J-3999.7-FM Flood Risk Assessment & SUDS Design, Cave Farm, Nr Pitney, Somerset V2<br />

___________________________________________________________________________________________<br />

9.0 CONCLUSIONS AND RECOMMENDATIONS<br />

The study has investig<strong>at</strong>ed the mechanisms for flooding <strong>at</strong> the <strong>proposed</strong> Cave Farm Solar<br />

Park site and has identified th<strong>at</strong> the <strong>development</strong> is not <strong>at</strong> any direct risk of flooding.<br />

This study has investig<strong>at</strong>ed the impact th<strong>at</strong> the <strong>development</strong> will have on runoff r<strong>at</strong>es from<br />

the site. It has been shown th<strong>at</strong> the impermeable area introduced across the site is very small<br />

rel<strong>at</strong>ive to the size of the site and as such will have limited impact on the runoff r<strong>at</strong>es from<br />

the site. A swale system has been <strong>proposed</strong> to allow the interception and infiltr<strong>at</strong>ion of the<br />

flows from these areas. A pragm<strong>at</strong>ic approach has been used to design the swale system to<br />

promote infiltr<strong>at</strong>ion across the site.<br />

If the recommend<strong>at</strong>ions made in this report are followed during the <strong>development</strong> of the site,<br />

there will be a reduction in the discharge r<strong>at</strong>e to any adjacent w<strong>at</strong>ercourse, and no extra risk<br />

of flooding to properties loc<strong>at</strong>ed in the area.<br />

On the basis of this report and by reference to EA flood maps, it is concluded th<strong>at</strong> the site is<br />

loc<strong>at</strong>ed within Flood Zone 1 and is therefore not <strong>at</strong> any direct risk of flooding. The N<strong>at</strong>ional<br />

Planning Policy Frame work and associ<strong>at</strong>ed Technical Guidance therefore st<strong>at</strong>es ‘All uses of<br />

land are appropri<strong>at</strong>e in this zone’ from a flooding perspective. Consequently, with regard to<br />

flood risk, the <strong>proposed</strong> <strong>development</strong> is entirely appropri<strong>at</strong>e in this area.<br />

P:\Job Files 3900-3999\J-3999-FM AEE Flood Risk Assessments\J-3999.7-FM Cave Farm\Report V2<br />