No current<br />
Open Circuit<br />
(No Pressure Applied)<br />
Closed Circuit<br />
(Pressure Applied)<br />
Figure 43: Open and Closed Circuit diagram<br />
Footswitch Input<br />
10kO<br />
DC<br />
Output to Transmitter<br />
Figure 44: Pull-Down Resistor Set-up<br />
The LEMO connectors for the footswitches are similar to the<br />
FSR insoles, except they have five pins instead of four.<br />
The footswitches were purchased from B&L <strong>Engineering</strong> and<br />
came with the male LEMO connectors attached. The male LEMO<br />
connector (FGG.0B.305.CLAD52Z) is shown in Figure 45.<br />