br />

• ASTM A792/A792M Standard Specification<br />

for Steel Sheet, 55% Aluminum-Zinc Alloy-<br />

Coated by the Hot-Dip Process<br />

• ASTM B209 Standard Specification for<br />

Aluminum and Aluminum-Alloy Sheet and Plate<br />

• ASTM D2247 Standard Practice for Testing<br />

Water Resistance of Coatings in 100%<br />

Relative Humidity<br />

• ASTM E108 Standard Test Methods for Fire<br />

Tests of Roof Coverings<br />

• ASTM E119 Standard Test Methods for Fire<br />

Tests of Building Construction and Materials<br />

• ASTM E1646 Standard Test Method for<br />

Water Penetration of Exterior <strong>Metal</strong> Roof<br />

TABLE 2 COLOR<br />

Regal White<br />

Light Stone<br />

Ash Gray<br />

Roman Blue<br />

Surrey Beige<br />

Charcoal<br />

Tudor Brown<br />

Evergreen<br />

Patrician Bronze<br />

Clay<br />

Autumn Red<br />

Ivory<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

Matte Black<br />

Patina Green<br />

Dark Bronze<br />

Brite Red<br />

Regal Blue<br />

Teal<br />

Brandywine<br />

Colonial Red<br />

Sandstone<br />

Bare Galvalume<br />

Galvalume Plus<br />

Brite White<br />

Panel Systems by Uniform Static Air Pressure<br />

Difference<br />

• ASTM E1680 Standard Test Method for Rate<br />

of Air Leakage Through Exterior <strong>Metal</strong> Roof<br />

Panel Systems<br />

• ASTM G90 Standard Practice for Performing<br />

Accelerated Outdoor Weathering of<br />

Nonmetallic Materials Using Concentrated<br />

Natural Sunlight<br />

Underwriters Laboratories, Inc. (UL)<br />

• UL 263 Standard for Fire Tests of Building<br />

Construction and Materials<br />

• UL 580 Standard for Tests for Uplift<br />

Resistance of Roof Assemblies<br />

• UL 790 Standard Test Methods for Fire Tests<br />

of Roof Coverings<br />

• UL 2218 Standard for Impact Resistance of<br />

Prepared Roof Covering Materials<br />

TABLE 3 SUBSTRATE, FINISH<br />

Panel Type 5V-Crimp Mega-Rib Mini-Rib Multi-Cor M-Cor<br />

Gage 24, 26, 29 18, 20, 22, 24, 26 24, 26, 29 24, 26, 29 24, 26, 29<br />

Standard substrate, to ASTM A792 Galvalumeª Galvalumeª Galvalumeª Galvalumeª Galvalumeª<br />

Alternate substrate, to ASTM A653 N/A Galvanized Galvanized Galvanized Galvanized<br />

Coating Kynar 500ª Kynar 500ª Kynar 500ª Kynar 500ª Kynar 500ª<br />

Siliconized polyester Siliconized polyester Siliconized polyester<br />

Bare Bare Bare Bare<br />

Panel Type Multi-Rib Multi-V R-Panel U-Panel Mesa<br />

Gage 22, 24, 26 24, 26 22, 24, 26, 26 24, 26, 29 24, 26, 29<br />

Standard substrate, to ASTM A792 Galvalumeª Galvalumeª Galvalumeª Galvalumeª Galvalumeª<br />

Alternate substrate, to ASTM B209 Galvanized Galvanized Galvanized Galvanized N/A<br />

Alternate substrate, to ASTM A653<br />

Coating Kynar 500ª, Kynar 500ª, Kynar 500ª, Kynar 500ª, Kynar 500ª®<br />

Siliconized polyester Siliconized polyester Siliconized polyester Siliconized polyester<br />

Bare<br />

Bare Bare Bare<br />

Panel Type<br />

Max-Rib Ultra<br />

Gage 24, 26, 29<br />

Standard substrate, to ASTM A792<br />

Galvalumeª<br />

Kynar 500ª<br />

Coating Kynar 500ª®<br />

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style<br />

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.


