random access device - Radim S.p.A.
random access device - Radim S.p.A.
random access device - Radim S.p.A.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Screenplus<br />
Upon Request<br />
CLINICAL CHEMISTRY<br />
CLINICAL CHEMISTRY EQUIPMENT<br />
The Clinical Chemistry photometer ScreenPlus is an instrument that can be easily placed in any type<br />
of clinical laboratory. It effects readings of end point, kinetic, fixed time and differential reaction, in<br />
absorbance and concentration, storage of 199 methods with possibility of programming each method<br />
with type of reaction, wavelength, working temperature, reading unit, normal values, incubation time<br />
and reading intervals. Reading is effected by single cuvette 10x10 mm., macro or semi micro, in<br />
mono and bi-chromatism. The instrument is completed with a liquid crystal display, 9 position<br />
thermostatic plate for cuvettes, a touch pad alphanumerical keyboard and an incorporated graphic<br />
printer for the print out of data, calibration and kinetic curves.<br />
71<br />
cod. 01060381SM<br />
TECHNICAL FEATURES<br />
READING METHODS: Absorbance, end point, kinetic, fixed time and differential reaction with standard<br />
(from 1 to 9) or K Factor<br />
OPTICAL SYSTEM: Halogen Lamp 20 W; 6 interferential filters, 340, 405, 505, 546, 578, 630 nm, with an accuracy<br />
of +/- 2 nm, band width of 8 nm and two free positions for optional filters;<br />
Solid state optical sensor; Photometric linearity from - 0.3000 to 2.9999 O.D. ;<br />
Photometric accuracy:+/-2%at 0.700O.D.<br />
READING CELL: 80 µL flow through cell; Optical path 10 mm; Minimum reading volume: 400 µL;<br />
Automatic withdrawal and wash cycle by means of peristaltic pump;<br />
Temperature regulation from 20°C to 45°C with 1°C resolution, with Peltier effect element;<br />
possibility to directly read open macro and semi-micro cuvettes;<br />
9 wells for open cuvette incubation<br />
SOFTWARE: All the photometer functions are managed by a FLASH memory microprocessor which can be<br />
up-dated through the serial output.; 199 programs;<br />
Automatic print out of results; Print out of the calibration and kinetic curves;<br />
Fitting types: linear, point to point and cubic; Pathological warnings;<br />
Functionality autodiagnosis<br />
USER INTERFACE: Functional alphanumerical keyboard; Alphanumerical liquid crystal display with four, twenty<br />
character lines; Thermal graphical printer with 192 dots per line RS 232 serial port<br />
POWER SUPPLY: 230/115 VAC, 50 - 60 Hz, 83 VA<br />
SAFETY STANDARDS: Directive 2006/95/EC<br />
ELECTROMAGNETIC COMPATIBILITY: Directive 2004/108/EC<br />
IVD: Directive 98/79/EC<br />
DIMENSIONS AND WEIGHT: L. 30 x W. 30 x H. 36 cm; 9,5 Kg