10.07.2015 Views

Engineering Manual o.. - HVAC.Amickracing

Engineering Manual o.. - HVAC.Amickracing

Engineering Manual o.. - HVAC.Amickracing

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INDIVIDUAL ROOM CONTROL APPLICATIONSHEAT PUMPSGENERALA heat pump is a r efrigeration system tha t pr ovides bothheating and cooling within the same unit. In the heating mode,the pump deli vers heat fr om a hea t sour ce to the conditionedspace. In the cooling mode , the pump r emoves heat fr om aspace and transfers it to a heat sink. Heat pumps use standardrefrigeration components (compr essor, expansion v alve,evapor ator, and condenser) and a r eversing valve to r everserefrigerant f low thr ough the coils. A refrigerant r eversing valveswitches at chang eover to con vert the condenser to an e vapor atorand vice v ersa.Figur e 36 shows heat pump c ycles. In the cooling c ycle,refrigerant f low uses the outdoor hea t exchang er coil as thecondenser to reject heat from the space, and the indoor coil asthe evapor ator. In the hea ting cycle, flow of air and r efrigerantis reversed making the outdoor coil the sour ce of heat. Theindoor coil becomes the condenser and pr ovides hea t for thespace. When outdoor air temper atur es ar e too cold to pr ovideenough hea t tr ansfer, electr ic resistance hea ting elements canbe used to pr ovide supplemental hea t. An alter native method isto r everse indoor and outdoor airf low acr oss the coils andelimina te the r eversing valve.Heat pumps ar e typicall y classified by the hea t sour ce at the“outdoor” coil. The common air -to-air hea t pump uses outdoorair as its hea t sour ce dur ing the hea ting cycle. A water -to-airheat pump uses w ater as the hea t sour ce dur ing the hea tingcycle. The water suppl y may be a well or a lak e. In the coolingmode, the outdoor coil r ejects hea t and the air or w ater becomesthe heat sink.In commer cial applica tions, a closed-loop or r unar ound w atersuppl y may serve multiple units (F ig. 37). This system r elies onload di versification. Some units ma y be cooling while other z onesoper ate in the hea ting cycle. In this case , the water loop is a sour ceto heating units and a sink to cooling units, transferring heat fromone to the other . Water-loop temper atur es ar e maintained betw een21°C and 32 °C to pr ovide an adequa te hea t sour ce or hea t sink. Acentr al boiler to gether with a c hiller and/or cooling to wer temperthe water in the loop dur ing peak hea ting and cooling per iods.For a discussion of centr al r egulation and contr ol of water pumphydr onic loops, refer to Chiller , Boiler, and Distr ibution SystemContr ol Applica tions section.HEATPUMPTHERMOSTATCOMPRESSORCHILLER ORCOOLINGTOWERREFRIGERANTREVERSINGVALVEBOILERINDOORCOILOUTDOORCOILPUMPEXPANSIONVALVE FORCOOLINGC3022INDOORCOILCHECKVALVECOOLING CYCLECOMPRESSOREXPANSIONVALVE FORHEATINGCHECKVALVEHEATING CYCLEREFRIGERANTREVERSINGVALVEOUTDOORCOILC3021Fig. 36. Refrigerant Flow in Heat PumpCooling and Heating Cycles.OPERATIONFig. 37. Heat Pump Closed-Loop System.Small and medium-sized heat pumps usually heat and coolindoor air and ar e contr olled fr om a space ther mosta t. Lar geheat pumps usuall y pr ovide war m and c hilled water and ar econtr olled by a chilled water temper atur e contr ol.Space ther mosta ts ar e two-position and usuall y multista ge.They typicall y pr ovide automa tic chang eover, switching theheat pump between heating and cooling as required to maintainspace temper atur e. The first sta ge of the ther mosta t cycles thecompr essor. If the system is in a hea ting mode , additionalthermostat heating stages will bring on supplementary resistanceheat if the heat pump cannot meet the load. In the cooling mode,ther e is only one sta ge tha t cycles the compr essor. If desir ed,chang eover betw een hea ting and cooling can be man ual r atherthan automa tic. The ther mosta t can ha ve separ ate hea ting andcooling settings or a single setting with a f ixed deadbandbetween heating and cooling.ENGINEERING MANUAL OF AUTOMATIC CONTROL 421

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!