<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong><br />

®<br />

TABLE 4 MEGA-RIB, MULTI-RIB, R-PANEL TECHNICAL PROPERTIES<br />

Test<br />

Air leakage, ASTM E1680<br />

APPROVALS, LISTINGS<br />

2004 Florida State Building Code, structural,<br />

non-structural<br />

ICC-ES Evaluation Report ER-5896<br />

Miami-Dade Notice of Acceptance, (NOA) -<br />

NOA #<strong>07</strong>-1219.<strong>13</strong>, Expires 20<strong>13</strong><br />

Texas Department of Insurance Windstorm<br />

Approval<br />

Underwriters Laboratories, Inc. (UL)<br />

• Multi-Rib, R-Panel, 5V-Crimp, Mega-Rib, Max-<br />

Rib, U-Panel have been approved for use in<br />

the following Underwriters Laboratories, Inc.<br />

(UL) design numbers: P225, P227, P230, P237,<br />

P250, P259, P265, P266, P268, P508, P510, P512,<br />

P514, P516, P518, P701, P711, P712, P7<strong>13</strong>, P717,<br />

P720, P722, P723, P726, P731, P732, P734, P736,<br />

P739, P740, P801, P815, P819, P824, P825, P828<br />

Visit <strong>McElroy</strong> <strong>Metal</strong>, Inc., online at www.mcelroymetal.com<br />

to obtain technical bulletins,<br />

approvals and listings by various agencies.<br />

PHYSICAL/TECHNICAL PROPERTIES<br />

See Tables 4 and 5. Technical bulletins are<br />

available online at www.mcelroymetal.com.<br />

FIRE PERFORMANCE<br />

See Table 3. For additional fire resistive assemblies<br />

and component protection information,<br />

consult <strong>McElroy</strong> Engineering Department.<br />

5. Installation<br />

PREPARATORY WORK<br />

Deliver products in manufacturer’s original,<br />

unopened, undamaged containers with identification<br />

labels intact. Inspect for damage or<br />

moisture and notify <strong>McElroy</strong> <strong>Metal</strong>, Inc., within<br />

48 hours of discovery.<br />

A forklift or crane can be used to handle<br />

unopened bundles to 25' (8 m) in length. For<br />

forklift unloading, spread forks to maximum<br />

width and place at center line weight distribution<br />

of bundle. For crane unloading, use a<br />

spreader bar to evenly distribute the bundle’s<br />

weight. Do not use cable supports as they will<br />

damage the panels.<br />

When moving individual panels, grasp<br />

panel edges and carry lengthwise, parallel to<br />

the ground. Protect the finish from scratching<br />

or abrasion.<br />

Store bundled material dry and above<br />

ground. Do not use plastic tarp, but protect<br />

from weather conditions by other means. Allow<br />

for proper air circulation to prevent moisture<br />

buildup under the tarp. Elevate one end of the<br />

bundles to allow for moisture runoff. If panels<br />

Static Pressure Air Infiltration Air Infiltration<br />

Specimen Differential Rate Rate<br />

Mega-Rib, 26 gage - 6.24 psf (- 297 Pa) - 6.24 cfm/lf 0.011 cfm/sf<br />

Mega-Rib, 26 gage + 6.24 psf (+ 297 Pa) + 6.24 cfm/lf 0.0<strong>07</strong> cfm/sf<br />

Mega-Rib, 26 gage ± 1.57 psf (± 75.2 Pa) ± 1.57 cfm/lf 0.004 cfm/sf<br />

Multi-Rib, 26 gage - 6.24 psf (- 297 Pa) 0.0<strong>07</strong> cfm/lf 0.002 cfm/sf<br />

Multi-Rib, 26 gage + 6.24 psf (+ 297 Pa) 0.004 cfm/lf 0.001 cfm/sf<br />

Multi-Rib, 26 gage - 1.57 psf (- 75.2 Pa) 0.004 cfm/lf 0.001 cfm/sf<br />

Multi-Rib, 26 gage + 1.57 psf (+ 75.2 Pa) 0.000 cfm/lf 0.000 cfm/sf<br />

R-Panel, 26 gage - 6.24 psf (- 297 Pa) 0.011 cfm/lf 0.004 cfm/sf<br />

R-Panel, 26 gage + 6.24 psf (+ 297 Pa) 0.0<strong>07</strong> cfm/lf 0.002 cfm/sf<br />

R-Panel, 26 gage - 1.57 psf (- 75.2 Pa) 0.0<strong>07</strong> cfm/lf 0.002 cfm/sf<br />

