ASSAY METHOD:<br />
PRODUCTIVITY:<br />
WALK AWAY:<br />
OPERATING MODE:<br />
DISPENSING SYSTEM:<br />
WASHING SYSTEM:<br />
INCUBATION / REACTION:<br />
ALIQUOTE SYSTEM:<br />
THERMOSTAT:<br />
READER:<br />
SAMPLES:<br />
REAGENTS:<br />
CALIBRATION:<br />
QUALITY CONTROL:<br />
PATIENT FILE:<br />
SOFTWARE:<br />
HOST CONNECTION:<br />
OPERATING CONDITIONS:<br />
POWER SUPPLY:<br />
CONSUMPTION:<br />
SAFETY STANDARDS:<br />
ELECTROMAGNETIC COMPATIBILITY:<br />
IVD:<br />
DIMENSIONS AND WEIGHT:<br />
FIA<br />
TECHNICAL FEATURES<br />
Fully automated Random Access System in fluoroimmunoassays<br />
Up to 120 tests/hr<br />
400 tests<br />
Continuous loading of reagents, samples, calibrators, controls, pre-dilution cuvettes, reaction cuvettes and<br />
substrate. Simultaneous management of all the methods. Automatic substitution of the finished common<br />
reagents by continuous <strong>access</strong>. Separated solid and liquid waste station<br />
XYZ type with 2 independent needles and 2 500 µL syringes. (Optional) disposable tips. Capacitive<br />
coagulation level sensor (sensitivity 150 µL). Precision CV < 3% volume from 5 to 100 µL<br />
Two washer stations used for sedimentation, washing of the cuvettes and dispensing of the substrate<br />
180 positions’ station where the incubation and the reaction take place in orbital shake and at controlled<br />
temperature (37°C)<br />
On board for STAT<br />
Dry, at 37°C with ± 0.5°C precision. Heating up time 5’<br />
Fluorescence reading through led source with excitation at 370nm and revelation at 450nm<br />
Up to 120 samples on board (6 racks, 20 positions each). Continuous loading for routine and STA<br />
Primary, secondary tubes (12/16 mm) and paediatric cuvettes handling Positive identification by barcode<br />
reader Automatic predilution (56 positions) Automatic aliquote system on board Automatic dilution of outside<br />
range samples Reflex test<br />
Dedicated reagent pack for 50,100,150 or 200 tests 12 weeks stability on board; 20 different methods on<br />
board (up to 200 determinations each) 20 barcode identifiable positions for reagents Refrigerated reagent<br />
plate (4-8°C) Continuous loading without interruption to workflow<br />
Single use calibrator pack Positive calibrator identification via barcode reader; Two point calibration on Master<br />
Curve plus two control points Up to 4 weeks calibration stability<br />
Internal Quality Control management applying Westgard rules and Levy-Jennings charts<br />
Search for patients by ID, name, data and test Printing session report Printing patient report<br />
Multitask and Multilanguage interface Operating System: Windows XP or superior Touch Screen Monitor<br />
Bidirectional with serial port (RS232 interface), Web, ASTM<br />
15 – 32°C Temperature while operating; Maximum relative humidity 80%<br />
100 – 240 VAC; 50 – 60 Hz<br />
600 VA<br />
Directive 2006/95/EC<br />
Directive 2004/108/EC<br />
Directive 98/79/EC<br />
L.143 X W.78 X H.145 cm - 200 Kg<br />