Pipework<br />

The dimension (x) is calculated from the table below to give you a minimum<br />

effective head of 80 mm which is necessary to produce a satisfactory shower in all<br />

conditions.<br />

Plumbing Schematic Diagram<br />

A<br />

X<br />

B<br />

Example!<br />

The example below is based on the diagram above with 15 mm<br />

pipework, A = 1.5 m, B = 0.75 m.<br />

Size<br />

Quantity<br />

Head Loss (mm)<br />

15 mm Pipe<br />

22 mm Pipe<br />

(A) 1.5 + (B) 0.75 = 2.25 x 120 270<br />

(A) + (B) = x 20<br />

15 mm Elbow<br />

Number of Elbows<br />

1<br />

x 55<br />

55<br />

22 mm Elbow<br />

Number of Elbows<br />

x 15<br />

Minimum Effective Head<br />

(x) mm<br />

80<br />

405<br />