R-Panel, 26 gage + 1.57 psf (+ 75.2 Pa) 0.001 cfm/lf 0.001 cfm/sf<br />

Test Susceptibility to Leakage, FM 4471<br />

Specimen Rate Test Duration Result<br />

Mega-Rib, 24 gage Water Spray Leakage 5 gal/sf/hr 15 minutes Passed<br />

Water Depth<br />

Static Water Leakage 6" (152 mm) 7 days Passed<br />

Test<br />

Water Penetration, ASTM E1646<br />

Static Pressure Test Water<br />

Specimen Differential Rate Duration Infiltration<br />

Mega-Rib, 26 gage 12.0 psf (575 Pa) 5 gal/sf/hr 15 minutes None<br />

Multi-Rib, 26 gage 12.0 psf (575 Pa) 5 gal/sf/hr 15 minutes None<br />

R-Panel, 26 gage 12.0 psf (575 Pa) 5 gal/sf/hr 15 minutes None<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

become wet, remove all panels from bundles<br />

and dry each individually.<br />

Prolonged panel storage is not recommended.<br />

If conditions do not permit immediate<br />

installation, take extra care to protect<br />

sheets from developing rust or watermarks.<br />

Verify that site conditions are acceptable<br />

for installation. Do not proceed with installation<br />

until unacceptable conditions are corrected.<br />

Handle and store product according<br />

to <strong>McElroy</strong> <strong>Metal</strong>, Inc., recommendations.<br />

METHODS<br />

Install panels plumb, true and in correct alignment<br />

with structural framing in accordance<br />

with shop drawings and manufacturer’s<br />

instructions. Install panels in vertical installations<br />

using manufacturer’s noncorroding fasteners<br />

color matched to panel. Sight-exposed<br />

noncorroding fasteners color matched to trim<br />

are permitted. Replace products having<br />

other than minor finish damage.<br />

PRECAUTIONS<br />

Before ordering materials, have proposed<br />

installation reviewed by technical services<br />

staff. Protect installed products from damage<br />

by subsequent construction activities.<br />

Field cutting panels and driving of fasteners<br />

will create metal shavings. These must be<br />

removed from the panel surface. Failure to do<br />

so will cause rust stains on the panel surface<br />

and will void the warranty.<br />

BUILDING CODES<br />

Installation must comply with the requirements<br />

of all applicable local, state and national code<br />

jurisdictions. Current data on building code<br />

requirements and product compliance may<br />

be obtained from <strong>McElroy</strong> technical support<br />

specialists.<br />

6. Availability & Cost<br />

AVAILABILITY<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc., has 10 manufacturing<br />

facilities and 20 service centers located<br />

throughout the United States to serve the<br />

construction market. Contact <strong>McElroy</strong> <strong>Metal</strong>,<br />

Inc., for more information.<br />

COST<br />

Project-specific cost information may be<br />

obtained from a local <strong>McElroy</strong> distributor or<br />

directly from <strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

7. Warranty<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc., makes available limited<br />

warranties. For specific information regarding<br />

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style<br />

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.


<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong><br />

®<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

TABLE 5 COMPOSITION & MATERIALS, PHYSICAL PROPERTIES<br />

Panel Type 5V-Crimp Mega-Rib Mini-Rib Multi-Cor M-Cor<br />

Uplift resistance, UL 580 Class 90 Class 90 - - -<br />

Impact resistance, UL 2218 Class 4 Class 4 - Class 4 Class 4<br />

Fire resistance, UL 790 (ASTM E108 and NFPA 256) Class A Class A - Class A Class A<br />

Gage 26, 29 26, 24, 22 24, 26, 29 24, 26, 29 24, 26, 29<br />

Panel width 24" (610 mm) 36" (914 mm) 36" (914 mm) 32" (8<strong>13</strong> mm) 37.38" (949 mm)<br />

Rib depth 7/16" (11 mm) 1 1/2" (38 mm) 3/8" (9.5 mm) 7/8" (22.2 mm) 1/2" (12.7 mm)<br />

Rib spacing 12" (305 mm) 7.2" (183 mm) 3" (76 mm) 2.67" (68 mm) 2.67" (68 mm)<br />

