5.3 CONNECTING MORE THAN ONE DETECTOR<br />

IMPORTANT: This must always be carried out with the SMOKE<br />

DETECTOR 1 cable unplugged from the JUNCTION<br />

BOX 3 !<br />

Up to 10 SMOKE DETECTORS can be c<strong>on</strong>nected to<br />

the system.<br />

Additi<strong>on</strong>al SMOKE DETECTORS are c<strong>on</strong>nected in a “daisy<br />

chain” to the first detector and to each other, see the<br />

diagram below:<br />

CONNECTING ADDITIONAL SMOKE DETECTORS:<br />

power to detector head<br />

A<br />

power to detector head<br />

R56<br />

R56<br />

D22<br />

IMPORTANT!<br />

when c<strong>on</strong>necting more than<br />

<strong>on</strong>e detector head, this resistor<br />

(R56) must be removed from<br />

each detector head EXCEPT<br />

the last <strong>on</strong>e in the line.<br />

D22<br />

IMPORTANT!<br />

when c<strong>on</strong>necting more than<br />

<strong>on</strong>e detector head, this resistor<br />

(R56) must be removed from<br />

each detector head EXCEPT<br />

the last <strong>on</strong>e in the line.<br />

C<br />

B<br />

c<strong>on</strong>nect red sleeved<br />

wire to<br />

CONN6<br />

c<strong>on</strong>nect red sleeved<br />

wire to<br />

CONN6<br />

plain wire to<br />

plain wire to<br />

D<br />

A<br />

B<br />

C<br />

D<br />

End of line detector screw terminal circuit board.<br />

10m cable with plug (standard supply)<br />

Plug into ‘Detector’ socket <strong>on</strong> juncti<strong>on</strong> box<br />

Interc<strong>on</strong>nect cable (opti<strong>on</strong>al)<br />

C<strong>on</strong>tinued On Page 19<br />

18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!