<strong>METAL</strong> <strong>WALL</strong> <strong>PANELS</strong> <strong>07</strong> <strong>42</strong> <strong>13</strong><br />

®<br />

TABLE 4 MEGA-RIB, MULTI-RIB, R-PANEL TECHNICAL PROPERTIES<br />

Test<br />

Air leakage, ASTM E1680<br />

APPROVALS, LISTINGS<br />

2004 Florida State Building Code, structural,<br />

non-structural<br />

ICC-ES Evaluation Report ER-5896<br />

Miami-Dade Notice of Acceptance, (NOA) -<br />

NOA #<strong>07</strong>-1219.<strong>13</strong>, Expires 20<strong>13</strong><br />

Texas Department of Insurance Windstorm<br />

Approval<br />

Underwriters Laboratories, Inc. (UL)<br />

• Multi-Rib, R-Panel, 5V-Crimp, Mega-Rib, Max-<br />

Rib, U-Panel have been approved for use in<br />

the following Underwriters Laboratories, Inc.<br />

(UL) design numbers: P225, P227, P230, P237,<br />

P250, P259, P265, P266, P268, P508, P510, P512,<br />

P514, P516, P518, P701, P711, P712, P7<strong>13</strong>, P717,<br />

P720, P722, P723, P726, P731, P732, P734, P736,<br />

P739, P740, P801, P815, P819, P824, P825, P828<br />

Visit <strong>McElroy</strong> <strong>Metal</strong>, Inc., online at www.mcelroymetal.com<br />

to obtain technical bulletins,<br />

approvals and listings by various agencies.<br />

PHYSICAL/TECHNICAL PROPERTIES<br />

See Tables 4 and 5. Technical bulletins are<br />

available online at www.mcelroymetal.com.<br />

FIRE PERFORMANCE<br />

See Table 3. For additional fire resistive assemblies<br />

and component protection information,<br />

consult <strong>McElroy</strong> Engineering Department.<br />

5. Installation<br />

PREPARATORY WORK<br />

Deliver products in manufacturer’s original,<br />

unopened, undamaged containers with identification<br />

labels intact. Inspect for damage or<br />

moisture and notify <strong>McElroy</strong> <strong>Metal</strong>, Inc., within<br />

48 hours of discovery.<br />

A forklift or crane can be used to handle<br />

unopened bundles to 25' (8 m) in length. For<br />

forklift unloading, spread forks to maximum<br />

width and place at center line weight distribution<br />

of bundle. For crane unloading, use a<br />

spreader bar to evenly distribute the bundle’s<br />

weight. Do not use cable supports as they will<br />

damage the panels.<br />

When moving individual panels, grasp<br />

panel edges and carry lengthwise, parallel to<br />

the ground. Protect the finish from scratching<br />

or abrasion.<br />

Store bundled material dry and above<br />

ground. Do not use plastic tarp, but protect<br />

from weather conditions by other means. Allow<br />

for proper air circulation to prevent moisture<br />

buildup under the tarp. Elevate one end of the<br />

bundles to allow for moisture runoff. If panels<br />

Static Pressure Air Infiltration Air Infiltration<br />

Specimen Differential Rate Rate<br />

Mega-Rib, 26 gage - 6.24 psf (- 297 Pa) - 6.24 cfm/lf 0.011 cfm/sf<br />

Mega-Rib, 26 gage + 6.24 psf (+ 297 Pa) + 6.24 cfm/lf 0.0<strong>07</strong> cfm/sf<br />

Mega-Rib, 26 gage ± 1.57 psf (± 75.2 Pa) ± 1.57 cfm/lf 0.004 cfm/sf<br />

Multi-Rib, 26 gage - 6.24 psf (- 297 Pa) 0.0<strong>07</strong> cfm/lf 0.002 cfm/sf<br />

