Connecting<br />

Single-Wire Connecting Cables, High Insulation<br />

Connecting Cables for Sensors with KIAG 10-32. neg. Connector<br />

Technical data<br />

Type 1967A...<br />

Connector<br />

KIAG 10-32 pos. int. – KIAG 10-32 pos. int.<br />

Length m 1 / sp* (L min = 0,5 m / L max = 10 m)<br />

Diameter mm 2,6 (ground-isolated stainless steel sheath)<br />

Deg. of protection to IEC/EN 60529 IP65 – IP65<br />

Technical data<br />

Type 1969A...<br />

Connector<br />

KIAG 10-32 pos. int. – KIAG 10-32 pos. int.<br />

Length m 1 / sp* (L min = 0,5 m / L max = 10 m)<br />

Diameter mm 2,6 (PFA with stainless steel sheath)<br />

Deg. of protection to IEC/EN 60529 IP65 – IP65<br />

Technical data<br />

Connector<br />

Type 1983AC...<br />

KIAG 10-32 pos. int. – KIAG 10-32 pos. int.<br />

Length m 0,5 / 1 / 1,5 / 2 / 3 / 5<br />

Diameter mm 2 (Viton ® )<br />

Deg. of protection to IEC/EN 60529<br />

IP65 threaded connector – IP65<br />

IP67 welded connector – IP65<br />

Technical data<br />

Type 1943A...<br />

Connector<br />

KIAG 10-32 pos. int. – Mini-Coax neg.<br />

Length m 1 / 2 / 3 / sp* (L min = 0,1 m / L max = 10 m)<br />

Diameter mm 2 (PFA)<br />

Deg. of protection to IEC/EN 60529 IP65 – IP40<br />

Technical data<br />

Type 1945A...<br />

Connector<br />

KIAG 10-32 pos. int. – Mini-Coax neg.<br />

Length m 1 / 2 / sp* (L min = 0,1 m / L max = 5 m)<br />

Diameter mm 1 (PFA)<br />

Deg. of protection to IEC/EN 60529 IP65 – IP40<br />

Data sheet 1631C_000-346<br />

Connecting Cable for Sensors with KIAG 10-32. neg. Connector, incl. Clamping Angle for Cable Coupling<br />

Technical data<br />

Type 1979A...<br />

Connector KIAG 10-32 pos. int. – Fischer Triax neg. KE 103A015-12<br />

Length m 1 / sp* (L min = 0,1 m / L max = 20 m)<br />

Diameter mm 3,2 (Viton ® )<br />

Deg. of protection to IEC/EN 60529 IP65 – IP65<br />

General technical data<br />

Operating temp. range ºC –55 ... 200<br />

Data sheet 1631C_000-346<br />

KIAG 10-32 pos. Connector with union nut<br />

KIAG 10-32 pos. int. Threaded connector (can be welded to sensor)<br />

*sp: Special length to customer specifications<br />

www.kistler.com 147