1 - FlowVision GmbH
1 - FlowVision GmbH
1 - FlowVision GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
Electronic Flow Meter FC01-Ex-CA (compressed air/gas)<br />
Connection diagram FC01-Ex-CA for transistor and analogue outputs V1, V2, C1<br />
LIM1<br />
**<br />
C/ +<br />
1<br />
LiYCY 4x2x0.75 mm 2<br />
SGND<br />
R(Tdiff)-LO<br />
R(Tdiff)-HI<br />
IS<br />
AGND<br />
R(Tref)-LO<br />
R(Tref)-HI<br />
R(HEIZ)-HI<br />
R(HEIZ)-LO<br />
black<br />
pink<br />
grey<br />
red<br />
blue<br />
white<br />
brown<br />
green<br />
yellow<br />
* recommended<br />
** E/ -emitter terminal<br />
C/ -collector terminal<br />
*** identical with 9002/77-093-040-001<br />
# SGNDA1<br />
SGNDA2}ungrounded<br />
Apply shield on one side only.<br />
yellow<br />
3<br />
4<br />
3<br />
4<br />
/PA<br />
8x0.14 mm 2 single conductor<br />
black: 0.5 mm 2<br />
9002/22-093-040-001 ***<br />
1<br />
2<br />
9002/22-032-300-111<br />
4 3<br />
2 1<br />
9002/22-093-040-001 ***<br />
USLKG 5<br />
1<br />
2<br />
9002/13-199-225-001<br />
4 3<br />
2 1<br />
AC/DC 24 V<br />
AC/DC 24 V<br />
pink<br />
grey<br />
red<br />
blue<br />
white<br />
black<br />
brown<br />
green<br />
yellow<br />
blue<br />
brown<br />
yellow/green<br />
0.5 mm 2<br />
1 2 3 4 5 6 7 9 10 1 2 3 1 2 3 4<br />
3<br />
2<br />
1<br />
XV XSK XTF<br />
M<br />
equipotential bonding system<br />
XAS XAO XAH<br />
1 2 3 4 5 6 7<br />
1 2 3 4 5 6 7<br />
1 2 3 4 5 6 7<br />
LIM1 E/ -<br />
LIM2 C/ +<br />
LIM2 E/ -<br />
BUSY/PULSE C/+<br />
BUSY/PULSE E/ -<br />
ERROR C/ +<br />
ERROR E/ -<br />
ANA2GND<br />
ANAO2<br />
SGNDA2 #<br />
SGNDA1 #<br />
ANA1GND<br />
ANAO1<br />
SGND<br />
LifYCY 4x2x0.2 mm 2<br />
LiYCY 2x0.25 mm 2 *<br />
LiYCY 2x0.25 mm 2 *<br />
Analogue outputs:<br />
V1<br />
V2<br />
C1<br />
2x0.75 mm 2 *<br />
≥1.5 mm 2<br />
equipotential bonding monitoring head CST-Ex<br />
1.5 mm 2 - 4 mm 2<br />
Connection diagram recommended connection of pulse output<br />
Electronic signal processing<br />
Electromagnetic pulse counter<br />
XAS XAO XAH<br />
XAS XAO XAH<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Zener voltage<br />
i C<br />
t L t ON t<br />
U C<br />
U V<br />
i L ≤ 10 mA<br />
U V<br />
U C<br />
i C<br />
U V