29.03.2015 Views

METAL WALL PANELS 07 42 13 - McElroy Metal

METAL WALL PANELS 07 42 13 - McElroy Metal

METAL WALL PANELS 07 42 13 - McElroy Metal

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong><br />

®<br />

• R-Panel - A multi-use wall and roof panel<br />

used primarily in pre-engineered metal<br />

building applications<br />

• U-Panel -This wall and roof panel is also used<br />

extensively as a liner or partition panel<br />

SIZES<br />

Panel cover widths of 36" (914 mm) are standard<br />

for most wall panel products, with the exception<br />

of 5V Crimp, Multi-Cor and M-Cor. See Table 5.<br />

COLOR, FINISHES<br />

Colors shown in Table 2 are supplied standard<br />

or optional according to panel model. Consult<br />

the manufacturer’s color chart online at<br />

www.mcelroymetal.com.<br />

Galvalumeª panels are available with the<br />

Kynar 500ª/Hylar 5000ª based fluoropon 70%<br />

polyvinylidene fluoride (PVDF) paint system,<br />

which has been shown to perform better than<br />

polyester, siliconized polyester and plastisol<br />

coatings with regard to chalking and color<br />

change. See Table 3 to compare finish options<br />

by product.<br />

ACCESSORIES<br />

<strong>McElroy</strong> offers a complete selection of components<br />

and accessories, including trim, fasteners,<br />

translucent panels, closures, tape sealants, pop<br />

rivets, door track covers and roof and soffit<br />

panels. Visit www.mcelroymetal.com or consult<br />

<strong>McElroy</strong> <strong>Metal</strong> for details.<br />

LIMITATIONS<br />

Design consideration must be given to structural<br />

support, flashing and drainage systems.<br />

Consult manufacturer’s literature for detailed<br />

information on load and span tables, construction<br />

recommendations and installation<br />

procedures.<br />

4. Technical Data<br />

APPLICABLE STANDARDS<br />

American Iron and Steel Institute (AISI) - 2004<br />

Edition of the Cold Formed Steel Design Manual<br />

ASTM International<br />

• ASTM A653/A653M Standard Specification<br />

for Steel Sheet, Zinc-Coated (Galvanized)<br />

or Zinc-Iron Alloy-Coated (Galvannealed)<br />

by the Hot-Dip Process<br />

• ASTM A792/A792M Standard Specification<br />

for Steel Sheet, 55% Aluminum-Zinc Alloy-<br />

Coated by the Hot-Dip Process<br />

• ASTM B209 Standard Specification for<br />

Aluminum and Aluminum-Alloy Sheet and Plate<br />

• ASTM D2247 Standard Practice for Testing<br />

Water Resistance of Coatings in 100%<br />

Relative Humidity<br />

• ASTM E108 Standard Test Methods for Fire<br />

Tests of Roof Coverings<br />

• ASTM E119 Standard Test Methods for Fire<br />

Tests of Building Construction and Materials<br />

• ASTM E1646 Standard Test Method for<br />

Water Penetration of Exterior <strong>Metal</strong> Roof<br />

TABLE 2 COLOR<br />

Regal White<br />

Light Stone<br />

Ash Gray<br />

Roman Blue<br />

Surrey Beige<br />

Charcoal<br />

Tudor Brown<br />

Evergreen<br />

Patrician Bronze<br />

Clay<br />

Autumn Red<br />

Ivory<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

Matte Black<br />

Patina Green<br />

Dark Bronze<br />

Brite Red<br />

Regal Blue<br />

Teal<br />

Brandywine<br />

Colonial Red<br />

Sandstone<br />

Bare Galvalume<br />

Galvalume Plus<br />

Brite White<br />

Panel Systems by Uniform Static Air Pressure<br />

Difference<br />

• ASTM E1680 Standard Test Method for Rate<br />

of Air Leakage Through Exterior <strong>Metal</strong> Roof<br />

Panel Systems<br />

• ASTM G90 Standard Practice for Performing<br />

Accelerated Outdoor Weathering of<br />

Nonmetallic Materials Using Concentrated<br />

Natural Sunlight<br />

Underwriters Laboratories, Inc. (UL)<br />

• UL 263 Standard for Fire Tests of Building<br />

Construction and Materials<br />

• UL 580 Standard for Tests for Uplift<br />

Resistance of Roof Assemblies<br />

• UL 790 Standard Test Methods for Fire Tests<br />

of Roof Coverings<br />

• UL 2218 Standard for Impact Resistance of<br />

Prepared Roof Covering Materials<br />

TABLE 3 SUBSTRATE, FINISH<br />

Panel Type 5V-Crimp Mega-Rib Mini-Rib Multi-Cor M-Cor<br />

Gage 24, 26, 29 18, 20, 22, 24, 26 24, 26, 29 24, 26, 29 24, 26, 29<br />

Standard substrate, to ASTM A792 Galvalumeª Galvalumeª Galvalumeª Galvalumeª Galvalumeª<br />

Alternate substrate, to ASTM A653 N/A Galvanized Galvanized Galvanized Galvanized<br />

Coating Kynar 500ª Kynar 500ª Kynar 500ª Kynar 500ª Kynar 500ª<br />

Siliconized polyester Siliconized polyester Siliconized polyester<br />

Bare Bare Bare Bare<br />

Panel Type Multi-Rib Multi-V R-Panel U-Panel Mesa<br />

Gage 22, 24, 26 24, 26 22, 24, 26, 26 24, 26, 29 24, 26, 29<br />

Standard substrate, to ASTM A792 Galvalumeª Galvalumeª Galvalumeª Galvalumeª Galvalumeª<br />

Alternate substrate, to ASTM B209 Galvanized Galvanized Galvanized Galvanized N/A<br />

Alternate substrate, to ASTM A653<br />

Coating Kynar 500ª, Kynar 500ª, Kynar 500ª, Kynar 500ª, Kynar 500ª®<br />

Siliconized polyester Siliconized polyester Siliconized polyester Siliconized polyester<br />

Bare<br />

Bare Bare Bare<br />

Panel Type<br />

Max-Rib Ultra<br />

Gage 24, 26, 29<br />

Standard substrate, to ASTM A792<br />

Galvalumeª<br />

Kynar 500ª<br />

Coating Kynar 500ª®<br />

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style<br />

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!