Synchronous Torque Motor <strong>DST</strong> <strong>135</strong> - <strong>315</strong><br />

Thermal sensor<br />

As standard, the motors are equipped with a thermal sensor in the stator winding. The data is evaluated in the motor<br />

controller. Additional PTCs or thermal sensors can be fitted on request. They are connected through the terminal box.<br />

Widerstand/Resistance (Ohm)<br />

2000<br />

1800<br />

1600<br />

1400<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

KTY84-130<br />

0<br />

-50 0 50 100 150 200<br />

Temperatur/Temperature (°C)<br />

The motor temperature is continuously monitored using the thermal sensor type KTY 84-130.<br />

The above shown resistance results when the sensor is supplied with a measuring current of 2 mA.<br />

Cooling circuit requirements for water-cooled motors<br />

Conditions Unit Value<br />

Maximum permissible system pressure bar 6<br />

Coolant temperature ° C 10 to 35<br />

- For Motor<br />

See diagram<br />

pH value (at 20° C) --- 6.5 to 9<br />

Overall hardness mmol/l 1.43 to 2.5<br />

Chloride - Cl -<br />

mg/l < 200<br />

Sulfate - SO4² -<br />

mg/l < 200<br />

Oil mg/l < 1<br />

Permissible particle size<br />

solid foreign bodies, particles (e.g., sand)<br />

mm < 0.1<br />

- Tmin for the coolant ≥ TAmbient (but max. coolant temperature of 35°C)<br />

- Depending on the relative humidity, the coolant temperature may be<br />

lower than the ambient temperature. The permissible coolant<br />

temperature (see diagram) depends on the relative humidity<br />

(during operation) and the ambient temperature.<br />

Values of 15% to 85% relative atmospheric humidity (non-condensing) are permissible.<br />

For example, ambient temperature 25°C → relative humidity 65%<br />

→ coolant input temperature ≥ 21°C (see diagram).<br />