Multi-Rib, 26 gage + 6.24 psf (+ 297 Pa) 0.004 cfm/lf 0.001 cfm/sf<br />

Multi-Rib, 26 gage - 1.57 psf (- 75.2 Pa) 0.004 cfm/lf 0.001 cfm/sf<br />

Multi-Rib, 26 gage + 1.57 psf (+ 75.2 Pa) 0.000 cfm/lf 0.000 cfm/sf<br />

R-Panel, 26 gage - 6.24 psf (- 297 Pa) 0.011 cfm/lf 0.004 cfm/sf<br />

R-Panel, 26 gage + 6.24 psf (+ 297 Pa) 0.0<strong>07</strong> cfm/lf 0.002 cfm/sf<br />

R-Panel, 26 gage - 1.57 psf (- 75.2 Pa) 0.0<strong>07</strong> cfm/lf 0.002 cfm/sf<br />

R-Panel, 26 gage + 1.57 psf (+ 75.2 Pa) 0.001 cfm/lf 0.001 cfm/sf<br />

Test Susceptibility to Leakage, FM 4471<br />

Specimen Rate Test Duration Result<br />

Mega-Rib, 24 gage Water Spray Leakage 5 gal/sf/hr 15 minutes Passed<br />

Water Depth<br />

Static Water Leakage 6" (152 mm) 7 days Passed<br />

Test<br />

Water Penetration, ASTM E1646<br />

Static Pressure Test Water<br />

Specimen Differential Rate Duration Infiltration<br />

Mega-Rib, 26 gage 12.0 psf (575 Pa) 5 gal/sf/hr 15 minutes None<br />

Multi-Rib, 26 gage 12.0 psf (575 Pa) 5 gal/sf/hr 15 minutes None<br />

R-Panel, 26 gage 12.0 psf (575 Pa) 5 gal/sf/hr 15 minutes None<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

become wet, remove all panels from bundles<br />

and dry each individually.<br />

Prolonged panel storage is not recommended.<br />

If conditions do not permit immediate<br />

installation, take extra care to protect<br />

sheets from developing rust or watermarks.<br />

Verify that site conditions are acceptable<br />

for installation. Do not proceed with installation<br />

until unacceptable conditions are corrected.<br />

Handle and store product according<br />

to <strong>McElroy</strong> <strong>Metal</strong>, Inc., recommendations.<br />

METHODS<br />

Install panels plumb, true and in correct alignment<br />

with structural framing in accordance<br />

with shop drawings and manufacturer’s<br />

instructions. Install panels in vertical installations<br />

using manufacturer’s noncorroding fasteners<br />

color matched to panel. Sight-exposed<br />

noncorroding fasteners color matched to trim<br />

are permitted. Replace products having<br />

other than minor finish damage.<br />

PRECAUTIONS<br />

Before ordering materials, have proposed<br />

installation reviewed by technical services<br />

staff. Protect installed products from damage<br />

by subsequent construction activities.<br />

Field cutting panels and driving of fasteners<br />

will create metal shavings. These must be<br />

removed from the panel surface. Failure to do<br />

so will cause rust stains on the panel surface<br />

and will void the warranty.<br />

BUILDING CODES<br />

Installation must comply with the requirements<br />

of all applicable local, state and national code<br />

jurisdictions. Current data on building code<br />

requirements and product compliance may<br />

be obtained from <strong>McElroy</strong> technical support<br />

specialists.<br />

6. Availability & Cost<br />

AVAILABILITY<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc., has 10 manufacturing<br />

facilities and 20 service centers located<br />

throughout the United States to serve the<br />

construction market. Contact <strong>McElroy</strong> <strong>Metal</strong>,<br />

Inc., for more information.<br />

COST<br />

Project-specific cost information may be<br />

obtained from a local <strong>McElroy</strong> distributor or<br />

directly from <strong>McElroy</strong> <strong>Metal</strong>, Inc.<br />

7. Warranty<br />

<strong>McElroy</strong> <strong>Metal</strong>, Inc., makes available limited<br />

warranties. For specific information regarding<br />

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style<br />

of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!