Warranty Limited Limited Limited Limited Limited<br />

Approvals<br />

ICC-ES Evaluation Report ER-5896, minimum gage - 24 - - -<br />

UL Construction #244, minimum gage - 26 - - -<br />

2004 Florida State Building Code, structural, minimum gage - 26 - - -<br />

2004 Florida State Building Code, nonstructural, minimum gage 26 26 - - -<br />

Miami-Dade Notice of Acceptance,<br />

(NOA) #<strong>07</strong>-1219.<strong>13</strong>, Expires 20<strong>13</strong>, minimum gage 26 - - - -<br />

Texas Department of Insurance<br />

Windstorm Approval, minimum gage 29 - - - -<br />

Panel Type Multi-Rib Multi-V R-Panel U-Panel Mesa<br />

Uplift resistance, UL 580 Class 90 - Class 90 - -<br />

Impact resistance, UL 2218 Class 4 - Class 4 Class 4 -<br />

Fire resistance, UL 790 (ASTM E108 and NFPA 256) - - Class A Class A -<br />

Gage 24, 26 24, 26 24, 26, 26 PB 24, 26, 29 24, 26, 29<br />

Panel width 36" (914 mm) 35.5" (902 mm) 36" (914 mm) 36" (914 mm) 36" (914 mm)<br />

Rib depth 1 3/16" (30 mm) 1 3/16” (30 mm) 1 1/4" (32 mm) 47/64" (19 mm) 3/4" (19.1 mm)<br />

Rib spacing 12" (305 mm) 12" (305 mm) 12" (305 mm) 6" (152 mm) 9" (229 mm)<br />

Warranty Limited Limited Limited Limited Limited<br />

Approvals<br />

ICC-ES Evaluation Report ER-5896, minimum gage - - - - -<br />

UL Construction #244, minimum gage - - - - -<br />

2004 Florida State Building Code, structural, minimum gage 26 - 26 26 -<br />

2004 Florida State Building Code, nonstructural, minimum gage 26 - 26 - -<br />

Miami-Dade Notice of Acceptance,<br />

(NOA) #<strong>07</strong>-1219.<strong>13</strong>, Expires 20<strong>13</strong>, minimum gage - - - - -<br />

Texas Department of Insurance -<br />

Windstorm Approval, minimum gage 26 - - - -<br />

Panel Type Max-Rib Ultra Max-Rib 100 Max-Rib II Max-Rib 60 Max-Rib Utility<br />

Uplift resistance, UL 580 Class 90 Class 90 Class 90 Class 90 Class 90<br />

Impact resistance, UL 2218 Class 4 Class 4 Class 4 Class 4 Class 4<br />

Fire resistance, UL 790 (ASTM E108 and NFPA 256) Class A Class A Class A Class A Class A<br />

Gage 29, 26, 24 29, 26 29, 26 29 29<br />

Panel width 36" (914 mm) 36" (914 mm) 36" (914 mm) 36" (914 mm) 36" (914 mm)<br />

Rib depth 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm)<br />

Rib spacing, on center 9" (229 mm) 9" (229 mm) 9" (229 mm) 9" (229 mm) 9" (229 mm)<br />

Warranty<br />

Finish 40 years 30 years 30 years 30 years N/A<br />

Red rust 15 years 10 years 10 years 5 years N/A<br />

Design Requirements<br />

Fade resistance X - - - -<br />

Chalk resistance X - - - -<br />

Longevity X X X - -<br />

Gloss retention X - - - -<br />

Basic shade and shelter - - - X X<br />

Residential roofing X - - - -<br />

Corrosion resistance X X X - -<br />

Budget - - - X X<br />

Approvals<br />

2004 Florida State Building Code, structural, minimum gage 29 29 29 29 29<br />

2004 Florida State Building Code, nonstructural, minimum gage 29 29 29 29 29<br />

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style<br />

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.


<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong><br />

®<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

warranties, contact a local <strong>McElroy</strong> <strong>Metal</strong>, Inc.,<br />

office or the <strong>McElroy</strong> Technical Service<br />

Department.<br />

8. Maintenance<br />

None required.<br />

9. Technical Services<br />

Factory trained service staff offers design assistance<br />

and technical support. For technical<br />

assistance, contact <strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

10. Filing Systems<br />

• Reed First Sourceª<br />

• MANU-SPECª<br />

• Additional product information is available<br />

from the manufacturer upon request.<br />

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style<br />

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!