<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong> ® <strong>McElroy</strong> <strong>Metal</strong>, Inc. TABLE 5 COMPOSITION & MATERIALS, PHYSICAL PROPERTIES Panel Type 5V-Crimp Mega-Rib Mini-Rib Multi-Cor M-Cor Uplift resistance, UL 580 Class 90 Class 90 - - - Impact resistance, UL 2218 Class 4 Class 4 - Class 4 Class 4 Fire resistance, UL 790 (ASTM E108 and NFPA 256) Class A Class A - Class A Class A Gage 26, 29 26, 24, 22 24, 26, 29 24, 26, 29 24, 26, 29 Panel width 24" (610 mm) 36" (914 mm) 36" (914 mm) 32" (8<strong>13</strong> mm) 37.38" (949 mm) Rib depth 7/16" (11 mm) 1 1/2" (38 mm) 3/8" (9.5 mm) 7/8" (22.2 mm) 1/2" (12.7 mm) Rib spacing 12" (305 mm) 7.2" (183 mm) 3" (76 mm) 2.67" (68 mm) 2.67" (68 mm) Warranty Limited Limited Limited Limited Limited Approvals ICC-ES Evaluation Report ER-5896, minimum gage - 24 - - - UL Construction #244, minimum gage - 26 - - - 2004 Florida State Building Code, structural, minimum gage - 26 - - - 2004 Florida State Building Code, nonstructural, minimum gage 26 26 - - - Miami-Dade Notice of Acceptance, (NOA) #<strong>07</strong>-1219.<strong>13</strong>, Expires 20<strong>13</strong>, minimum gage 26 - - - - Texas Department of Insurance Windstorm Approval, minimum gage 29 - - - - Panel Type Multi-Rib Multi-V R-Panel U-Panel Mesa Uplift resistance, UL 580 Class 90 - Class 90 - - Impact resistance, UL 2218 Class 4 - Class 4 Class 4 - Fire resistance, UL 790 (ASTM E108 and NFPA 256) - - Class A Class A - Gage 24, 26 24, 26 24, 26, 26 PB 24, 26, 29 24, 26, 29 Panel width 36" (914 mm) 35.5" (902 mm) 36" (914 mm) 36" (914 mm) 36" (914 mm) Rib depth 1 3/16" (30 mm) 1 3/16” (30 mm) 1 1/4" (32 mm) 47/64" (19 mm) 3/4" (19.1 mm) Rib spacing 12" (305 mm) 12" (305 mm) 12" (305 mm) 6" (152 mm) 9" (229 mm) Warranty Limited Limited Limited Limited Limited Approvals ICC-ES Evaluation Report ER-5896, minimum gage - - - - - UL Construction #244, minimum gage - - - - - 2004 Florida State Building Code, structural, minimum gage 26 - 26 26 - 2004 Florida State Building Code, nonstructural, minimum gage 26 - 26 - - Miami-Dade Notice of Acceptance, (NOA) #<strong>07</strong>-1219.<strong>13</strong>, Expires 20<strong>13</strong>, minimum gage - - - - - Texas Department of Insurance - Windstorm Approval, minimum gage 26 - - - - Panel Type Max-Rib Ultra Max-Rib 100 Max-Rib II Max-Rib 60 Max-Rib Utility Uplift resistance, UL 580 Class 90 Class 90 Class 90 Class 90 Class 90 Impact resistance, UL 2218 Class 4 Class 4 Class 4 Class 4 Class 4 Fire resistance, UL 790 (ASTM E108 and NFPA 256) Class A Class A Class A Class A Class A Gage 29, 26, 24 29, 26 29, 26 29 29 Panel width 36" (914 mm) 36" (914 mm) 36" (914 mm) 36" (914 mm) 36" (914 mm) Rib depth 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) Rib spacing, on center 9" (229 mm) 9" (229 mm) 9" (229 mm) 9" (229 mm) 9" (229 mm) Warranty Finish 40 years 30 years 30 years 30 years N/A Red rust 15 years 10 years 10 years 5 years N/A Design Requirements Fade resistance X - - - - Chalk resistance X - - - - Longevity X X X - - Gloss retention X - - - - Basic shade and shelter - - - X X Residential roofing X - - - - Corrosion resistance X X X - - Budget - - - X X Approvals 2004 Florida State Building Code, structural, minimum gage 29 29 29 29 29 2004 Florida State Building Code, nonstructural, minimum gage 29 29 29 29 29 SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.
<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong> ® <strong>McElroy</strong> <strong>Metal</strong>, Inc. warranties, contact a local <strong>McElroy</strong> <strong>Metal</strong>, Inc., office or the <strong>McElroy</strong> Technical Service Department. 8. Maintenance None required. 9. Technical Services Factory trained service staff offers design assistance and technical support. For technical assistance, contact <strong>McElroy</strong> <strong>Metal</strong>, Inc. 10. Filing Systems • Reed First Sourceª • MANU-SPECª • Additional product information is available from the manufacturer upon request. SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.