1. DISPLAY AND OPERATION B–<strong>63505EN</strong>/<strong>01</strong><br />

1.4<br />

ALARM HISTORY<br />

SCREEN<br />

1.4.1<br />

General<br />

Alarms generated in the NC are recorded. The latest 50 alarms generated<br />

are recorded. The 51th and former alarms are deleted.<br />

1.4.2<br />

Screen Display<br />

(1)Press key .<br />

MESSAGE<br />

(2)Press soft key [HISTRY] and an alarm history screen is displayed.<br />

(3)Other pages are displayed by<br />

PAGE<br />

or<br />

PAGE<br />

key.<br />

ALARM HISTORY<br />

O1234 N12345<br />

97/04/18 20:56:26<br />

506 OVERTRAVEL : +X<br />

97/04/18 19:58:11<br />

000 TURN OFF POWER<br />

97/04/18 19:52:45<br />

000 TURN OFF POWER<br />

97/04/18 19:48:43<br />

300 APC ALARM : X–AXIS ZERO RETURN REQUEST<br />

97/04/18 18:10:10<br />

507 OVERTRAVEL : +B<br />

[ ALARM ][ MSG ][ HISTRY ][ ][(OPRT)]<br />

1.4.3<br />

Clearing Alarm History<br />

(1)Press soft key [(OPRT)].<br />

(2)Press soft key [(CLEAR], then the alarm history is cleared.<br />

1.4.4<br />

Alarm Display<br />

When an external alarm (No. 1000 to 1999) or a macro alarm (No. 3000<br />

to 3999) is output, the alarm history function can record both the alarm<br />

number and message if so specified in the following parameter. If<br />

recording of the message is not set or if no message is input, only an<br />

external alarm or macro alarm is displayed.<br />

3112<br />

#7<br />

#6 #5 #4 #3<br />

EAH<br />

#2 #1 #0<br />

[Data type] Bit<br />

#3 (EAH) The alarm history function:<br />

0 : Does not record the messages output with external alarms or macro<br />

alarms.<br />

1 : Records the messages output with external alarms or macro alarms.<br />